background image

24

25

1

+

direct to function 

selection wheel:

on/off -

bromicharge -

boost level -

maintenance -

status and messages

mode selection 

wheel:

in.clear icon

sanitization mode

(only available if the system detects a connected in.clear water sanitization system)

To select the sanitization mode, slide the left wheel up or down until the in.clear icon menu is 

highlighted in the middle.
In the sanitization page you can access the following:
• in.clear on/off  

• boost level 

• bromicharge  

• maintenance level

To select an item, slide the right wheel until the desired icon is highlighted in the middle.

on/off

bromicharge™ level

turn in.clear ON - 

Step 1 (icon red)

Slide the right wheel until the power on/off icon is 

highlighted in the middle. Press the icon to turn 

in.clear on.

turn in.clear OFF - 

Step 2 (icon yellow)

Press icon for 5 seconds to confirm power off.

To perform a water test, slide the right wheel until 

the add BromiCharge™ icon is highlighted in the 

middle. 
There is no need to add sodium bromide if the 

indicator is in the green zone.
When adding sodium bromide, the gauge 

indicator will gradually shift to the right. When 

adding clean water to the spa, the indicator will 

shift to the left.
In order to achieve the proper level, start pumps 

and add 227g (.5 lb) of BromiCharge™ at a time 

and always allow 5 minutes for the gauge to react 

before adding more sodium bromide.

When performing a test, the BromiCharge™ 

gauge indicates the approximate sodium bromide 

level of the spa water. 

The green zone in the center area of the gauge 

should be targeted for optimal performance.

turn in.clear OFF -  

Step 3 (icon green)

Press the icon to turn off the in.clear.

1

+

boost level

maintenance level

Use a test kit to check the bromine level. It should 

be between 3-5 ppm. If the bromine level stays 

within that range for 3 consecutive days, your 

maintenance level is well adjusted.

modify the boost level

Boost mode is activated automatically 5 minutes 

after starting a pump. Boost mode increases 

the bromine generation rate to keep the water 

clear, clean and soft. As a rule of thumb, its level 

correspond to the number of bathers.
To modify the boost level, slide the right wheel 

until the boost icon is highlighted in the middle 

and use the up or down arrow keys to adjust the 

level.
Click on the the level icon to confirm your 

selection.

modify the maintenance level

To verify or modify the maintenance level, slide 

the right wheel until the maintenance icon is 

highlighted in the middle.
The recommended maintenance level is 12.
Use the up or down arrow keys to adjust the level.
Note that the level can be adjusted by increment 

of 2 using the up and down arrow keys.

Please note that it is not recommended to change 

the maintenance level at steps greater than 2.  

A confirmation will be asked by the system if  

you do.
If you do, retest the bromine level the day after.  

If the bromine is not in the 3-5 range and is 

higher than 5 ppm, decrease the maintenance 

level. If the bromine is lower than 3 ppm, increase 

it. Repeat until the test reads a bromine level in 

the 3-5 range.

Содержание Control in.k1000

Страница 1: ...01 Control in k1000 Hot Tub Manual...

Страница 2: ...g your spa Within in this manual are important start up guidelines and maintenance procedures as well as safety precautions that must be followed to ensure the prolonged life of your spa and the safet...

Страница 3: ...quirements Section 9 Prepare your spa for holiday Section 1 Important safety information Section 7 Maintenance Section 4 Delivery of your spa Section 10 Spa winterization Section 2 Pre installation se...

Страница 4: ...isk of Electrical Shock Do not leave compartment door open 9 CAUTION Risk of Electrical Shock Replace components only with identical components 10 WARNING Prevent Electrocution Do not connect any auxi...

Страница 5: ...r any future maintenance ideally 600mm If this is not practical then the hot tub must be emptied of water prior to our visit so that the hot tub can be moved to allow access Think about When deciding...

Страница 6: ...pply with any other appliances The hot tub should be appropriately protected by a sufficiently rated MCB mains circuit breaker and should cover the maximum amperage pull of the hot tub plus 25 to allo...

Страница 7: ...mended water level as indicated by the minimum water level in your hot tub Low water levels can cause damage to the pump and heater element so is good practice to top up your spa on a weekly basis If...

Страница 8: ...em is off in stream 2 audio system is on in stream 2 audio system is off in mix is installed system is connected to wifi system is not connected to wifi All on or all off key one touch activation dire...

Страница 9: ...heating settings Choose set or modify one of the 5 suggested modes depending on your needs at any given time Away from home In this mode the spa will always be in economy the set point will be reduce...

Страница 10: ...ou can change the hour minute and time format Simply swipe up and down the column you want to change and select the desired value When done touch the calendar icon at the right of the screen display o...

Страница 11: ...alized drills is set during the drill creation and can be edited from the Training Drills selection page From this page you can also access the following training drills selection swim settings To sel...

Страница 12: ...ep at low intensity Power This training drill will perform a pyramid program where the intensity will progressively increase until the maximum is reached It will then decrease progressively to end at...

Страница 13: ...ximate sodium bromide level of the spa water The green zone in the center area of the gauge should be targeted for optimal performance turn in clear OFF Step 3 icon green Press the icon to turn off th...

Страница 14: ...ouching the light bulb icons located each side of the intensity bar synchronizing zones The synchronization desynchronization icon allows you to match the color of the selected zone with the other zon...

Страница 15: ...at least every 6 9 months In addition to putting a severe strain on your hot tub s pump worn out filters are unable to properly trap contaminants Tip 2 Basic Rinsing Your spa s filter should be given...

Страница 16: ...r load Non Chlorine Shock These shocks won t disinfect the water so if you are worried about bacteria this isn t the right one to use They are however great at oxidizing other contaminants and cleanin...

Страница 17: ...in But if you didn t lose much through evaporation and your spa is still nearly full you ll need to remove some water so you can reduce the concentration of sanitizer with fresh water This will be eno...

Страница 18: ...ou decide to use a sub pump make sure when you re finished to remove the drain plug from your hot tub anyway to drain of as much of the water as possible 4 If you use the drain plug the hot tub will a...

Страница 19: ...Call for spa service if the high limit thermostat has tripped Spa won t heat even while the jets and lights operate Air lock was created after filling the spa Blocked filters Failed air circulation p...

Страница 20: ...38 Superior Spas ltd Unit 6 Station Rd Brimington Chesterfield S43 1JU t 44 0 1246 559071 e info superiorspas co uk w superiorspas co uk...

Отзывы: