PARTS 

MODELS 36", 42", AND 50" 

Catalog numbers are included for convenience.

1

21

20

5

6

7

10

9

11

12

13

16/17

15

14

8

24

23

3

25

18

2

22

19

4

MODEL

CATALOG NO.

WRT6036RS

F0600

WRT6036IS

F0601

WRT6036RH

F0602

WRT6036IH

F0603

WRT6042RS

F0604

WRT6042IS

F0605

WRT6042RH

F0606

WRT6042IH

F0607

WRT6050RS

F0608

WRT6050IS

F0609

WRT6050RH

F0610

WRT6050IH

F0611

Содержание WRT6036IH

Страница 1: ...vent free gas log heater approved to ANSI Z21 11 2 standard FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before instal...

Страница 2: ...anufacturer s instructions with the insert specifically state this fireplace has been tested for use with this insert FOR YOUR SAFETY Do not store or use gasoline or any other flammable vapors or liqu...

Страница 3: ...king causes and troubleshooting WARNING BURNINGIMPROPERFUEL I E CHAR COAL CAN RESULT IN CARBON MONOXIDE POISON ING WHICH MAY LEAD TO DEATH Carbon Monoxide Poisoning Early signs of carbon monoxidepoiso...

Страница 4: ...20 1 4 515 mm Ref 14 1 2 369 mm 4 1 2 115 mm 10 1 2 267 mm 9 1 2 242 mm 3 1 2 89 mm 4 1 2 115 mm 45 1 8 1159 mm 36 915 mm 30 762 mm 49 1245 mm 67 1702 mm 11 280 mm 7 178 mm 61 1550 mm 1 26 mm 11 280 m...

Страница 5: ...85 mm Ref 21 3 4 553 mm 15 3 4 400 mm 4 3 8 112 mm 10 1 2 267 mm 9 1 2 242 mm 3 1 2 89 mm 4 1 2 115 mm 51 1 8 1299 mm 42 1067 mm 30 762 mm 49 1245 mm 67 1702 mm 11 280 mm 7 178 mm 61 1550 mm 1 26 mm 1...

Страница 6: ...7 178 mm 67 1702 mm 61 1550 mm 58 1474 mm 49 1245 mm 30 762 mm 9 1 2 242 mm 10 1 2 267 mm 13 331 mm 50 1270 mm 34 3 8 874 mm 38 1 2 978 mm 28 1 2 724 mm 17 5 8 448 mm 4 3 8 112 mm 19 1 4 489 mm 21 3...

Страница 7: ...ight of termination assembly at level of the flue gas outlet see Figure 15 page 12 FRAMING 1 Frame opening for fireplace using dimensions shown in Figures 4 and 5 2 If fireplace is to be installed dir...

Страница 8: ...t Ember Protector Fireplace Front Raised Hearth Fireplace Front Elevated Ember Protector Ember Protector Seal Gap Hearth Extension MANTELS A mantel may be installed if desired see Figure 7 Woodwork su...

Страница 9: ...Pipe Section 34 5 8 880 mm 48 12DM 48 12HT Pipe Section 46 5 8 1185 mm RLT 12D RLT 12HT Round Termina tion 7 3 4 197 mm STL 12D Square Chase Top with Slip Section 7 178 mm to 15 381 mm The lineal gain...

Страница 10: ...t be secured with two screws on the outer pipe only see Figure 10 Do not penetrate the inner stainless Figure 11 Ceiling Support Pipe 12S 12DM 2 51 mm Min Straps Straps Straps Straps Detail A Return E...

Страница 11: ...pacer with Attic Space Above Ceiling Existing Ceiling Frame Firestop Spacer Screws or Staples Min of 8 Firestop Spacer Screws or Staples Min of 8 Existing Ceiling Frame IMPORTANT NOTICE When penetrati...

Страница 12: ...e Waterproof Caulk Storm Collar Flashing FLASHING INSTALLATION V6F 10DM OR V12F 10DM Determine the flashing to be used with the roof opening chart Slide flashing over pipe until base is flat against r...

Страница 13: ...ion be sure to provide adequate distance between terminations to prevent smoke spillage from one termination to another We suggest that terminations be separated at least 24 center to center and stack...

Страница 14: ...ination to Chase Top Flashing with Sheet Metal Screws Figure 23 Installing Termination Cap 1 Noncombustible Spacer Note Do Not Seal Ventilation Openings 1 Space Chase Facia 1 4 Screen Chase Top Sheet...

Страница 15: ...h storm collar where chimney pierces opening in flash ing Caulk where storm collar touches outer chimney pipe see Figure 29 Figure 26 Constructing Chase Top Flashing As Required 2 Collar 16 1 2 Diamet...

Страница 16: ...ch firebrick wall Angle the wall into the fireplace opening and into the slots on the side of the hearth Figure 32 then tilt the top of the panel toward the firebox sur round 3 Secure the firebrick wa...

Страница 17: ...ure This will keep the mixture moist and it will not dry out before use 5 Grout all joints where two firebrick walls come together 6 Using a trowel remove excess grout mixture by moving trowel in the...

Страница 18: ...eated WARNING Whenusingadecorativeventedgaslog the damper must be removed or permanently locked in the fully open position and the glass doors must be in the fully open position Gas line hook up shoul...

Страница 19: ...TALLING GLASS DOORS Spring clips have been installed but some adjustments may be needed Install the doors using the following steps 1 With bifold doors completely folded insert bottom pivot pin into p...

Страница 20: ...ould not be burned in this fireplace Always keep the fire well back from the doors and never allow flames to contact the glass WARNING Fireplaces equipped with glass doors should be operated only with...

Страница 21: ...g agency for use with this fireplace may be used if installed in accordance with the instructions by its manufacturer A locally fabricated shroud may be used with IHP Shroud Leg Spacer Kit SLK in acco...

Страница 22: ...ed for convenience 1 21 20 5 6 7 10 9 11 12 13 16 17 15 14 8 24 23 3 25 18 2 22 19 4 MODEL CATALOG NO WRT6036RS F0600 WRT6036IS F0601 WRT6036RH F0602 WRT6036IH F0603 WRT6042RS F0604 WRT6042IS F0605 WR...

Страница 23: ...ace Top Assembly 50 1 10 J6997 Standoff 4 11 Fireplace Surround Assembly 1 12 J4362 Clearance Spacer 6 13 J5329 Fireplace Handle Bracket 4 14 J6900 Outside Air Cover Plate 2 15 J6934 Gas Conduit Cover...

Страница 24: ...COULD CAUSE INJURY USE ASSISTANCE WHEN MOVING OR LIFTING 1 6 4 8 7 3 2 5 7 7 7 8 9 PARTS MODELS 36 42 AND 50 Picture may vary from actual Note See pages 25 and 26 for part numbers MODEL CATALOG NO WR...

Страница 25: ...81 Rear Herringbone 50 Red 1 5 J6054 Right Stacked 36 Red 1 J6061 Right Herringbone 36 Red 1 J6462 Right Stacked 42 Red 1 J6468 Right Herringbone 42 Red 1 J6476 Right Stacked 50 Red 1 J6484 Right Herr...

Страница 26: ...ar Herringbone 50 Ivory 1 5 J6055 Right Stacked 36 Ivory 1 J6062 Right Herringbone 36 Ivory 1 J6463 Right Stacked 42 Ivory 1 J6469 Right Herringbone 42 Ivory 1 J6477 Right Stacked 50 Ivory 1 J6485 Rig...

Страница 27: ...i Temp Double Wall Pipe Snap Lock F0954 18 12HT 18 Section Hi Temp Double Wall Pipe Snap Lock F0955 24 12HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0956 36 12HT 36 Section Hi Temp Double Wall P...

Страница 28: ...creen F0960 RLT 12HT Hi Temp Round Top Termination with Louvered Screen FIRESTOP THIMBLE F0944 FST10 Firestop Thimble LABEL UL127 50PK WARNING HOT Fire Risk Insulation and combustibles must not touch...

Страница 29: ...nditions inadequate chimney heights adversewindconditionsand orunusualenvironmental factors or conditions beyond our control take into account all variables within the installation and install the app...

Страница 30: ...ance The best location to install your appliance is determined by consid ering the location of windows doors and the traffic flow in the room where the appliance is located allowing space in front of...

Страница 31: ...be subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with a...

Страница 32: ...6595 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult yo...