background image

SuperiorFireplaces.us.com

901009-00_NC

14

Gas line hook up should be done by your supplier or a qualified 

service person.

Note: Before you proceed, make sure your gas supply is turned off.

Use only a 1/2" black iron pipe and appropriate fittings. 
1.  Remove knockout indentation on refractory or firebrick wall lo-

cated above refractory hearth floor. Knockout indentation must be 

firmly tapped with any solid object such as a 1/2" dowel until it is 

released. Remove fragmented portions of refractory (see Figure 

18).

2.  Remove gas line cover plate located on either side of fireplace and 

pull out insulation from gas line conduit sleeve. Save insulation for 

reuse. Replace screws.

3.  Run a 1/2" black iron gas line into fireplace through the rear at gas 

line conduit sleeve (if using a raised platform, add height). Provide 

sufficient gas line into fireplace chamber for fitting connection (see 

Figure 19). 

 

Note: Secure incoming gas line to wood framing to provide rigidity 

for threaded end.

4.  Repack insulation around gas line and into sleeve opening. Seal any 

gaps between gas line and refractory knockout hole with refractory 

cement or commercial furnace cement, Install the gas appliance or 

cap-off gas line if desired.

Figure 18 - Gas Line Access

Seal 

Opening 

with 

Refractory 

Cement

Outside of 

Fireplace

Gas Line 

Conduit

Repack 

Insulation

Incoming 

1/2" Black 

Iron Pipe

Side 

Firebrick 

Finished 

Side

Provide Enough 

Threaded End 

for Fitting 

Connection

Figure 19 - Gas Line Installation

Side 

Firebrick 

Finished 

Side

Brick with 

Access Hole

Outside of 

Fireplace

Gas Line 

Conduit

Insulation

Gas 

Conduit 

Cover

1/2" Dowel

Remove 

Knockout

GAS LINE INSTALLATION

 CAUTION: All gas piping and connections must be 

tested for leaks after the installation is completed. 

After ensuring that the gas valve is on, apply soap and 

water solution to all connections and joints. Bubbles 

forming show a leak. Correct all leaks at once. DO NOT 

USE AN OPEN FLAME FOR LEAK TESTING AND DO NOT 

OPERATE ANY APPLIANCE IF A LEAK IS DETECTED. 

LEAK TESTING SHOULD BE DONE BY A QUALIFIED 

SERVICE PERSON.

 WARNING: Do not operate an unvented gas log set in 

this fireplace with the chimney removed.

If you install a decorative gas appliance (vented gas log), the decora-

tive gas appliance must comply with the 

Standard for Decorative Gas 

Appliance for Installation in Solid Fuel Burning Fireplaces, ANS 

Z21.60 or Z21.84 

and shall also be installed in accordance with the 

National Fuel Gas Code, ANSI  7223NFPA 54 latest edition

.

If you wish to install an unvented (vent-free) gas log set, only unvented 

gas log sets which have been found to comply with the standard for 

unvented room heaters, ANSI Z21.11.2 are to be installed in this 

fireplace.

 WARNING: If the fireplace has been used for wood 

burning, the firebox and chimney must be cleaned 

of soot, creosote and ashes be a qualified chimney 

cleaner. Creosote will ignite if heavily heated.

 WARNING: When using a decorative vented gas log, 

the damper must be removed or permanently locked in 

the fully open position and the glass doors must be in 

the fully open position.

Содержание VRT6036

Страница 1: ...ult causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instru...

Страница 2: ...material on or near the appliance Never place any objects in the firebox or on logs Firebox front and screen becomes very hot when run ning firebox Keep children and adults away from hot surfaces to avoid burns or clothing ignition Firebox will remain hot for a time after shutdown Allow sur faces to cool before touching Carefully supervise young children when they are in the room with firebox WARN...

Страница 3: ... firebox with care Follow all local codes In the absence of local codes use the latest edition of The National Fuel Gas Code ANSI Z223 1 NFPA 54 Firebox must be electrically grounded in accordance with the National Electrical Code ANSI NFPA70 latest edition Available from American National Standards Institute Inc 25 West 43rd Street 4th floor New York NY 10036 National Fire Protection Association ...

Страница 4: ...0_NC 4 PRODUCT SPECIFICATIONS 36 MODEL Figure 1 36 Model VRT6036 Picture may vary from actual firebox 30 1 2 29 30 11 1 8 54 1 2 7 7 8 7 36 45 1 8 35 16 97 16 50 365 16 7 3 8 111 8 3 3 4 4 7 8 36 HEARTH 1 1 4 20 1 4 Ref 35 1 4 19 22 1 2 ...

Страница 5: ...RODUCT SPECIFICATIONS Continued 42 MODEL Figure 2 42 Model VRT6042 Picture may vary from actual firebox 4 7 8 54 1 2 7 7 8 7 36 5 16 50 42 51 1 8 32 3 8 3 3 4 30 5 16 8 3 4 13 3 5 16 9 7 16 30 11 1 8 42 HEARTH 1 1 4 23 Ref 41 3 8 26 3 8 21 3 4 ...

Страница 6: ... PRODUCT SPECIFICATIONS Continued 50 MODEL Figure 3 50 Model VRT6050 Picture may vary from actual firebox 365 16 50 8 3 4 13 35 16 97 16 59 1 8 50 7 7 8 7 30 54 1 2 11 1 8 32 3 8 3 3 4 38 5 16 4 7 8 50 HEARTH 1 1 4 23 Ref 49 3 8 34 3 8 21 3 4 ...

Страница 7: ...utdoors and vents to the outdoors Example Gas water heater 40 000 Btu Hr Vent free fireplace 39 000 Btu Hr Total 79 000 Btu Hr WARNING This heater shall not be installed in a room or space unless the required volume of indoor combustion air is provided by the method described in the National Fuel Gas Code ANSI Z223 1 NFPA 54 the International Fuel Gas Code or applicable local codes Readthefollowin...

Страница 8: ...FuelGasCode orapplicablelocalcodes Figure 4 Ventilation Air from Inside Building Or Remove Door into Adjoining Room Option 3 Ventilation Grills Into Adjoining Room Option 2 Ventilation Grills Into Adjoining Room Option 1 12 12 VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space When ventilating to an adjoining unconfined space you must ...

Страница 9: ...ES WARNING Maintain the minimum clearances If you can provide greater clearances from floor ceil ing and adjoining wall INSTALLATION Carefully follow the instructions below This will ensure safe instal lation Minimum Wall and Ceiling Clearances see Figure 6 A Clearances from the side of the fireplace cabinet to any combus tible material and wall should follow diagram in Figure 6 Example The face o...

Страница 10: ...ust follow the clearances shown in Figure 7 Follow these instructions to install the firebox in this manner 1 Frame in rough opening The firebox framing should be constructed of 2 x 4 lumber or heavier Use dimensions and rough opening lay out in Figure 8 Adjust framing so that firebox flushes with finished wall surface If installing in a corner use dimensions in Figure 9 for rough opening 2 Instal...

Страница 11: ...binet mantel against a wall in your home The firebox and cabinet mantel can be installed directly on the floor Mantels may be available from your retailer or custom built for your home 1 Assemble cabinet mantel as instructed 2 Install gas piping to firebox location See Gas Line Installation on page 14 You may have to cut an access hole in the floor or wall to run gas line to firebox Make sure to l...

Страница 12: ...th and Leading Brick panels Hearth Panel Side leading brick Panel 3 Install the left and right firebrick walls There is a bracket with 2 tabs on the bottom of each firebrick wall Angle the wall into the fireplace opening and into the slots on the side of the hearth Fig ure 14 then tilt the top of the panel toward the firebox surround Figure 14 Slots for Firebrick Walls Figure 15 Installing Side an...

Страница 13: ...e smaller opening is downward and over a moist towel to avoid spilling Place a wet towel over the bucket making sure it is directly on the surface of grout mixture This will keep the mixture moist and it will not dry out before use 5 Grout all joints where two firebrick walls come together 6 Using a trowel remove excess grout mixture by moving trowel in the direction of the joint Grout mixture in ...

Страница 14: ... Fitting Connection Figure 19 Gas Line Installation Side Firebrick Finished Side Brick with Access Hole Outside of Fireplace Gas Line Conduit Insulation Gas Conduit Cover 1 2 Dowel Remove Knockout GAS LINE INSTALLATION CAUTION All gas piping and connections must be tested for leaks after the installation is completed After ensuring that the gas valve is on apply soap and water solution to all conn...

Страница 15: ...6 to 18 for a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the fireplace 2 The serial number of the fireplace 3 The part number 4 The descriptio...

Страница 16: ...SuperiorFireplaces us com 901009 00_NC 16 PARTS VRT6036 VRT6042 AND VRT6050 MODELS 11 10 11 13 14 15 16 14 3 20 20 21 1 19 5 14 15 16 13 12 11 9 7 6 8 17 2 12 18 4 ...

Страница 17: ...replace Top 42 1 Fireplace Top 50 1 9 J6997 Standoff 4 10 Fireplace Surround Assembly 1 11 J4362 Clearance Spacer 6 12 J5329 Fireplace Handle Bracket 4 13 J6900 Outside Air Cover Plate 2 14 J6934 Gas Conduit Cover 4 15 J4368 Conduit One 2 16 J4369 Conduit Two 2 17 Heat Shield Support 1 18 Firebox Top 1 19 J4342 Screen 36 2 J4341 Screen 42 2 J4340 Screen 50 2 20 J6928 Screen Rod 36 2 J4391 Screen R...

Страница 18: ...it F0350 Mosaic50M2 Red Full Stacked F0351 Mosaic50M4 Red Split Stacked F0352 Mosaic50M2 Ivory Full Stacked F0353 Mosaic50M4 Ivory Split Stacked F0354 Mosaic50M3 Red Herr Full F0355 Mosaic50M5 Red Herr Split F0356 Mosaic50M3 Ivory Herr Full F0357 Mosaic50M5 Ivory Herr Split PARTS MOSAIC MASONRY BRICK KITS A Mosaic Masonry brick panel kit is required for use with your VRT6036 VRT6042 or VRT6050 Fir...

Страница 19: ...atural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d damages repairs or inefficiency resulting from faulty installation ...

Страница 20: ...01009 00 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2019 Innovative Hearth Products LLC P N 901009 00 Rev NC 07 2019 1769 East Lawrence Street Russellville AL 35654 ...

Отзывы: