background image

NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.

5

NOTE: The following requirements reference 

various Massachusetts and national codes 

not contained in this document.

Requirements for the Commonwealth 

of Massachusetts

These appliances are approved for installation 
in the US state of Massachusetts if the following 
additional requirements are met:

•    Un-vented Room Heaters shall be installed 

in accordance with 527 CMR 30.

•     Installation and repair must be done by a 

plumber or gas fitter licensed in the Com-

monwealth of Massachusetts.

•     The flexible gas line connector used shall 

not exceed 36 inches (92 centimeters) in 

length.

•     The individual manual shut-off must be a 

T-handle type valve.

•     Unvented appliances may NOT be installed 

in bedrooms or bathrooms.

•      A working smoke detector must be installed 

in the area where vent-free appliances are 

installed.

Seller of unvented propane or natural gas-fired 

supplemental room heaters shall provide to 

each purchaser a copy of 527 CMR 30 upon 

sale of the unit.

Not to Scale

Figure 1

       

CAUTION

Do not install in the vicinity where 

gasoline or other flammable liq-

uids may be stored. The Vent-Free 

firebox must be kept clear and free 

from these combustible materials.

       

WARNING

Do not use a blower insert, heat 

exchanger insert or other acces-

sory not approved for use with this 

appliance.

       

WARNING

Do not install these built-in Vent-

Free fireboxes in sleeping quarters, 

or in recreational vehicles.

       

WARNINGS

Do not install these appliances:

• 

 

Where curtains, furniture, cloth-

ing or other flammable objects 

are less than 42" from the front 

of the Vent-Free room heater.

• 

 

In high traffic areas.

• 

 

In windy or drafty areas.

LOCATION OF FIREBOX

Carefully select the best location for installation 

of your built-in Vent-Free firebox. The following 

factors should be taken into consideration:

  Clearance to side wall, ceiling, woodwork 

and windows.

  Location must not be affected by drafts 

caused by kitchen exhaust fans, return air 

registers for forced air furnaces/air condi-

tioners, windows or doors.

  Installation must provide adequate ventila-

tion and combustion air.

  Do not install this firebox in a sleeping room 

or bathroom.

  Location should be out of high traffic areas 

and away from furniture and draperies due 

to heat from firebox.

•  Never obstruct the front opening of the Vent-

Free firebox or restrict the flow of combustion 

and ventilation air.

•  Minimize modifications to existing construc-

tion.  See Figure 1  for location suggestions.

Содержание VRT3536WH

Страница 1: ...IONS REQUIREDFORTHEINSTALLATIONS THIS IS A VENT FREE GAS FIRED HEATER ENCLO SURE IT USES AIR OXYGEN FROM THE ROOM IN WHICH IT IS INSTALLED PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION AIR MUST B...

Страница 2: ...perating the heater Installation and repair should be done by a qualified service person The heater should be inspected before use and at least annually by a professional service person More frequent...

Страница 3: ...BEGIN NING YOUR INSTALLATION Packaging List Vent Free Gas Firebox Installation and Operation Instructions GENERAL INFORMATION TheseVent Freefireboxenclosuresaredesigned toacceptallANSIZ21 11 2approve...

Страница 4: ...the maximum BTU Hr the space can support with the actual amount of BTU Hr used __________ BTU Hr max the space can support __________ BTU Hr actual amount of BTU Hr used Example 61 440 BTU Hr max the...

Страница 5: ...Vent Free firebox must be kept clear and free from these combustible materials WARNING Do not use a blower insert heat exchanger insert or other acces sory not approved for use with this appliance WA...

Страница 6: ...side of the mantel Clearances Ensure the minimum clearances shown in Figures 2 through 6 are maintained Left and right clearances are determined when facing the front of the firebox Follow these instr...

Страница 7: ...area above Models VRT3536 VRT3542 Series WITH Hood Installed Hood is optional on these models 16 9 1 2 2 3 4 5 6 10 11 12 13 14 15 Top of Firebox Opening Screen Top of Appliance Combustible Mantel and...

Страница 8: ...is unique however and might require a different sequence Step 1 Position firebox prior to framing or into prepared framing Step 2 Field wire the main power supply to the appliance if a blower kit is t...

Страница 9: ...ramed depth from a framed wall must always be measured from a finished surface If a wall covering such as drywall is to be attached to the rear wall then the depth must be measured from the drywall su...

Страница 10: ...200 lbs 22 Cu Ft F0300 VRT3542WS 230 lbs 26 Cu Ft F0301 VRT3542WH 230 lbs 26 Cu Ft Dimensions Inches millimeters Model No A B C D E F G H J K L M N P Q VRT3536WS VRT3536WH 36 914 28 711 41 3 4 1061 41...

Страница 11: ...vel and secure Step 3 Reinstall screen and rod assemblies see Figure 11 Framing Dimensions Opening VRT3536 Series VRT3542 Series A 42 1 4 1073 48 1 4 1226 B 44 1 4 1124 44 1 4 1124 C 23 5 8 600 29 5 8...

Страница 12: ...ired Blower Tab Intact Plug blower into this receptacle Ground Green Wall mounted ON OFF Blower Switch or Variable Speed Control Switch Ground HOT SIDE OF RECEPTACLE An ON OFF Wall Switch is used with...

Страница 13: ...rdtotakeupslack seeFigure20 Step 4 Locate the tabs shown in Figure 21 Position the blower assembly so that the tabs located on the cabinet base are seated in the notches of the blower bracket Bend the...

Страница 14: ...22 VRT3542WS Shown Loose knot in power cord to take up slack Firebox floor Model VRT3542WS Shown Model VRT3542WS Locating Tabs Bend Locating Tabs Over into notches Use screw provided and secure in pla...

Страница 15: ...Raised Hearth Extension Non Combustible Wall see Figures 4 and 5 Page 7 Fireplace Opening From Base to Bottom of Firebox Opening floor 5 3 4 Max Base APPROVED ACCESSORIES AND COMPONENTS Decorative Vol...

Страница 16: ...wall mounted switch Touch Up Paint Kit Repair of minor scratches and discoloration of the appliance black painted surfaces may be accomplished with the touch up paint kit PA I N T The variable speed...

Страница 17: ...y An exploded view of the firebox with numbered parts and a replacement parts list can be found on the page Normally all parts should be ordered through your distributor or dealer Parts will be shippe...

Страница 18: ..._______________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ___________________...

Страница 19: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard...

Страница 20: ...make changes at any time without notice in design materials specifications prices and the discontinuance of colors styles and products Consult your local distributor for fireplace code information NO...

Отзывы: