VRT3042 AND VCT3042

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Mantel Clearance

Minimum Wall and Ceiling Clearances

A.  Clearances from the side of the fireplace cabinet to any combustible 

material and wall should follow diagram shown here.

 

Example: The face of a mantel, bookshelf, etc. is made of combustible 

material and protrudes 3-1/2” from the wall. This combustible material 

must be 4” from the side of the fireplace cabinet.

B.  Clearances from the top of the firebox opening to the ceiling should not 

be less than 42”.

C.  When the firebox is installed directly on carpeting, vinyl tile or other 

combustible material, other than wood flooring, the firebox should be 

installed on a metal or wood panel extending the full width and depth of 

the enclosure.

D.  Clearances from the bottom of firebox to the floor is 0”.

INTERNAL WALL

INSTALLATION

CORNER

INSTALLATION

FULL

PROJECTION

INSTALLATION

FLUSH

INSTALLATION

Typic

al L

oc

ations

Nailing F

langes

Pr

oduc

t Inf

or

ma

tion

Listing Inf

or

ma

tion

PFS

®

US

C

Report No. F12-020

Cat. #

Model

Type

Interior

Weight

Cu. Ft.

F0306

VRT3042B

Radiant

Black

224 lb.

32

F0307

VCT3042B

Louver

Black

224 lb.

32

F0316 VRT3042WS Radiant

WS refractory

224 lb.

32

F0317 VCT3042WS Louver

WS refractory

224 lb.

32

F0318 VRT3042RS Radiant

RS refractory

224 lb.

32

F0319 VCT3042RS

Louver

RS refractory

224 lb.

32

F0320 VRT3042RH Radiant

RH refractory

224 lb.

32

F0321 VCT3042RH

Louver

RH refractory

224 lb.

32

12-1/4 (312)

10-1/2 (267)

8-3/4 (223)

7 (178)

5-1/4 (134)

3-1/2 (89)

1-3/4 (45)

7/8 (23)

1/2 (13)

1/2

(13)

1

(26)

2

(51)

4

(102)

6

(153)

8

(204)

10

(254)

12

(305)

14

(356)

16

(407)

Example

Inch (millimeter)

These appliances comply with National 
Safety Standards and are listed by PFS Cor-
poration to ANSI Z21.91 Ventless Firebox 
Enclosures for Gas-Fired Unvented Decora-
tive Room Heaters and is approved for use 
with appliances listed to ANSI Z21.11.2 
decorative type unvented room heaters.

Supplied

Firebox Hood

Must Be Used

at All Times

Wire-mesh

Screen

Firebox

Noncombustible

Material May

Project Off this

Surface above

the Firebox Hood

Mantel Shelf

Note: Any portion of the

mantel shelf must NOT

extend beyond this profile.

1-1/2 (38)

6-3/4 (172) 

12 (305)

Note: All vertical

measurements are

from top of fireplace

hood opening to

bottom of mantel shelf.

These minimum

clearances replace any

other recommended

clearances supplied

with your ANSI Z21.11.2

approved gas logs.

Wall board or facing

material (above

firebox) may be of

combustible material,

including decorative

mantel ornaments or

other similar projec-

tions off of the facing

material.

Framing

Material

20

(508)

16

(407)

12

(305)

Inch (millimeter)

Nails or Wood 

Screws

Nailing Flange

Mantel from Top of Opening

Mantel Depth Allowed

12” (305 mm)

1-1/2” (38 mm) max.

16” (407 mm)

6-3/4” (172 mm) max.

20” (508 mm)

12” (305 mm) max.