Printed in U.S.A. © 2016 Innovative Hearth Products
P/N 900660-02 REV. NC 04/2016
Page 2 of 2
Specifications and clearances are subject to change without notice.
Refer to Installation and Operation Manual before installation of these
appliances for updated dimensions and instructions.
Clear
anc
es
VRT3042 AND VCT3042
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Mantel Clearance
Minimum Wall and Ceiling Clearances
A. Clearances from the side of the fireplace cabinet to any combustible
material and wall should follow diagram shown here.
Example: The face of a mantel, bookshelf, etc. is made of combustible
material and protrudes 3-1/2” from the wall. This combustible material
must be 4” from the side of the fireplace cabinet.
B. Clearances from the top of the firebox opening to the ceiling should not
be less than 42”.
C. When the firebox is installed directly on carpeting, vinyl tile or other
combustible material, other than wood flooring, the firebox should be
installed on a metal or wood panel extending the full width and depth of
the enclosure.
D. Clearances from the bottom of firebox to the floor is 0”.
INTERNAL WALL
INSTALLATION
CORNER
INSTALLATION
FULL
PROJECTION
INSTALLATION
FLUSH
INSTALLATION
Typic
al L
oc
ations
Nailing F
langes
Pr
oduc
t Inf
or
ma
tion
Listing Inf
or
ma
tion
PFS
®
US
C
Report No. F12-020
Cat. #
Model
Type
Interior
Weight
Cu. Ft.
F0306
VRT3042B
Radiant
Black
224 lb.
32
F0307
VCT3042B
Louver
Black
224 lb.
32
F0316 VRT3042WS Radiant
WS refractory
224 lb.
32
F0317 VCT3042WS Louver
WS refractory
224 lb.
32
F0318 VRT3042RS Radiant
RS refractory
224 lb.
32
F0319 VCT3042RS
Louver
RS refractory
224 lb.
32
F0320 VRT3042RH Radiant
RH refractory
224 lb.
32
F0321 VCT3042RH
Louver
RH refractory
224 lb.
32
12-1/4 (312)
10-1/2 (267)
8-3/4 (223)
7 (178)
5-1/4 (134)
3-1/2 (89)
1-3/4 (45)
7/8 (23)
1/2 (13)
1/2
(13)
1
(26)
2
(51)
4
(102)
6
(153)
8
(204)
10
(254)
12
(305)
14
(356)
16
(407)
Example
Inch (millimeter)
These appliances comply with National
Safety Standards and are listed by PFS Cor-
poration to ANSI Z21.91 Ventless Firebox
Enclosures for Gas-Fired Unvented Decora-
tive Room Heaters and is approved for use
with appliances listed to ANSI Z21.11.2
decorative type unvented room heaters.
Supplied
Firebox Hood
Must Be Used
at All Times
Wire-mesh
Screen
Firebox
Noncombustible
Material May
Project Off this
Surface above
the Firebox Hood
Mantel Shelf
Note: Any portion of the
mantel shelf must NOT
extend beyond this profile.
1-1/2 (38)
6-3/4 (172)
12 (305)
Note: All vertical
measurements are
from top of fireplace
hood opening to
bottom of mantel shelf.
These minimum
clearances replace any
other recommended
clearances supplied
with your ANSI Z21.11.2
approved gas logs.
Wall board or facing
material (above
firebox) may be of
combustible material,
including decorative
mantel ornaments or
other similar projec-
tions off of the facing
material.
Framing
Material
20
(508)
16
(407)
12
(305)
Inch (millimeter)
Nails or Wood
Screws
Nailing Flange
Mantel from Top of Opening
Mantel Depth Allowed
12” (305 mm)
1-1/2” (38 mm) max.
16” (407 mm)
6-3/4” (172 mm) max.
20” (508 mm)
12” (305 mm) max.