background image

Printed in U.S.A. © 2016 Innovative Hearth Products

P/N  900660-01  REV. 

A  02/2017

 

Page 2 of 2

Specifications and clearances are subject to change without notice.  

Refer to Installation and Operation Manual before installation of these 

appliances for updated dimensions and instructions.

Clear

anc

es

VRT3036 AND VCT3036

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Mantel Clearance

Minimum Wall and Ceiling Clearances

A.  Clearances from the side of the fireplace cabinet to any combustible 

material and wall should follow diagram shown here.

 

Example: The face of a mantel, bookshelf, etc. is made of combustible 

material and protrudes 3-1/2” from the wall. This combustible material 

must be 4” from the side of the fireplace cabinet.

B.  Clearances from the top of the firebox opening to the ceiling should not 

be less than 42”.

C.  When the firebox is installed directly on carpeting, vinyl tile or other 

combustible material, other than wood flooring, the firebox should be 

installed on a metal or wood panel extending the full width and depth of 

the enclosure.

D.  Clearances from the bottom of firebox to the floor is 0”.

INTERNAL WALL

INSTALLATION

CORNER

INSTALLATION

FULL

PROJECTION

INSTALLATION

FLUSH

INSTALLATION

Typic

al L

oc

ations

Nailing F

langes

Pr

oduc

t Inf

or

ma

tion

Listing Inf

or

ma

tion

PFS

®

US

C

Report No. F12-020

Cat. #

Model

Type

Interior

Weight

Cu. Ft.

F0304

VRT3036B

Radiant

Black Interior

184 lb.

32.4

F0305

VCT3036B

Louvered

Black Interior

184 lb.

32.4

F0310 VRT3036WS

Radiant

WS refractory 184 lb.

32.4

F0311 VCT3036WS

Louvered

WS refractory 184 lb.

32.4

F0312 VRT3036RS

Radiant

RS refractory

184 lb.

32.4

F0313

VCT3036RS

Louvered

RS refractory

184 lb.

32.4

F0314 VRT3036RH

Radiant

RH refractory

184 lb.

32.4

F0315 VCT3036RH

Louvered

RH refractory

184 lb.

32.4

12-1/4 (312)

10-1/2 (267)

8-3/4 (223)

7 (178)

5-1/4 (134)

3-1/2 (89)

1-3/4 (45)

7/8 (23)

1/2 (13)

1/2

(13)

1

(26)

2

(51)

4

(102)

6

(153)

8

(204)

10

(254)

12

(305)

14

(356)

16

(407)

Example

Inch (millimeter)

These appliances comply with National 
Safety Standards and are listed by PFS Cor-
poration to ANSI Z21.91 Ventless Firebox 
Enclosures for Gas-Fired Unvented Decora-
tive Room Heaters and is approved for use 
with appliances listed to ANSI Z21.11.2 
decorative type unvented room heaters.

Supplied

Firebox Hood

Must Be Used

at All Times

Wire-mesh

Screen

Firebox

Noncombustible

Material May

Project Off this

Surface above

the Firebox Hood

Mantel Shelf

Note: Any portion of the

mantel shelf must NOT

extend beyond this profile.

1-1/2 (38)

6-3/4 (172) 

12 (305)

Note: All vertical

measurements are

from top of fireplace

hood opening to

bottom of mantel shelf.

These minimum

clearances replace any

other recommended

clearances supplied

with your ANSI Z21.11.2

approved gas logs.

Wall board or facing

material (above

firebox) may be of

combustible material,

including decorative

mantel ornaments or

other similar projec-

tions off of the facing

material.

Framing

Material

20

(508)

16

(407)

12

(305)

Inch (millimeter)

Nails or Wood 

Screws

Nailing Flange

Mantel from Top of Opening

Mantel Depth Allowed

12” (305 mm)

1-1/2” (38 mm) max.

16” (407 mm)

6-3/4” (172 mm) max.

20” (508 mm)

12” (305 mm) max.

Отзывы: