background image

SuperiorFireplaces.us.com

127026-01_D

11

INSTALLATION  

continued

Figure 10 - Attaching Firebox to Wall Studs

Nailing 

Flanges

Nails or 

Wood 

Screws 

IMPORTANT:

 When finishing your firebox, combustible materials such 

as wall board, gypsum board, sheet rock, drywall, plywood, etc. may 

be butted up next to the sides and top of the firebox. Combustible 

materials should never overlap the firebox front facing.

 WARNING: Do not allow any combustible materials 

to overlap the firebox front facing.

IMPORTANT:

 Noncombustible materials such as brick, tile, etc. 

may overlap the front facing, but should never cover any necessary 

openings.

 WARNING: Do not allow noncombustible materials 

to cover any necessary openings.

 WARNING: Use only noncombustible mortar or 

adhesives when overlapping the front facing with 

noncombustible facing material.

INSTALLING FIREBOX USING OPTIONAL CUSTOM 

BUILT MANTELS

 WARNING: A qualified service person must install 

firebox. Follow all local codes.

This firebox may be installed using a cabinet mantel against a wall in 

your home. The firebox and cabinet mantel can be installed directly 

on the floor. Mantels may be available from your retailer or custom 

built for your home.

1.  Assemble cabinet mantel as instructed.

2.  Install gas piping to firebox location. See Gas Line Installation on 

page 13. You may have to cut an access hole in the floor or wall to 

run gas line to firebox. Make sure to locate access hole so cabinet 

mantel will cover it when installed (see Figure 11).

3.  Place firebox on floor in desired location. Make sure mantel will 

be flush against wall when installed.

4.  Carefully slide cabinet mantel over firebox. Be careful not to 

scratch firebox, cabinet mantel, flooring, etc., when installing 

(see Figure 12).

5.  Install and properly test gas log heater. Follow installation in-

structions included with the vent-free gas log heater that is being 

installed.

Figure 12 - Inserting Firebox Into Cabinet Mantel (Mantel May Vary 

From Illustration)

Figure 11 - Installing Cabinet Mantel (Mantel May Vary From 

Illustration)

Cabinet 

Mantel

Gas 

Piping 

Gas Line Access 

Hole (Either Side 

of Firebox)

Содержание VRE6036IH

Страница 1: ...pplier SAVE THIS BOOK This book is valuable In addition to instructing you on how to install and maintain your appliance it also contains information that will enable you to obtain replacement parts o...

Страница 2: ...e provided with the unvented decorative room heater IMPORTANT Read this owner s manual carefully and completely before trying to assemble operate or service this fireplace Improper use of this firepla...

Страница 3: ...trically grounded in accordance with the National Electrical Code ANSI NFPA70 latest edition Available from American National Standards Institute Inc 25 West 43rd Street 4th floor New York NY 10036 Na...

Страница 4: ...D 4 PRODUCT SPECIFICATIONS 36 MODELS Figure 1 36 Models VRE6036RS VRE6036IS VRE6036RH and VRE6036IH 20 1 4 Ref 1 1 4 22 1 2 19 36 HEARTH 29 30 1 2 30 36 54 1 2 11 1 8 45 1 8 36 3 8 35 1 4 9 1 2 3 3 8...

Страница 5: ...RODUCT SPECIFICATIONS continued 42 MODELS Figure 2 42 Models VRE6042RS VRE6042IS VRE6042RH and VRE6042IH 42 HEARTH 21 3 4 8 3 4 3 3 8 9 1 2 26 3 8 41 3 8 4 7 8 1 1 4 3 3 4 32 3 8 36 3 8 11 1 8 7 7 8 5...

Страница 6: ...6 Figure 3 50 Models VRE6050RS VRE6050IS VRE6050RH and VRE6050IH 21 3 4 8 3 4 9 1 2 3 3 8 13 50 50 7 30 34 3 8 38 3 8 4 7 8 49 3 8 36 3 8 59 1 8 54 1 2 11 1 8 3 3 4 32 3 8 7 7 8 23 Ref 50 HEARTH PRODU...

Страница 7: ...ve you must provide ad ditional fresh air See Ventilation Air From Outdoors page 8 If your home does not meet all of the three criteria above proceed to Determining Fresh Air Flow For Firebox Location...

Страница 8: ...ined space When ventilating to an adjoining unconfined space you must provide two permanent openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces s...

Страница 9: ...tom of your firebox except where standoff spacers are integrally attached If standoff spacers are attached to your firebox these spacers can be placed directly against wall or framing materials Use th...

Страница 10: ...al product standard Fol low all minimum clearances shown in this manual NOTICE Ifyourinstallationdoesnotmeettheminimum clearances shown you must do one of the following raise the mantel to an acceptab...

Страница 11: ...es This firebox may be installed using a cabinet mantel against a wall in your home The firebox and cabinet mantel can be installed directly on the floor Mantels may be available from your retailer or...

Страница 12: ...ight Face Slot Figure 14 Slots for Firebrick Walls Figure 15 Installing Side Walls Retaining Bracket Figure 13 Removing Shipping Brackets GROUTING INSTRUCTIONS Material provided Bag of cement Bag of s...

Страница 13: ...eplace chamber for fitting connection see Figure 19 Note Secureincominggaslinetowoodframingtoproviderigidityfor threaded end 4 Repack insulation around gas line and into sleeve opening Seal any gaps b...

Страница 14: ...0 21 20 1 19 5 14 15 16 13 12 11 9 7 6 8 17 2 12 18 4 PARTS MODEL NO CATALOG NO VRE6036RS F0461 VRE6036IS F0462 VRE6036RH F0463 VRE6036IH F0464 VRE6042RS F0465 VRE6042IS F0466 VRE6042RH F0467 VRE6042I...

Страница 15: ...ULATION 1 8 RP110454 03 TOP FIREPLACE 36 1 RP110454 02 TOP FIREPLACE 42 1 RP110454 01 TOP FIREPLACE 50 1 9 J6997 SPACER FIREPLACE TOP 42MC 4 10 FIREPLACE SURROUND ASSEMBLY 1 11 J4362 SPACER CLEARANCE...

Страница 16: ...performance and safety hazards MODEL NO CATALOG NO VRE6036RS F0461 VRE6036IS F0462 VRE6036RH F0463 VRE6036IH F0464 VRE6042RS F0465 VRE6042IS F0466 VRE6042RH F0467 VRE6042IH F0468 VRE6050RS F0469 VRE6...

Страница 17: ...J6464 ASSY LT PANEL CUT FSB42R 1 J6470 ASSY LT PANEL CUT FHB42R 1 J6478 ASSY LT PANEL CUT FRB50R 1 J6486 ASSY LT PANEL CUT FHB50R 1 7 J7682 BRACKET RETAINER REF VF 3 8 J5563 ASSY BRICK ASH BOX RED 1...

Страница 18: ...ve the following information 1 The model number of the fireplace 2 The serial number of the fireplace 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of...

Страница 19: ...ned to burn either natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could resul...

Страница 20: ...ealer name P127026 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and produ...

Отзывы: