background image

Printed in U.S.A. © 2016 Innovative Hearth Products

P/N  900667-02  REV. NC  05/2016

Page 2 of 2

Specifi cations and clearances are subject to change without notice.  
Refer to Installation Manual before installation of these appliances for 
updated dimensions and instructions.

Clear

anc

es

VRE4032 SERIES

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Supplied
Firebox Hood
Must Be Used
at All Times

Wire-mesh
Screen

Firebox

Noncombustible
Material May
Project Off this
Surface above
the Firebox Hood

Mantel Shelf
Note: Any portion of the
mantel shelf must NOT
extend beyond this profile.

1-1/2 (38)

6-3/4 (172) 

12 (305)

Note: All vertical
measurements are
from top of fireplace
hood opening to
bottom of mantel shelf.
These minimum
clearances replace any
other recommended
clearances supplied
with your ANSI Z21.11.2
approved gas logs.

Wall board or facing
material (above
firebox) may be of
combustible material,
including decorative
mantel ornaments or
other similar projec-
tions off of the facing
material.

Framing
Material

20

(508)

16

(407)

12

(305)

Inch (millimeter)

Minimum Wall and Ceiling Clearances (see fi gure below)

A.  Clearances from the side of the fi replace cabinet to any combustible 

material and wall should follow diagram shown here.

 

Example: The face of a mantel, bookshelf, etc. is made of combustible 
material and protrudes 3-1/2” from the wall. This combustible mate-
rial must be 4” from the side of the fi replace cabinet.

B.  Clearances from the top of the fi rebox opening to the ceiling should 

not be less than 42”.

C.  When the fi rebox is installed directly on carpeting, vinyl tile or other 

combustible material, other than wood fl ooring, the fi rebox should be 
installed on a metal or wood panel extending the full width and depth 
of the enclosure.

D.  Clearances from the bottom of fi rebox to the fl oor is 0”.

12-1/4 (312)

10-1/2 (267)

8-3/4 (223)

7 (178)

5-1/4 (134)

3-1/2 (89)

1-3/4 (45)

7/8 (23)

1/2 (13)

1/2

(13)

1

(26)

2

(51)

4

(102)

6

(153)

8

(204)

10

(254)

12

(305)

14

(356)

16

(407)

Example

Inch (millimeter)

Pr

oduc

t Inf

ormation

Listing Inf

ormation

PFS

®

US

C

Report No. F09-130

Cat. No.

Model

Refractory

Weight

Cu. Ft.

F0485

VRE4032RS

Red Stacked

138 lb

14

F0491

VRE4032WS

White Stacked

138 lb

14

F0486

VRE4032RH

Red Herringbone

138 lb

14

F0492

VRE4032WH

White Herringbone

138 lb

14

These appliances comply with National 
Safety Standards and are listed by PFS Cor-
poration to ANSI Z21.91 Ventless Firebox 
Enclosures for Gas-Fired Unvented Decora-
tive Room Heaters and is approved for use 
with appliances listed to ANSI Z21.11.2 
decorative type unvented room heaters.

Nailing F

langes

Nailing 
Flanges

Nails or Wood 
Screws 

Indoor Firebox

Nailing 
Flanges

Nails or 
Wood 
Screws 

Indoor/Outdoor Firebox