Figure 5 - Ventilation Air from Outdoors

Outlet

Air

Ventilated

Attic 

Outlet

Air

Inlet

Air

Inlet Air

Ventilated 

Crawl Space

To 

Crawl

Space

To Attic

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation 

grills or ducts. You must provide two perma

-

nent openings: one within 12" of the ceiling 

and one within 12" of the floor. Connect these 

items directly to the outdoors or spaces open 

to the outdoors. These spaces include attics 

and crawl spaces. Follow the 

National Fuel 

Gas Code, ANSI Z223.1/NFPA 54, Air for 

Combustion and Ventilation

 for required size 

of ventilation grills or ducts.

IMPORTANT:

 Do not provide openings for 

inlet or outlet air into attic if attic has a thermo-

stat-controlled power vent. Heated air entering 

the attic will activate the power vent.

 WARNING: A qualified ser-

vice person must install firebox. 

Follow all local codes.

 WARNING: Never install 

firebox

•  in a bedroom or bathroom*

•  in a recreational vehicle

•  where  curtains,  furniture, 

clothing, or other  flammable 

objects are less than 36" from 

front or 42" from top of firebox; 

for side clearances see Figure 

4, page 11

•  in high traffic areas

•  in windy or drafty areas

* Unless installed log set is rated at 10,000 
Btu/Hr or less, 6,000 for bathrooms

 CAUTION: Log heaters 

installed  in  this  firebox  create 

warm air currents. These currents 

move heat to wall surfaces next 

to firebox. Installing firebox next 

to vinyl or cloth wall coverings or 

operating firebox where impuri-

ties (such as, but not limited to, to-

bacco smoke, aromatic candles, 

cleaning fluids, oil or kerosene 

lamps, etc.) in the air exist, may 

discolor walls or cause odors.

INSTALLATION

NOTICE: The firebox identifica-

tion label (including model num-

ber, serial number, clearances, 

etc.) is located on a chain under 

the bottom refractory.

IMPORTANT:

 Vent-free gas log heaters add 

moisture to the air. Although this is beneficial, 

installing  firebox  in  rooms  without  enough 

ventilation air may cause mildew to form from 

too much moisture. See, page 8.

IMPORTANT:

 Make sure the firebox is level. 

If  firebox  is  not  level,  log  set  will  not  work 

properly.

Note: Your firebox is designed to be used in 

zero clearance installations. Wall or framing 

material can be placed against any exterior 

surface on the rear, sides, top or bottom of 

your firebox, except where standoff spacers 

are integrally attached. If standoff spacers are 

attached to your firebox, these spacers can 

be placed directly against wall or framing ma-

terials. Use the dimensions shown for rough 

opening to create the easiest installation.

Use  dimensions  shown  for  rough  openings 

to create the easiest installation (see 

Built-In 

Firebox Installation

, page 12).

AIR FOR COMBUSTION AND VENTILATION

Continued

Содержание P127026-01

Страница 1: ...e is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used WARNING If the information in these instr...

Страница 2: ...ESS THIS FIREBOX MEETS THE MINIMUM DIMEN SIONS REQUIRED FOR THE INSTALLATION WARNING FOR USE ONLY WITH A LISTED GAS FIRED UNVENTED DECORATIVE ROOM HEATER NOT TO EXCEED 40 000 BTU H DO NOT BUILD A WOOD...

Страница 3: ...re running installed gas log heater Replace hood with In novativeHearthProductsmodel 109511 0150 109511 0242 or 109511 03 36 only This hood has been designed to keep the operation of your fireplace sa...

Страница 4: ...inexpensive LOCAL CODES LOCATING FIREBOX PLANNING Plan where you will install the firebox This will save time and money later when you install the firebox Before installation consider the following 1...

Страница 5: ...01A 5 PRODUCT SPECIFICATIONS 36 MODELS Figure 1 36 Models VRE6036RS VRE6036IS VRE6036RH and VRE6036IH 30 1 2 29 30 11 1 8 54 1 2 7 7 8 7 36 45 1 8 35 16 97 16 50 365 16 7 3 8 111 8 3 3 4 4 7 8 36 HEAR...

Страница 6: ...RODUCT SPECIFICATIONS Continued 42 MODELS Figure 2 42 Models VRE6042RS VRE6042IS VRE6042RH and VRE6042IH 4 7 8 54 1 2 7 7 8 7 36 5 16 50 42 51 1 8 32 3 8 3 3 4 30 5 16 8 3 4 13 3 5 16 9 7 16 30 11 1 8...

Страница 7: ...PRODUCT SPECIFICATIONS Continued 50 MODELS Figure 3 50 Models VRE6050RS VRE6050IS VRE6050RH and VRE6050IH 365 16 50 8 3 4 13 35 16 97 16 59 1 8 50 7 7 8 7 30 54 1 2 11 1 8 32 3 8 3 3 4 38 5 16 4 7 8 5...

Страница 8: ...sheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between...

Страница 9: ...pace because the actual Btu Hr used is more than the maximum Btu Hr the space can support You must provide additional fresh air Your options are as follows A Rework worksheet adding the space of an ad...

Страница 10: ...bathrooms CAUTION Log heaters installed in this firebox create warmaircurrents Thesecurrents move heat to wall surfaces next to firebox Installing firebox next tovinylorclothwallcoveringsor operating...

Страница 11: ...m mantel above built in fire box you must meet the minimum allowable clearance between mantel shelf and top of firebox opening shown in Figure 7 These are the minimum allowable mantel clearances for a...

Страница 12: ...refully insert firebox into rough opening 5 Attach firebox to wall studs using nails or wood screws through holes in nailing flange see Figure 10 6 Install and properly test gas log heater Follow inst...

Страница 13: ...he firebox and cabinet mantel can be installed directly on the floor Mantels may be avail able from your retailer or custom built for your home 1 Assemble cabinet mantel as instructed 2 Install gas pi...

Страница 14: ...nel toward the firebox surround Hearth Right Face Slot Figure 14 Slots for Firebrick Walls 3 Secure the firebrick wall using 2 of the retainers provided The bracket will slip underneath the metal lip...

Страница 15: ...to avoid spilling Place a wet towel over the bucket making sure it is directly on the surface of grout mixture This will keep the mixture moist and it will not dry out before use 5 Grout all joints wh...

Страница 16: ...nce or cap off gas line if desired A gas line or gas log lighter may be installed for the purpose of installing a vent free decora tive gas appliance incorporating an automatic shutoff device and comp...

Страница 17: ...has a broken component please do not return it to the store Call INNOVATIVE HEARTH PRODUCTS at 1 800 655 2008 to answer questions and replace parts under warranty Note Use only original replacement p...

Страница 18: ...www SuperiorFireplaces US com 127016 01A 18 PARTS 36 42 AND 50 SUPERIOR MODELS 11 10 11 13 14 15 16 14 3 22 20 21 20 1 19 5 14 15 16 13 12 11 9 7 6 8 17 2 12 18 4...

Страница 19: ...14 21171 Gas Conduit Cover 4 15 109752 01 Conduit One 2 16 109752 02 Conduit Two 2 17 Heat Shield Support 1 18 123298 02 Ash Box Assembly 1 19 Firebox Top 1 20 109457 03 Screen 36 2 109457 02 Screen...

Страница 20: ...www SuperiorFireplaces US com 127016 01A 20 PARTS 36 42 AND 50 SUPERIOR MODELS Picture may vary from actual 1 6 4 3 2 5 7 7 7 8 Note See pages 21 thru 24 for part numbers...

Страница 21: ...d 36 Red 1 124222 01 Rear Herringbone 36 Red 1 125413 01 Rear Stacked 42 Red 1 125425 01 Rear Herringbone 42 Red 1 125437 01 Rear Stacked 50 Red 1 125449 01 Rear Herringbone 50 Red 1 5 124212 01 Right...

Страница 22: ...Red 1 4 124216 01 Rear Stacked 36 Red 1 124228 01 Rear Herringbone 36 Red 1 125419 01 Rear Stacked 42 Red 1 125431 01 Rear Herringbone 42 Red 1 125443 01 Rear Stacked 50 Red 1 125455 01 Rear Herringb...

Страница 23: ...clearances be such as to in terfere with combustion air and accessibility d Installations shall be of a permanent type with a permanently piped fuel sup ply in accordance with 248 CMR LPG appliances...

Страница 24: ...ith the unvented decorative room heater WARNING DO NOT INSTALL IN SLEEPING ROOM OF MOBILE HOMES WARNING Discontinue use of the appliance immediately if doors are damaged and contact a quali fied insta...

Страница 25: ...www SuperiorFireplaces US com 127016 01A 25 NOTES...

Страница 26: ...al or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c dam...

Страница 27: ...EP THIS WARRANTY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ___________...

Страница 28: ...127026 01 Rev A 01 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P127026 01...

Отзывы: