background image

SuperiorFireplaces.us.com

900467-01B

15

OPERATION

9.  Slightly push in and turn control knob counterclockwise 

 

to the ON position.

10.Wait one minute and move switch to the ON position to 

light burner.

 

NOTE

: AUTO is only functional when using optional remote 

control accessory.

11. Set flame adjustment knob to any level between HI and LO.

FOR YOUR SAFETY 

READ BEFORE LIGHTING

 

WARNING: If you do not follow these instruc

-

tions exactly, a fire or explosion may result 

causing property damage, personal injury or 

loss of life.

A. This appliance has a pilot which must be lighted with 

a piezo igniter. When lightning the pilot, follow these 

instructions exactly.

B. BEFORE LIGHTING smell all around the appliance area 

for gas. Be sure to smell next to the floor because some 

gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do  not  touch  any  electric  switch;  do  not  use  any 

phone in your building.

• Immediately call your gas supplier from a neighbor’s 

phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire 

department.

C.  Use only your hand to push in or turn gas control knob. 

Never use tools. If the knob will not push in or turn by 

hand, do not try to repair it, call a qualified technician. 

Force or attempted repair may result in a fire.

D. Do not use this appliance if any part has been under water. 

Immediately call a qualified service technician to inspect 

the appliance and to replace any part of the control sys-

tem and any gas control which has been under water.

LIGHTING

 

 INSTRUCTIONS

1.  STOP! Read the safety information, above.
2.  Make sure switch is in the OFF position. 
3.  Be sure gas line shut-off valve is OPEN.
4.  Press in and turn control knob clockwise 

 to the 

OFF position 

(see 

Figure 26

)

.

 

NOTE

: Knob cannot be turned from PILOT to OFF unless 

knob is pushed in slightly. DO NOT FORCE.

5.  Wait five (5) minutes to clear out any gas. If you then smell 

gas, STOP! Follow "B" in the safety information in column 

1. If you don't smell gas, go on the next step.

6. Press in and turn control knob counterclockwise 

 

to the PILOT position. Press in control knob for five (5) 

seconds 

(see 

Figure 26

)

.

7. With control knob pressed in, press and release igniter 

button. This will light pilot. If needed, keep pressing igniter 

button until pilot lights.

 

NOTE

: If pilot does not stay lit, contact a qualified service 

person or gas supplier for repairs.

8.  Keep control knob pressed in for 30 seconds after lighting 

pilot. After 30 seconds, release control knob.

• If control knob does not pop out when released, turn off 

gas supply and contact a qualified service person or gas 

supplier for repairs.

 

NOTE

: If pilot goes out, repeat steps 4 through 8.

TO TURN OFF GAS 

TO APPLIANCE

1.  Turn control knob clockwise 

 to the OFF position.

2a.Set switch in the OFF position.

2b.

If Using Optional Hand-Held Remote: 

Set selector switch 

in the OFF position to prevent draining battery. 

3.  Close equipment shutoff valve 

(see 

Figure 13, Page 9

)

.

MANUAL LIGHTING

 

PROCEDURE

1.  Follow steps 1 through 6 under 

Lighting Instructions

.

2.  Press control knob and light pilot with match. 

3.  Keep control knob pressed in for 30 seconds after light-

ing pilot. After 30 seconds, release control knob. Now 

follow steps 9 through 11, under 

Lighting Instructions

.

OPTIONAL HAND-HELD

 

REMOTE OPERATION

NOTE

: All  remote  control  accessories  must  be  purchased 

separately (see Accessories, 

Page 23

). Follow instructions 

included with the remote control.

NOTICE: You must light the pilot before using 

the hand-held remote control unit. See 

Lighting 

Instructions

.

After lighting, let pilot flame burn for about one minute. Turn 

control knob to ON position. Adjust flame adjustment knob 

anywhere between HI and LO. Slide the selector switch to 

the REMOTE position

 (see 

Figure 26

). 

Figure 26 - Control Knob, Igniter Button and Remote 

Selector Switch

Selector 

Switch 

Control 

Knob in OFF 

Position 

Flame Adjustment 

Knob 

Igniter

NOTE

: The burner may light if hand-held remote was on when 

selector switch was last turned off. You can now turn burner 

on and off with hand-held remote control unit.

 

IMPORTANT

Do not leave selector switch in the REMOTE 

or ON position when pilot is not lit. This will drain the battery.

f i r e - p a r t s . c o m

Содержание LMF30GT

Страница 1: ...warnings exactly could result in serious injury death or property damage INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference WHEN USED AS AN OUTDOOR APPLIAN...

Страница 2: ...r maintenance can cause injury or property damage Refer to this manual for correct in stallation and operational procedures For assistance or additional information consult a qualified installer servi...

Страница 3: ...on adjacent walls and furniture 9 Do not use this appliance as a wood burning appliance Use only the logs provided with the appliance Do not burn solid fuels in this appliance 10 Do not run appliance...

Страница 4: ...ELECTRONIC IGNITION SYSTEM This appliance has an electronic igniter to light appliance fuel supply INSTALLATION WARNING Aqualified service person must install appliance Follow all local codes NOTICE...

Страница 5: ...accessory Even if noncombustible material is more than 12 you may need the hood accessory to deflect heat away from your mantel shelf See Figure 3 and Figures 4 and 5 Page 6 for minimum clearances IMP...

Страница 6: ...mum Non Combustible Material Height Distances to Underside of Mantel Top of Fireplace Opening Underside of Mantel Shelf 12 A 18 20 22 24 All minimum distances are in inches 2 1 2 6 8 10 Mantel Shelf M...

Страница 7: ...ensure adequate air flow and guard against sooting and controls being dam aged Raisefireplacefloorwithnoncombustible material Make sure material is secure Installation Items Needed hardware package pr...

Страница 8: ...This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged appliance valves WARNING Use pipe joint sealant that is resistant to liquid petroleum LP gas Figure...

Страница 9: ...gas supply pressure for purpose of input adjustment Figure 12 Gas Connection Pipe Cap Tee Nipple Joint Gas Control 3 Minimum Sediment Trap Equipment Shutoff Valve With 1 8 NPT Tap Approved Flexible G...

Страница 10: ...re removed from appliance for install remote ac cessory replace logs see Installing Logs and Volcanic Stone Page 11 10 Place remote receiver on fireplace floor next to control valve Make sure the remo...

Страница 11: ...lation instructionsinthismanual Flamescontacting logs will create soot LOG PLACEMENT It is very important to install these logs exactly as instructed Do not modify logs Only use logs supplied with app...

Страница 12: ...embly by inserting it from the left side as shown in Figure 19 You will need to twist the log slightly to get it to fit against the burners properly It will rest even with the back edge of the pan Bac...

Страница 13: ...forward The log has a notch that fits around the burner tube on the right side The left side of the burner tube fits into the notch on the back side of this log The log is placed properly when it sits...

Страница 14: ...round hole that fits over the round peg that is on the top of the back left log The right end of this log has a rectangular hole that fits over the rectangular peg on the top of the right crossover l...

Страница 15: ...smell gas go on the next step 6 Press in and turn control knob counterclockwise to the PILOT position Press in control knob for five 5 seconds see Figure 26 7 With control knob pressed in press and r...

Страница 16: ...rnersandcirculatingairpassagewaysofap plianceclean Inspecttheseareasofappliance before each use Have appliance inspected yearly by a qualified service person WARNING Failure to keep the primary air op...

Страница 17: ...ilot shown Thermocouple Thermopile 1 8 Pilot Burner Piezo Igniter 3 8 to 1 2 LOGS If you remove logs for cleaning refer to Installing Logs and Volcanic Stone Page 11 to properly replace logs Replace l...

Страница 18: ...ure in of water Max 14 W C Min 11 W C For purpose of input adjustment MNF30ONM Rating Variable 29 000 40 000 Btu Hr Type Gas Natural Ignition Electronic Manifold Pressure 3 4 W C Inlet Gas Pressure in...

Страница 19: ...lled 5 Depleted gas supply propane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not cor rect REMEDY 1 Reconnect igniter cable 2 Free igniter cable if pinched by any metal or tubing Keep i...

Страница 20: ...eep control knob pressed in 30 seconds 3 Wait one minute for safety in terlock system to reset Repeat ignition operation 4 Fully open equipment shutoff valve 5 A Contact local natural or pro pane LP g...

Страница 21: ...line Have gas line checked by local natural or pro pane LP gas company 3 Observe minimum installation clearances see Pages 4 6 4 Clean burner see Cleaning and Maintenance Page 16 or replace burner or...

Страница 22: ...e LP only 3 Gas leak See Warning state ment at top of page 1 Low line pressure 2 ODS pilot is partially clogged 1 Gas leak See Warning state ment at top of page 2 Control valve or gas control de fecti...

Страница 23: ...ONTROL KIT MRC REMOTE READY MODELS ONLY Cat No F1077 Model MRC For all models Allows the fireplace to be turned on and off by using a hand held remote control WALL MOUNT ON OFF SWITCH REMOTE READY MOD...

Страница 24: ...eplaces us com 900467 01B 24 PARTS REMOTE READY CONTROL MODELS MNF30ONM and MNF30OPM 1 2 5 6 8 9 10 13 14 15 16 17 18 19 20 21 23 24 25 22 11 12 12 7 3 4 Cat No Model F2128 MNF30ONM F2130 MNF30OPM fir...

Страница 25: ...r Electric 1 15 J6144 Bracket Igniter 1 16 J5198 Shutter Air NG 1 J5199 Shutter Air LP 1 17 J3604 Orifice 0 12 NG 1 J3615 Orifice 0 07 LP 1 18 J6127 Orifice Holder 90 Degrees 1 19 J4733 Nut and Sleeve...

Страница 26: ...r assembly The next two numbers indicate the set size 2 6 3 9 1 7 8 5 4 KEY NO CAT NO Log Id CAT NO Log Id DESCRIPTION QTY 1 J6516 D 019 J6527 D 027 Log Front Right 1 2 J6517 D 018 J6528 D 026 Log Bac...

Страница 27: ...d under Re placement Parts on Page 28 of this manual KEY NO CAT NO Log Id CAT NO Log Id DESCRIPTION QTY 1 J8253 D 019 J8259 D 027 Log Front Right 1 2 J8254 D 018 J8260 D 026 Log Back Left 1 3 J8255 D...

Страница 28: ...If you encounter any problems or have any questions con cerning the installation or application of this appliance please contact your dealer SERVICE HINTS When Gas Pressure Is Too Low pilot will not...

Страница 29: ...xcessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d damages re...

Страница 30: ...your local distributor for fireplace code information Printed in U S A 2015 Innovative Hearth Products P N 900467 01 Rev B 01 2019 SuperiorFireplaces us com Record the following important information...

Отзывы: