![background image](http://html1.mh-extra.com/html/superior-fireplaces/drt4036ten/drt4036ten_installation-and-operation-instruction-manual_1403112036.webp)
SuperiorFireplaces.us.com
126721-01G
36
SPECIFICATIONS
DRT4036TEN
• Rating: 33,500 Btu/hr
• Gas Type: Natural Gas Only
• Ignition: Electronic
• Manifold Pressure: 3.5" W.C.
• Minimum Inlet Supply Pressure: 5" W.C.
• Maximum Inlet Supply Pressure: 10.5" W.C.
• Front Orifice: #47
• Rear Orifice: #47
DRT4042TEN
• Rating: 41,000 Btu/hr
• Gas Type: Natural Gas Only
• Ignition: Electronic
• Manifold Pressure: 3.5" W.C.
• Minimum Inlet Supply Pressure: 5" W.C.
• Maximum Inlet Supply Pressure: 10.5" W.C.
• Front Orifice: #42
• Rear Orifice: #44
DRT4036TEP
• Rating: 31,000 Btu/hr
• Gas Type: Propane/LP Gas Only
• Ignition: Electronic
• Manifold Pressure: 10" W.C.
• Minimum Inlet Supply Pressure: 11" W.C.
• Maximum Inlet Supply Pressure: 13" W.C.
• Front Orifice: #56
• Rear Orifice: #56
DRT4042TEP
• Rating: 37,000 Btu/hr
• Gas Type: Propane/LP Gas Only
• Ignition: Electronic
• Manifold Pressure: 10.0" W.C.
• Minimum Inlet Supply Pressure: 11" W.C.
• Maximum Inlet Supply Pressure: 13" W.C.
• Front Orifice: #56
• Rear Orifice: #55
WIRING DIAGRAM
Pilot
Brown
Neg (-)
BATTERY PACK
Red
Black
Pos (+)
To Rocker Switch
To Ground
To J Box
AC
Power
Adaptor
Brown
Main
Valve
Control
Module
SIZE
"AA"
SIZE
"AA"
SIZE
"AA"
SIZE
"AA"