Installation
900948-00E, 07/2020
Innovative Hearth Products
DRT2000-C Series Direct-Vent Gas Fireplaces
32
Firestop/Spacer (SV4.5HF) shown
on the exterior side of the wall. It
may also be installed on the
interior side.
Typical
Termination
Shown
7”
(178)
5-1/8”
(130 mm)
12-1/8”
(308 mm)
Note: Centerline of Vent Piping is
NOT the Same as the Centerline of
the Frame Opening.
6” to 48” Vent Section,
Telescopic vent section,
Elbow or Appliance Collar
Base of Appliance
3”
(77 mm)
1”
(26 mm)
Adaptor
SV4.5RCH
10-1/2”
(267 mm)
*
To help minimize water infiltration
it is recommended that the Fire-
stop/ Spacer (SV4.5HF) be installed
on the exterior side of the wall.
*Recommended IHP termination kit: H1968.
**With termination kit only, 6 to 9-1/4”
**
See
Table 10
for the minimum distance
to the base of the fireplace.
Figure 25 - Installing the Horizontal Termination
NOTE:
To help minimize water infiltration install the firestop/spacer (SV4.5HF) on the exterior side of the wall. The
firestop may be caulked with mill base caulk (such as 10K81) or high-temperature silicone.
Figure 26 - Venting Connection and Exterior Wall Recessing of the Horizontal Termination
* Use silicone caulking to
seal the top and sides of the
termination, up to the under-
layment, stucco, or masonry
wall surface.
Adaptor
SV4.5RCH
**For thicknesses greater than
9-1/4" (235mm), see
Table 20
.
SV4.5HT-2
Square Termination
Shown
Maximum Wall Thickness
9-1/4" (235 mm)**
Exterior Surface of Siding
Exterior Surface of
Framing
6" to 9-1/4"
(152 to 235 mm)**
1-1/4" Maximum Recess of
the Square Termination into
Exterior Finishing Material
NOTE
:
The compact termination can be used on 35” models only. All other models require the small
square termination or the horizontal square termination.
SV4.5HT-2
Square Termination
Shown
*Caulk
*Caulk
Stucco
Siding
Interior Surface of
Finished Wall
Last Vent Section. Use
Telescopic Vent Section
(SV4.5LA), If Necessary
Maximum Extent of
Vent Run Sections
Relative to Exterior
Surface of Framing
Installing the Horizontal Termination, SV4.5HT-2
or SV4.5HTSS (All Models) and SV4.5HTKCT (35”
models only)
NOTE: The compact
termination can be
used on 35” models
only. All other models
require the small
square termination or
the horizontal square
termination.
Installing the Horizontal
Termination, SV4.5HT-2
or SV4.5HTSS (All
models) or SV4.5HTKCT
(35” models only)