SuperGreen IR-14K220 Скачать руководство пользователя страница 1

 

 

 

 

 

 

 

OPERATION & INSTALLATION MANUAL  

 

 

 

 

 

 

 

IR-30, IR-234, IR-245, IR-260, IR-288, IR-14K220, IR-18K220 

 

 

 

Electric Tankless Hot Water Heater 

 

 

 

 

 

 

 

 

Содержание IR-14K220

Страница 1: ...OPERATION INSTALLATION MANUAL IR 30 IR 234 IR 245 IR 260 IR 288 IR 14K220 IR 18K220 Electric Tankless Hot Water Heater ...

Страница 2: ...ncluded Parts List 2 INTERFACE 3 IR 30 IR 234 IR 245 IR 260 IR 288 3 IR 14K220 IR 18K220 4 MOUNTING YOUR WATER HEATER 5 ELECTRICAL INSTALLATION 7 IR 30 Wiring Diagram 8 IR 234 IR 245 IR 260 and IR 288 Wiring Diagram 8 14K220 and 18K220 Wiring Diagram 9 HOW TO CALIBRATE 10 TROUBLE SHOOTING 11 WARRANTY 12 ...

Страница 3: ...PROCEDURES BEFORE CONTINUING THE INSTALLATION FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE SERIOUS BODILY INJURY OR DEATH THIS PRODUCT SHOULD BE INSTALLED BY A LICENSED ELECTRICIAN AND PLUMBER IN ACCORDANCE WITH ALL NATIONAL STATE AND LOCAL ELECTRICAL PLUMBING CODES Keep this manual in a convenient place for future reference DANGER WATER TEMPERATURE SAFETY SETTING Safety is o...

Страница 4: ...flow sensor sends the information to the temperature controller to begin modulating the heating elements to heat the water as it passes through the quartz heating tubes and to maximize efficiency If the water flow rate exceeds the maximum heating capacity of the unit the unit will reach a maximum achievable temperature based on flow rate and unit size When a reduction in the excessive flow rate is...

Страница 5: ...ter flow rate exceeds the maximum heating capacity of the unit the unit will reach a maximum achievable temperature based on flow rate and unit size When a reduction in the excessive flow rate is made the unit will achieve the set point temperature When the fixture is closed the demand stops the flow sensor sends information to the controller to turn off the power to the quartz heating elements Th...

Страница 6: ...Page 4 IR 14K220 IR 18K220 Power On Off Increase Temperature Decrease Temperature Power connection ...

Страница 7: ...ix mounting plate to wall Mark holes with pencil 2 Drill screw holes 3 Install plastic inserts into holes for appropriate fastening 4 Mount the back panel to wall using supplied screws 5 Install unit on mounting bracket and fix with 4 screw ...

Страница 8: ...mage internal sensors and components and void the warranty Use flexible lines and screw fittings only to unit A TP valve is not required in most jurisdictions Verify your local codes accordingly and if required install on outlet side only Step 4 Verify all fittings are tight and secure Open hot water source and allow water to run though the water heater for at least 1 to 2 minutes This will purge ...

Страница 9: ...G IR 14K220 14 0 240 60 AMP 2 Pole 59 2 x 6 AWG IR 18K220 18 0 240 80 AMP 2 Pole 75 2 x 4 AWG Step 1 Remove cover of the water heater carefully and locate the electrical supply on the top right hand corner facing the unit Step 2 Use the correct wire gauge that meets all NEC or country of installation guidelines based on the size of the breakers used and the length of the run Then run the set of wi...

Страница 10: ...Page 8 IR 30 Wiring Diagram IR 234 IR 245 IR 260 and IR 288 Wiring Diagram USA EUROPE ASIA GROUND Green Green Yellow Stripe HOT Black Brown NEUTRAL White Blue ...

Страница 11: ...Page 9 14K220 and 18K220 Wiring Diagram ...

Страница 12: ...h the water heaters quartz elements faster If hotter water is required simply raise the set temp and slow the water flow rate to meet your temperature needs 3 Calibrate using Gate Valve water valve at hot outlet and choose a desirable temperature by pressing the mode buttons and adjusting the gate valve until you have a comfortable water temperature and flow rate Never use the cold inlet valve to ...

Страница 13: ...Water heater is not heating at all water is flowing but the unit is not heating the outgoing water temperature is the same as the cold water supply or the digital display does NOT light up No power or incorrect wiring Make sure the breakers at main electrical panel are ON You may have a faulty breaker or unit may be wired incorrectly Flow sensor is not activating Open up the system and check to se...

Страница 14: ... the original purchase date only A repair fee will be in place depending on the unit If faster shipping service is desired the Buyer must select and pay SUCH WARRANTIES DO NOT COVER Product misuse tampering or misapplication accidental damage or improper installation Product failure caused by chemical corrosion or freezing Product failure due to lightning flood or other natural or manmade calamiti...

Страница 15: ... OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHERS Manufacturer Contact SuperGreen Inc 4501 107...

Отзывы: