ELECTRICAL SYSTEM
Dust should not enter the control box, as it will destroy the controls. Remove (blow out) any dust present.
LAVINA® 25LEU ELECTRICAL SCHEMES WITH YASKAWA INVERTER
380-400 Volt
OPERATION
INTERVAL
Daily
Every 200
Hrs.
Every 400
Hrs.
Inspect power cords, plugs and vacuum hoses, loose bolt or
screws.
X
Check the rubber buffers,
elastic element and fixing of the
holders
X
Inspect and clean the tool plate connections
X
Inspect and clean water tank, filters mesh and misting nozzle
X
X
Inspect the seal rings and bearings of the grinding units
X
Check the planetary chain and lubricate
X
X
Replace
Felt-Ring and V
‐
rings
X
Check belts and bearings
X
Figure 7.4 /scheme 1/