![Superabrasive Lavina 16 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/superabrasive/lavina-16/lavina-16_owners-manual_1402109012.webp)
Superabrasive
Owner’s Manual - Lavina 16
®
10/2009
Refers to Lavina 16
®
12
OPERATION
Preliminary Controls
Inspect the working area as explained in the safety instructions.
For wet use - fill in the water tank when the electrical cable is disconnected. Connect the vacuum
extractor to ensure that the vacuum tube is clear and it will follow the machine easily. Plug in the machine
and also make sure that the power cord is free to follow the working direction of the Lavina 16
®
.
Adjusting and Mounting Tools
Mount the tools only after ensuring that there is enough diamond bond material left. Be sure that the
plates are always clean before mounting. Always use the tool holder key for mounting or adjusting, as
seen below Adjusting and mounting are shown on Fig.12.
Figure 12
Starting the Machine
First, follow the directions in chapter Safety Devices and Safety Instructions.
Next
,
pull the emergency stop to ensure that the machine is in working condition.
Check the potentiometer and ensure that it is set at an approximate working speed.
If working wet, add water to the floor surface to prevent the tools from scratching the floor.
If working dry, omit this step, and instead, switch on the vacuum unit. Finally, hold the machine firmly and
push the start button .
Operating the Machine
Guide the machine in straight lines across the floor, and with each new line overlap a little bit of the
previously completed surface. Work at a constant speed allowing the tools time to work at a speed
appropriate for the tools’ grit size. Never stop the Lavina 16
®
machine in one spot while the tools are still
working because they will leave marks on the floor surface. When working wet, open the water tank
periodically to release water onto the floor surface. When working dry, check the floor surface periodically
to ensure that dust is not accumulating on the surface. Also, clean the vacuum if necessary.
Stopping the Machine
Stopping the machine must be done in a fluid movement. Do not stop the machine before arresting the
motor with the off button. Use only the in Emergency Switch button incase only in emergency or to switch
of power totally.
Remember
not to hold the machine in one spot before turning off the motor as the tools could damage the
surface.
Alarm
Alarm light will light incase inverter goes in alarm mode, most common is overloading motor. To reset the
mode push reset button. See chapter troubleshooting for meaning of alarm displays