WINTERIZING PROCEDURE
Important!
Whenever the ice machine is taken out of operation during the winter months, the procedure
below must be performed. Failure to do so may cause serious damage and will void all warranties.
1. Turn off water to machine.
2. Make sure all ice is off of the evaporator(s). If ice is being made, initiate harvest or wait for
cycle completion.
3. Place the ICE/OFF/WASH switch to the “OFF” position. The switch is located in the control
box.
4. Disconnect the tubing between the water pump discharge and water distribution tube.
5. Drain the water system completely.
6. On water cooled machines, hold the water regulating valve open by prying upward on the
water valve spring with a screwdriver while using
compressed air to blow all the water out of the
condenser.
7. Remove all of the ice in the storage bin and discard.