PART
REQUIRED ACTION
FREQUENCY
Body
Use a clean cloth and a non-abrasive cleaner to clean the stainless
steel body of the
charbroiler.
Wipe the polished areas with a soft cloth.
Daily
Controls
& Front
Mylar
Panel
Unit should be turned off when not in use.
It is recommended that the unit be disconnected from the gas supply by
closing the main gas valve.
Use warm, soapy water, clean cloth to wipe away food debris
on front panel and knobs.
Daily
Grates &
Radiants
Caution: When handling grates/grids or radiants, always use
insulated gloves to prevent burns.
• Place grates on
broiler
, with grid bars horizontal, facing down.
•
Turn the
broiler
on for approximately 45 minutes.
•
Turn off the
broiler
and allow it to cool for 20 Minutes.
•
Clean top and bottom surfaces of grate with a wire brush to remove
animal fats and carbonized grease.
•
Clean channels on grates with a scraper.
•
Remove grates from
broiler
. Clean top surface of radiants with the wire
brush. They may be cleaned in place.
Warning:
Do not cover the top of the grates grid during a burn off
them to warp. It will also cause damage to the valves, the knobs and the
front panel decal.
Daily or as needed
© Supera, 2013
Version 1 | June 2013 | Charbroilers
Page 9
www.SuperaCo.com
Cleaning Instructions:
• DO NOT
use any abrasive or flammable cleaning fluids.
• DO NOT
hose down, immerse or pressure wash any part of the charbroiler, excluding the catch tray.
• NEVER
use a scrubber pad, steel wool or abrasive material, or cleaners containing chlorine, iodine and ammo-
nia or bromine chemicals as these will deteriorate the stainless steel and shorten the life of the unit.
IF CLEANING THE BURNER OF THE CHARBROILER, THE MAIN GAS VALVE MUST BE SWITCHED
TO THE CLOSED POSITION. AFTER CLEANING, THE GAS LINE CAN BE SWITCHED BACK TO THE
OPEN POSITION. PLEASE FOLLOW THE LIGHTING INSTRUCTIONS IN THIS MANUAL TO RELIGHT
THE CHARBROILER’S PILOT LIGHTS.
RECOMMENDED CLEANING
It takes very little time and effort to keep the charbroiler attractive and performing at top efficiency. Wait at least
one hour for the unit and grates to cool after the unit has been turned off.
Please follow the cleaning steps
below: