background image

POSITIVE PRESSURE VENTILATOR

 

7

 

V18-BL PPV User Guide

 

Revised 9-2019 

 

 

 

CAUTION:

 

 

Do not store battery packs or 

chargers above 120°F (50°C) or in 

direct sunlight.

 

 

 

Never use charger or batteries in 

explosive atmospheres.

 

 

 

Never attempt to open the 

battery pack. If cracked or 

damaged, return it to a

 

service center for recycling.

 

 

 

Do not splash or immerse 

charger in water or other 

liquids.

 

6.

 

Charging the Battery Packs

 

- Remove Milwaukee batteries from fan.

 

- Insert in Milwaukee Charger. Use only Milwaukee brand battery chargers.

 

- When the battery pack temperature is outside the charging range (40-105°F or 5-40°C), 
 

the red light on the charger will flash and the battery will not charge.  

- Once the battery pack is within the acceptable temperature range, normal charging will 
 

take place. 

- Using the Milwaukee RapidCharger

TM

, a 12 Amp hour battery will recharge in 120 

 

minutes and an 8 Amp hour battery will recharge in 90 minutes.

 

- Other Milwaukee chargers, including units that work with vehicle DC power, may take 
 

longer to fully charge the batteries. 

 

 

7.   Maintenance and Repair 

Maintenance should only be performed by experienced and trained personnel. If you have 

any questions, please contact Super Vac before attempting any maintenance at 

www.supervac.com or 1-800-525-5224.

 

 

Be sure the ventilator is disconnected from the power source and both batteries have been 

removed before performing any maintenance or repair. The motor is of heavy-duty ball bearing 
construction. The unit is completely sealed and requires no lubrication for the life of the motor.

 

 

The ventilator blade should be specially checked for build-up of material or dirt which may cause 

an imbalance. Excessive imbalance can lead to accelerated wear on motor bearings and vibration. 

Remove front ventilator guard. Clean blade and inside housing with mild detergent and water. Do 
not use abrasives, sharp instruments or caustic solvents that may scratch or damage the fan 

blade.

 

Содержание V18-BL

Страница 1: ...VENTILATOR USER GUIDE MODEL V18 BL...

Страница 2: ...me to read this manual before operating the ventilator Save this guide for future reference CONTENTS 1 BREAKAGE OR DAMAGE DURING SHIPMENT 3 2 GENERAL DESCRIPTION AND SPECIFICATIONS 4 3 PRODUCT SAFETY...

Страница 3: ...If we filed claim here it would be sent to your local freight agent for verification and investigation This time can be saved by your filing the claim directly Every consignee is on the ground floor...

Страница 4: ...protection when operating the ventilator Never operate ventilator while fatigued Do not disassemble or modify the ventilator in any way Doing so may lead to mechanical failure or personal injury Do n...

Страница 5: ...into the ventilator intake Replace damaged or missing guards before operatingventilator Never store or carry the battery pack so that metal objects can contact exposed battery terminals Transporting b...

Страница 6: ...and run until previous battery is empty If using shore mains power use an extension cord to connect to 110 240V AC Press and hold power button until blue backlight indicates powering up When the fan...

Страница 7: ...n 8 Amp hour battery will recharge in 90 minutes Other Milwaukee chargers including units that work with vehicle DC power may take longer to fully charge the batteries 7 Maintenance and Repair Mainten...

Страница 8: ...or accident of any type or cause are not covered by this warranty All equipment manufactured by us is pre run and tested before leaving our plant and is shipped in good working order and condition We...

Страница 9: ...Revised 9 2019 9 Contact Information For parts or service information contact Super Vacuum Manufacturing Company Inc 3842 Redman Dr Fort Collins CO 80524 Phone 800 525 5224 970 297 7100 Fax 970 297 70...

Страница 10: ...718 V 18 29 003 15320 1 BUSHING BLADE V18 BD 30 032 10743 2 SCREW HH 1 4 20x3 4 SS 31 021 10523 1 MOTOR 1 HP TEAO 48VDC V18 BD 32 032 10119 4 SCREW HH M5x0 8x12 SS 33 021 10524 1 COVER MOTOR V18 BD 34...

Страница 11: ...11 V18 BL PPV User Guide Revised 9 2019 POSITIVE PRESSURE VENTILATOR 11 Exploded View...

Отзывы: