eFlo 2.0 Electronic Flow Meter Operations Manual
Super Systems Inc.
Page 11 of 39
The sensor’s IP Address settings will be changed immediately to allow it to communicate. If you
are unable to find the unit in the list of devices, it is possible that a network setting (such as
subnet mask) may be different, the unit may be connected to a different network, or the unit
may not be powered on. SSi recommends consulting an IT engineer or network administrator. If
needed, call SSi at (513) 772-0060.
Modbus Registers
The eFlo Modbus registers are as follows.
Modbus Register
Number
Description
16
Actual Flow
17
Flow Sensor mA Input Value
18
Flow Setpoint
19
Decimal Place for Display of Flow and Setpoint
20
Instrument Modbus Address
21
Not Used
22
Not Used
23
Not Used
24
Not Used
25
Not Used
26
Not Used
27
Not Used
28
Air Flow
29
Not Used
30
Not Used
31
Not Used
32
Not Used
33
Not Used
34
Not Used
35
Auto (1) / Manual (0) for Control
36
Not Used