12
11.2
Vehicles parked outside must be covered with a waterproof cover in order
to protect from sun damage and water ingress.
11.3
Do not use high pressure cleaners. They can penetrate the seals and
cause electrical faults. Cleaning with a high pressure cleaner is
dangerous.
11.4
The only other user maintenance that should be carried out is charging
and tyre inflation. The correct pressure for the tyres is:
(a)
front: 36 PSI
(b)
rear: 36 PSI
11.5
Low tyre pressure or worn tyres will affect range and handling.
11.6
All other mechanical issues or error messages should be referred to a
dealer authorised by Vmoto UK. If an error message appears, in the first
instance turn the motorcycle off and then on again using the safety switch.
12.
Troubleshooting
Fault
Likely cause of fault
Action
The vehicle is dead and the
start button does not light
1. The battery is not
connected
1. Connect the battery
2. The safety switch is in the
off position
2. Move the safety switch to
the on position
With the power on, upon
opening the throttle, the
motorcycle does not move
1. The battery is depleted
1. Charge the battery
2. The side stand is out
2..Put the side stand away
3. Parking mode is active
3. Deactivate parking mode
4. The brake is on
4. Release the brake
5. The throttle switch is
faulty
5. Contact after sales care or
dealer
6. Controller plug is loose
6. Contact after sales care or
dealer
7. Controller fault
7. Contact after sales care or
dealer
Slow speed or short range
1. Battery is low or depleted
1. Charge the battery