background image

Updated: 10 October, 2009

Page 8

REF: REI-90-0611

B1. Press

SET

until the left display shows

P1-1

, the right display shows “Temperature in degree

celcius ” of the 1

st

set upper mould, press “

” or “

” to set up the new temperature.

B2. Press

SET

until the left display shows

P1-2

, the right display shows “Temperature degree ” of

the 2nd set of upper mould, (this only exists if the have two sets of moulds) push “

” or “

to set up the new temperature.

B3. Press

SET

until the left display shows

P1-3

, the right display shows “Temperature degree” of

the printer heater, push “

” or “

” to set up the new temperature.

C. Press “SET” until, the left display shows

P2

, this represents the counter calculation mode, the

right display shows the counting mode, “LOC” means the counter reset is locked, it will

continuously count from the last figure. If “OPN” is selected, it means the counter reset to zero.

The factory setting is

OPN

.

D. Press the “SET” key until the left display will show

P3

, and the right display shows sealing

time, use “

”, “

” keys to increase or decrease the value by one unit (0.1 second). Generally,

the value is assigned between 010 and 020. It is set at 015 at the factory.

E. Press the “SET” key until the left display will show

P4

, and right display shows the cup waiting

time, this indicates the cup will wait for before moving into the sealing position. Use “

”, “

keys to increase or decrease the value by one unit (0.1 second). Generally, the value is assigned

between 005 and 015. It is set at 010 (1 sec) at the factory. (This function based on the whether

sealing film is printed or non- printed, and with or without a date printer)

F. Setting the film-length for sealing and date printing:

(1) Printed film without date printer

Press the

SET

key until the left display shows

P5

, and set the right display value to”000”.

This indicates that the film will be controlled by an eye-mark sensor.

(2) Printed film with date printer, printing once in a cycle.

Press the

SET

key until the left display shows

P5

, and set the right display value to

000

,

indicating the film is controlled by the an eye-mark sensor, press the “set” key to

P8

and

choose printer type, the date printer will print the film at the same time when sealing.

(3) Printed film and date printer, printing twice in a cycle:

Press the

SET

key until the left display shows

P5

, and set the right value to

000

, Press

the set key again till

P7

; the right display will give a value between “001~199”, set the

correct value for the distance between the 1st printing and 2nd printing, press the “set” key

to

P8

and choose printer type, (The 1st printing is operated with the sealing mould

simultaneously).

(4) Non-printed film and without date printer

Press the

SET

key until, the left display shows

P5

, and set the right value to

003

. This

indicates the film will be controlled by length counter, press the “set” key until, the left

Содержание REI-90F

Страница 1: ......

Страница 2: ...oroughly read this manual first CAUTION BURN HAZARD Cleaning and maintenance should be performed by your trained personnel only Allow unit to cool at least 90 minutes before normal cleaning If hot mac...

Страница 3: ...on 5 4 Control Panel 6 5 Resetting Computer Program 7 6 Roll Film Set Up 10 7 Date Printer Coder 10 8 Mould Removal and Replacement 11 6 1 Upper Mould 11 6 2 Lower Mould 12 9 Maintenance and Cleaning...

Страница 4: ...0L M Sealing moulds can be exchangeable for different tray for about 5 minutes only Safety Features gearless construction and safety front panel Container Photo Sensor or Manual option Film Sensor or...

Страница 5: ...ld will move to the initial eject position This power on checking procedure will take approximately five seconds The sealing film system is also checked by the machine control system at all times c On...

Страница 6: ...for use TEMPERATURE CONTROL This is to manage the temperature setting in degrees centigrade o C Up and Down to increase or decrease one unit of value Polypropylene PVC or PET films could have the def...

Страница 7: ...heater 030 220 C 130 P 1 3 Printer heater 030 220 C 100 P2 Calculator lock open Lok Lock can t rest Opn Open can set Opn P3 Sealing time 001 030 unit 0 1sec 3 sec 010 P4 Cup waiting time 000 030 unit...

Страница 8: ...position Use keys to increase or decrease the value by one unit 0 1 second Generally the value is assigned between 005 and 015 It is set at 010 1 sec at the factory This function based on the whether...

Страница 9: ...and the right display will give a value between 001 199 set the correct value for the distance between the 1st printing and 2nd printing The 1st printing is operated with the sealing mould simultaneou...

Страница 10: ...bbon Ribbon Color 100 meters Black standard Maximum Number of Alphanumeric per line 9 e g 20060918 EXP060918 Temperature Setting adjustable 50 100 C Default 100 ON OFF Using the Control Panel Printer...

Страница 11: ...your trained personnel only Allow unit to cool at least 90 minutes before normal cleaning Always wear hot pad gloves when performing machine cleaning 6 1 Upper Mould Sealing and Cutting Function Stand...

Страница 12: ...osition for the sealing and the cutting function Exchanging Simply remove the black screw from the bottom of the lower mould and pull out the lower mould 9 Maintenance and Cleaning ELECTRICAL HAZARD A...

Страница 13: ...ould cylinder sensor or limited switch Top area error E E03 Limited switch error Lower mould output stop F E04 Sealing film is used up out off position or eye mark sensor error G E05 Limited switch er...

Страница 14: ...mould moves out half way Check the jack up system The bearing roller may go out off the slide way E03 Lower mould system error Error for un smooth lower mould movement Clean both the slide ways and b...

Страница 15: ...nsor position and clean the sensor Adjust the film roll and clamp 3 Poor sealing performance Film material is not suitable for the container The heater is not clean Sealing time is too short Cutter is...

Страница 16: ...Updated 10 October 2009 Page 16 REF REI 90 0611 11 Wiring Diagram...

Страница 17: ...Updated 10 October 2009 Page 17 REF REI 90 0611...

Отзывы: