3.1 

panel functions introduction

 

 

MENU

Menu button/return button, enter the menu selection interface or previous menu. 

 

ENTER

Confirmation button, used to confirm the selected function. 

 

UP/DOWN

Upward/downward select function or Parameter increment / decrement. 

 

3.2 

Menu Overview

 

   

 

 

 

 

 

 

 

 

 

 

 

 

Содержание WKP-3603

Страница 1: ...6 3W UV 2018 03 22 This product manual contains important information about the safe installation and use of this product Please read and follow these instruction carefully and keep this manual in a s...

Страница 2: ...system Use medicinal absorbent cotton to clean it Please do not attempt to dismantle and or modify the product inner structure Otherwise would not provide 1 year of free warranty Electrical connectio...

Страница 3: ...mode static mode and LED display screen Optical System Dimming mode Dimmer 0 fast Linear dimming Dimmer 1 8 soft Non linear dimming Dimmer From 0 100 linear dimming Lens Curved surface efficiency opti...

Страница 4: ...onnection Method Please connect power as following L live wire brown wire E earth wire yellow green double color wire N null line blue wire When connecting power ensure that the voltage and frequency...

Страница 5: ...1st next device should be plugs 8 e g 1 9 17 25 Every DMX address can be reused as needed DMX address can be any data between 001 and 512 Note 1 As this fixture s DMX signal cable connection is Paral...

Страница 6: ...oduction MENU Menu button return button enter the menu selection interface or previous menu ENTER Confirmation button used to confirm the selected function UP DOWN Upward downward select function or P...

Страница 7: ...etting was preserved Exit menu static color setting will be removed Note When entered this submenu the light fixture will automatically set to the data status sent by the master other light fixtures s...

Страница 8: ...settings parameters 1 DMX 001 2 PERS 1CH 3 7 Temperature control protection State When the temperature of the LED bead plate more than 65 the light fixture begin slowly to reduce the working current...