10. Disposal and recycling
Always discharge the Li-ion battery before disposal. Use electrical tape or other approved
covering over the terminals to prevent short circuits.
Battery recycling is encouraged. Dispose of the Li-ion battery in accordance with local, state
and federal laws and regulations. Batteries may be returned to the manufacturer.
11. Troubleshooting
Problem
Possible reason
Solution
The capacity of
the Li-ion battery
has decreased
The cells within the batteries are not
properly balanced or the Li-ion battery
is worn out.
Perform one full charge cycle to
balance the cells (see chapter 5 for
balancing).
The Li-ion
battery cannot
be charged /
discharged
The Li-ion battery has been deeply
discharged. The BMS is now in “fault
condition”.
Disconnect all loads and charge the
Li-ion battery. Then press the reset
button on the BIB / BCI for at least
10-15 seconds to resolve the “fault
condition”.
The Li-ion battery has been
overcharged. The BMS is now in
“fault condition”.
Stop charging the Li-ion battery and
press the reset button on the BIB
/ BCI for at least 10-15 seconds to
resolve the “fault condition”.
The Li-ion battery has overheated.
The BMS is now in “fault condition”.
Stop charging the Li-ion battery and
disconnect all loads and wait for the
Li-ion battery to cool down. Then
press the reset button on the BIB
/ BCI for at least 10-15 seconds to
resolve the “fault condition”.
Table 12. Troubleshooting
Содержание NOMADA 12V105Ah