12
Protection mechanism
Treshold
Overvoltage (cell/pack)
3.75 / 15V
Recovery overvoltage (cell/pack)
3.65 / 14.6V
Undervoltage (cell/pack)
2 / 8V
Recovery undervoltage (cell/pack)
2.3 / 9.2V
Short circuit current
1000A
Maximum continuous discharge current
330A
Maximum charge current
80A
Maximum discharge temperature
55°C / 131°F
Minium discharge temperature
-30°C / -22°F
Maximum charge temperature
55°C / 131°F
Minimum charge temperature
0°C / 32°F
Table 9. Protection tresholds
4. Installation
4.1. General information
!
Warning!
Never install or use a damaged Li-ion battery.
!
Warning!
Never short circuit the Li-ion battery.
!
Warning! Connect to 12V systems only.
Never install multiple Li-ion batteries in series.
!
Warning!
Do not reverse connect the power cables (polarity).
4.2. Unpacking
Check the Li-ion battery for damage after unpacking. If the Li-ion battery is damaged, contact
your reseller or Super B. Do not install or use the Li-ion battery if it is damaged!
4.3. Preparing the Li-ion battery for use
!
Warning!
Do not overcharge the Li-ion battery.
!
Warning!
Do not operate the Li-ion battery beyond published maximum specifications.