INSTALLING THE RESERVE PARACHUTE
Riser/Harness connection
- Open the 6mm Mail-
lon Rapide®
- Push the toric ring
through the Maillon
Rapide®
- Twist it
1
- Push the riser con-
necting point through
the toric ring loop
- Push the riser in the
6mm Maillon Rapide®
2
- Give the toric ring a
second twist
3
- Push the riser end
loop through the Mail-
lon Rapide®
4
- Check that the risers do not move
- Close the Maillon Rapide® by hands
and tighten with a 1/4 turn using set of
pliers
- Repeat the procedure with the second
riser
5
Fastening the risers to the harness with a set of 6mm square Maillons Rapides®.