I/O CIRCUIT AND WIRING DIAGRAMS
Light Curtain
SF2-A
Safety Relay Unit
PNP output type
I/O circuit diagram
Wiring diagram
2
5
6
FSD
6
5
2
7
4
7
3
4
1
3
Load
Emitter
Receiver
Sensor circuit
Sensor circuit
Connector pin No.
Color code of mating cable
60 mA max.
(Brown)
V
(Pink) Alarm output
(Blue) 0 V
(Gray) Not connected
(Orange) Synchronization
(Orange / Black) Synchronization
Users’ circuit
Internal circuit
200 mA max.
(Brown)
V
(Gray) Test input (emission halt input)
(Orange) Synchronization
(Violet) Not connected
(Orange / Black)
Synchronization
24 V DC
15 %
(Black) OSSD
(Blue) 0 V
Users’ circuit
Internal circuit
m
1
Note: Unused wires must be insulated to ensure that they do not come into
contact with wires already in use.
m
1
Non-voltage contact or PNP open-collector transistor
or
•
Test input (emission halt input)
9 V to Vs: Emission (sink current: 2 mA or less)
Open, or 0 to
1.5 V: Emission halt
(Note)
Note: Vs is the same voltage as the voltage of the power supply to be used.
CAUTION
Use a safety relay unit or an equivalent safety control circuit for FSD.
Emitter
Receiver
4
Not connected
1
No use
7
0 V
2
V
6
Synchronization
5
Synchronization
3
Alarm output
8
Shield
(Note 3)
Connector pin No.
Color code of mating cable
F.G.
Load
Brown
Pink
Blue
Gray (Not connected)
Orange
Orange / Black
24 V DC
15 %
Shield
(Note 3)
2
V
8
Shield (Note 3)
1
Not connected
7
0 V
3
OSSD
6
Synchronization
5
Synchronization
4
Test input
(emission halt input)
Unused wires must be insulated to ensure that they do not come
into contact with wires already in use.
Conductor cross-section area of lead wire of mating cable is 0.2 mm
2
(synchronization wire) and 0.3 mm
2
(exclude synchronization wire).
Be sure to connect the shield wire to the frame ground (F.G.).
Notes: 1)
2)
3)
F.G.
Shield
(Note 3)
FSD
Orange / Black
Orange
Gray
Violet (Not connected)
Brown
Black
Blue
m
1
Test input (Gray)
OSSD
(Black)
TEST
RESET
(Note 3)
m
E: Emitter
R: Receiver
Shield
Shield
Emitter
Receiv
er
Alarm output (Pink)
V (Brown)
0 V (Blue)
0 V (Blue)
V (Brown)
Sync.
(Orange / Black)
Sync.
(Orange)
Synchronization
(Orange / Black)
Synchronization
(Orange)
24 V DC
10 %
Not connected (Gray)
Not connected (Violet)
L1
N
M
Fuse 1
Fuse 2
R
V
S2
X12
X11
S1
X3
X2
X1
A1
33
23
41
13
51
A_IN
T_IN
K2
KA
KA
KB
K2
K1
K3
K1
K3
14
52
R
Sy
E
Sy
24 34 42
L1 L2 L3
3
KB
A2
E
0 V
R
0 V
K4
R
Sy
E
Sy
E
(F.G.)
R(F.G.)
E
V
F1
Power
Ui
NPN
PNP
PE
(Note 1)
SF-AC
CONTROL-LOGIC
KA, KB: Magnet contactor
Test input polarity selection switch
Notes: 1) Connect the light curtain’s shield wire to the frame ground (F.G.), and ground the SF-AC’s PE terminal.
Notes:
2) If using the equipment with the manual reset, wire X1 to X2 as per the illustration above.
If using with the automatic reset, disconnect X2 wire and connect it to X3. In this case, reset button is not required.
Notes:
3) Use a momentary-type switch for the reset button.
Set the test input polarity
selection switch of SF-AC
to the ‘PNP’ side.
A1
FG
S
y
+
S
y
-
T-IN
A-IN
+V
0V
52
42
X12
34
X11
24
PE
14
FG
A2
S
y
-
S
y
+
S2
S1
Receiver
0V
+V
41
51
33
X2
23
X1
13
X3
Power
Test
Ui
K1
K2
SF-AC
SF-AC Terminal
arrangement diagram
SF-AC Wiring diagram (Control category 2)