Note: The sensitivity setting can be carried out even if stable sensing is not possible.

٨

٨

In case output chatter is caused by a liquid drop on the fiber head:
FX-301

(

P

), 

FX-302

(

P

), 

FX-303

(

P

), 

FX-D1

(

P

), 

FX-A1

(

P

):

Use the limit teaching, or the timer function.
Red LED type of 

FX-7 

series:

Use the sensitivity shift function or the timer function (excluding 

FX-75

).

FX-311

(

P

), 

FX-M1

(

P

), long sensing range type of 

FX-10 

series:

Turn the sensitivity adjuster further clockwise to raise the sensitivity level, or use 
the timer function.

In case the tank bottom, etc., gets sensed:

Readjust the sensitivity after setting at the actual depth at which detection is to be 
done.

Troubleshooting

Ԟ

ԝ

ON when not 
immersed

The fibers are mounted in the tank.

Ԛ

ԙ

Ԙ

Ԝ

ԛ

ON when 
immersed

Sensing condition

Step

Description

Set the mode selection switch to 'SET'.

Press the ON button.

When the sensor accepts the ON condition, the 
stability indicator (green) blinks.

The stability indicator blinks twice if the difference between the 
ON level and the OFF level is sufficient enougt to detect the 
liquid level stably. (Note)
The stability indicator blinks continuously if the difference is so 
small that stable detection of the liquid level is not possible. (Note)

Press the OFF button.

Set the mode selection switch to 'RUN'. 
Then, the set sensitivity is registered. Even if the 
buttons are pressed by mistake in 'RUN' mode, 
the registered sensitivity stays unchanged.

RUN
SIF
SET

RUN
SIF
SET

٨

This is the method of setting the sensitivity by teaching only the water absent 
condition (not immersed condition).

<Limit teaching>

Notes: 1) 

2) 

3) 

If the jog switch is pressed continuously 3 sec., or more, full auto-teaching is 
done. In case of 

FD-F8Y

, correct sensitivity setting cannot be done in full 

auto-teaching.
Also, if the mode selection switch is changed to 'RUN' while level indicators 
'4' and '5' are blinking, the incident light intensity taught at Step 

Ԛ

 is not re-

corded.
When the mode selection switch is set to 'SET' or 'MODE', the sensor is 
more susceptible to extraneous light. Hence, when sensing a liquid, ensure 
to set the mode selection switch to 'RUN'.
When the mode selection switch is changed from 'SET' to 'RUN' or from 
'MODE' to 'RUN', the set sensitivity or the contents of each mode setting are 
stored in an EEPROM. However, since the EEPROM has a lifetime, the sen-
sitivity setting cannot be done for more than 100,000 times.

Step

Level indicators

Description

SET

MODE

RUN

SET

MODE

RUN

Turn the jog switch to the '+' side.
The sensitivity is increased by 15% appox. respect to 
that set at step 

Ԛ

.

The fibers are mounted in the tank.

Ԛ

ԙ

Ԙ

Set the mode selection switch to 'SET'. The 
present sensitivity is displayed.

Ԝ

ԛ

Set the mode selection switch to 'RUN'. (Note 2)
The sensitivity level does not change even if 
the jog switch is operated.

(e.g.) The level indicators in the figure on the left show that the 

sensitivity level is in the range 720 to 729.

Press the jog switch in the fiber not immersed condition. The level in-
dicators '3' and '6' blink.
Release the jog switch within 3 sec. The lev-
el indicators '4' and '5' blink and the incident 
light intensity in the fiber not immersed con-
dition is read. (Note 1)

Press

㪫㫌㫉㫅㩷㫋㫆㩷㩾㪂㩾㩷㫊㫀㪻㪼

When using the red LED type of FX-7 series

Notes: 1) 

2) 

In order to protect the mechanism, the sensitivity adjuster idles when over 
turned, which may result in a backlash of 1 to 2 divisions.
Depending upon the sensing conditions, stable sensing may be possible at 
a position which is slightly shifted from the optimum sensitivity point.

٨

٨

٨

Adjust the sensitivity, observing the op-
eration indicator (orange).
However, since the condition for light-
ing up of the indicator depends on the 
combination of the sensing condition 
and selected MODE for L/D-ON, verify 
it from the table on the right.
The sensitivity adjuster is a 12-turn po-
tentiometer. The maximum sensitivity 
is obtained by turning it fully clockwise.
The sensitivity level indicator shows the present sensitivity level.

When using the FX-M1(P)

MODE

L-ON (ON when not immersed)

L-ON (ON when not immersed)

D-ON (ON when immersed)

D-ON (ON when immersed)

Operation 
indicator

Immersed

Not 
immersed

Sensing 
condition

: Lights off

: Lights up, 

Turn the sensitivity adjuster fully counterclock-
wise.
(Minimum sensitivity)

ڎ

Make sure that the 
operation selection 
switch is set to L-ON 
(not immersed ON).

MAX

ON

MAX

OFF

ON

MAX

Operation

Ԝ

ԛ

Ԛ

ԙ

Ԙ

Select the mode either L-ON (not immersed ON) or D-ON (immersed ON) according to your application.

Step

Sensitivity 
level indicator

Sensing method

MAX

Optimum
point

In the fiber not immersed condition, slowly turn 
the adjuster clockwise and find the point
     where the sensor is switched ON.

In the fiber immersed condition, slowly turn the 
adjuster further clockwise until the sensor goes 
into the ON state again. Once it is switched on, 
turn the adjuster counterclockwise a little and find 
the point     where it is switched OFF. 

If the sensor does not go into the ON state, 
MAX is the point     .

Set the adjuster at the center of points      and     . 
This is regarded as the optimum sensitivity point.

Fiber not immersed

Fiber  immersed

Notes: 1) 

2) 

In order to protect the mechanism, the sensitivity adjuster idles when over 
turned, which may result in a backlash of 1 to 2 divisions.
Depending upon the sensing conditions, stable sensing may be possible at 
a position which is slightly shifted from the optimum sensitivity point.

٨

٨

٨

Adjust the sensitivity, observing the op-
eration indicator (orange).
However, since the condition for light-
ing up of the indicator depends on the 
combination of the sensing condition 
and selected MODE for L/D-ON, verify 
it from the table on the right.
The sensitivity adjuster is a 8-turn po-
tentiometer. The maximum sensitivity 
is obtained by turning it fully clockwise.
The sensitivity level indicator shows the present sensitivity level.

When using the long sensing range type of FX-10 series

MODE

L-ON (ON when not immersed)

L-ON (ON when not immersed)

D-ON (ON when immersed)

D-ON (ON when immersed)

Operation 
indicator

Immersed

Not 
immersed

Sensing 
condition

: Lights off

: Lights up, 

Select the mode either L-ON (not immersed ON) or D-ON (immersed ON) according to your application.

MAX

MAX

ON

OFF

ON

MAX

Turn the sensitivity adjuster fully counterclock-
wise.
(Minimum sensitivity)

ڎ

Make sure that the 
operation selection 
switch is set to L-ON 
(not immersed ON).

Operation

Ԝ

ԛ

Ԛ

ԙ

Ԙ

Step

Sensitivity 
level indicator

Sensing method

MAX

Optimum
point

In the fiber not immersed condition, slowly turn 
the adjuster clockwise and find the point
     where the sensor is switched ON.

In the fiber immersed condition, slowly turn the 
adjuster further clockwise until the sensor goes 
into the ON state again. Once it is switched on, 
turn the adjuster counterclockwise a little and find 
the point     where it is switched OFF. 

If the sensor does not go into the ON state, 
MAX is the point     .

Set the adjuster at the center of points      and     . 
This is regarded as the optimum sensitivity point.

Fiber not immersed

Fiber  immersed

PRINTED IN JAPAN

Head Office

2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan 
Phone: +81-(0)568-33-7211  FAX: +81-(0)568-33-2631

Overseas Sales Dept.

Phone: +81-(0)568-33-7861  FAX: +81-(0)568-33-8591 

http://www.sunx.co.jp/

SUNX Limited

15%

0

OFF

ON

Turn to '+' side

Sensitivity leval

100%

High

Low

Sensitivity level

Sensitivity level with
fiber not immersed