Please refer to the instruction manual enclosed with the fiber sensor amplifier.

SPECIFICATIONS

1

Notes: 1) 

2) 
3) 

4) 

Unclear liquid may not be sensed stably.
1,000mm from the amplifier insertion end is the cutting range.
Liquid being detected should also be kept within the rated ambient 
temperature range.
The ambient temperature and pressure under which these devices are used  
are set separately.
For usage with both of these at or near the maximum permissible value, 
please contact our office.

FX-CT2

 (Fiber cutter): 1 pc.

FX-AT3

 (

Ǿ

2.2mm fiber attachment for 

FX-301

/

302

/

303

/

311

 series): 1pc.

Accessory

-49 to +490kPa

Ambient pressure 
(Note 4)

Allowable 
bending radius

Tube: R40mm or more (Do not bend 26mm length from the tip)
Fiber cable: R15mm or more

2m free-cut [Do not cut the tube (Note 2)]

Fiber cable length

Tube: Fluorine resin, Fiber sheath: Polypropylene

Material

35 to 85% RH, Storage: 35 to 85% RH

Ambient humidity

-40 to +125

͠

 (No dew condensation or icing allowed), Storage: -40 to +125

͠

Ambient temperature
(Note 3) (Note 4)

0.5mm or less (with water)

Repeatability

Liquid (Note 1)

FX-301

(

P

), 

FX-302

(

P

), 

FX-303

(

P

), 

FX-311

(

P

), 

FX-D1

(

P

), 

FX-A1

(

P

), 

FX-M1

(

P

)

red LED type of 

FX-7 

series, long sensing range type of 

FX-10 

series

FD-F8Y

Refelctive

Applicable fiber 
amplifiers

Sensing object

Type

Item

Model No.

CAUTIONS

2

٨
٨

٨

٨

٨

٨

٨
٨

Take care that unclear liquid may not be sensed stably.
Take care that the tube may stretch by maximum 2% of the total length if it is used 
at a high temperature.
Bending radius of the fiber cable must be R15mm or more (tube: R40mm or 
more). However, do not bend 26mm length from the tip.
If the bending radius is smaller than the specified value, the sensing performance 
may deteriorate.
Do not use the fiber at places having intense vibrations, as this can cause mal-
function.
Keep the fiber head surface intact. If it is scratched or spoiled, the detectability will 
deteriorate.
Ensure that any strong extraneous light is not incident on the receiving face of the 
fiber head.
Do not apply excessive tensile force to the fiber cable.
Take care that the sensor is not directly exposed to fluorescent light from a rapid-
starter lamp or a high frequency lighting device, as it may affect the sensing per-
formance.

SENSITIVITY SETTING

5

Do not move or bend the fiber cable after the sensitivity setting. Detection may 
become unstable.

Thank you very much for using SUNX products. Please read this Instruction Manual 
carefully and thoroughly for the correct and optimum use of this product. Kindly keep 
this manual in a convenient place for quick reference.

INSTRUCTION MANUAL

FD-F8Y

Liquid Level Detection Fiber

MOUNTING

3

٨

Use a commercially available fluorine resin joint, etc., 
to install 

FD-F8Y

.

Fluorine resin joint

CUTTING FIBER CABLE

4

٨

٨

٨

The fiber cables should be cut off at the ends with the fiber cutter 

FX-CT2

 

(accessory) before insertion into the fiber amplifier.
For the usage of the fiber cutter (

FX-CT2

), refer to the instruction manual 

enclosed with this product other than this instruction manual.
Do not scratch the fiber sheath while cutting the fluorine resin tube.

Protective tube

Fiber cable

10

mm

Possible 
cutting range

٨

This is the method of setting the threshold value by teaching only the water absent 
condition (not immersed condition).

<Limit teaching>

٨

٨

٨

Adjust the sensitivity, observing the op-
eration indicator (orange).
However, since the condition for lighting 
up of the indicator depends on the com-
bination of the sensing condition and 
selected operation for L/D-ON, verify it 
from the table on the right.
The sensitivity adjuster is a 12-turn po-
tentiometer. The maximum sensitivity is 
obtained by turning it fully clockwise.
The pointer shows the present sensitivity level.

When using the FX-311(P)

MODE

L-ON (ON when not immersed)

L-ON (ON when not immersed)

D-ON (ON when immersed)

D-ON (ON when immersed)

Operation 
indicator

Immersed

Not 
immersed

Sensing 
condition

: Lights off

: Lights up, 

Note: The approx. 15% amount of shift is the initial value. The amount of shift can be 

changed in the PRO mode from approx. 5 to 80% (5% step). Refer to
'

SUNX fiber sensor homepage (http://www.fiber-sensor.com)

' for the setting 

method.

When using the FX-301(P) or the FX-302(P), FX-303(P)

٨

This is the method of setting the threshold value by teaching two levels, 
corresponding to the immersed and not immersed conditions. Normally, setting is 
done by this method.

<2-level teaching>

Ԟ

ԝ

Ԝ

ԛ

Ԛ

ԙ

Ԙ

The incident light intensity appears in the digital dispaly and the setting is 
complete.

The threshold value is displayed.

If the teaching is accepted, the read incident light intensity blinks in the digital 
display and the threshold value is set at the mid-value between the incident 
light intensities in the immersed and the not immersed conditions. After this, 
the judgment on the stability of sensing is displayed.
In case stable sensing is possible: '       ' is displayed. Stability indicator 
(green) blinks.
In case stable sensing is not possible: '       ' is displayed. Stability indicator 
(green) is off.


MODE indicator / TEACH (yellow) blinks.
Press jog switch in the  fiber not immersed con-
dition.


Press jog switch in the fiber immersed condition.
If the teaching is accepted, the read incident 
light intensity blinks in the digital display.

Step

Display

Description

Press

Press


The fibers are mounted in the tank.
Press MODE key to light up MODE indicator /
TEACH (yellow).

Press

'         ' blinks in the digital display.

Step

Display

Description

Turn to '-' side

Press

Ԙ


The fibers are mounted in the tank.
Press MODE key to light up MODE indicator /
TEACH (yellow).

Press

ԛ

Ԛ


MODE indicator / TEACH (yellow) blinks.
Turn jog switch to the '-' side.

ԙ


Press jog switch in the not immersed condition.
If the teaching is accepted, the read incident 
light intensity blinks in the digital display.

ԟ

Ԟ

ԝ

Ԝ

After this, the judgment on whether the setting shift amount can be shifted or 
not is displayed.
In case shifting is possible: '         ' is displayed.
In case shifting is not possible: '         ' is displayed.

If jog switch is turned to the '-' side, '         ' scrolls (twice) 
the digital display from left to right, and the threshold level is 
shifted to a value approx. 15% lower (higher sensitivity) than 
that set at 

ԙ

. (Note)

The incident light intensity appears in the digital dispaly and the setting is 
complete.

The threshold value is displayed.

'         ' blinks in the digital display.

15%

0

100%

High

Low

Turn to '-' side

ON

OFF

Threshold value

Incident light intensity 
with fiber not immersed

Threshold value