Adjust zero-point

1

 Zero-point 

adjustment

PRESSURE SENSORS

DP5/DPH

Head-separated

DP4

DP2

DP3

DP-M

Digital Display

PE

LED Bar Display

DP4

786

PRECAUTIONS FOR PROPER USE

Measurement

4

 Pressure value 

setting

2

 Initial setting

Set ‘Display’, ‘Output
mode’, and ‘Unit’

3

 Supplementary

setting

Set ‘NO / NC’, ‘Display
cycle’, ‘Response time’,
and ‘Pressure range’

Enter Set Value 1 (P-1),
Set Value 2 (P-2), Set
Value 3 (P-3)

Commence
measurement on
completion of setting

• 

The displayed pressure when the pressure port is left
open is adjusted to zero.

• 

The sensor will automatically enter the sensing
mode when power is supplied.

• 

Let the pressure port be at atmospheric
pressure (i.e., no applied pressure condition),
and press, simultaneously, the UP and
DOWN keys continuously.

 is displayed and, when the fingers are

released, zero-point adjustment is completed
and the sensor returns to the sensing mode.

DP

4

–101.3kPa

DOWN

MODE

UP

• 

Pressure ‘Unit’, ‘Display’, and ‘Output mode’ of the outputs
are set.

• 

In the sensing mode, press key while
pressing UP key.

• 

Initial setting is displayed.

• 

If sensor is being used for the first time, 
is displayed.

• 

The settable digit blinks.

• 

The settable digit changes when UP key is
pressed and the setting is changed when
DOWN key is pressed.

MODE

DP

4

–101.3kPa

DOWN

MODE

UP

• 

‘NO / NC’, ‘Display cycle’, ‘Response time’ and ‘Pressure range’ are set.

• 

In the sensing mode, press both DOWN key
and key simultaneously.

• 

The setting item and the setting condition are
displayed alternately.

• 

The setting item changes when UP key is
pressed.

• 

The set condition of each item changes when
DOWN key is pressed.

MODE

DP

4

–101.3kPa

DOWN

MODE

UP

• 

Sets output to Set Value 1 to 3 (P-1 to P-3).

• 

Press the key in sensing mode.

• 

The mode changes in the order Set Value 1 
(P-1) setting mode, Set Value 2 (P-2) setting
mode and Set Value 3 (P-3) setting mode each
time the key is pressed.

MODE

MODE

 If key-protect has been set, make sure to release key-protect before operating the keys.

(Please refer to ‘Key-protect function’ on 

p.787

 for the procedure.)

Set Value 1 (P-1) and Set Value 2 (P-2) can be made common for all the output modes.

The setting of Set Value 2 (P-2) with respect to Set Value 1 (P-1) can only be towards the high pressure side in case of
the positive pressure type sensor and only towards the high vacuum side in case of the vacuum pressure type sensor.

The conditions which are set are stored in an EEPROM. Kindly note that the EEPROM has a life span and its guaranteed
life is 100,000 write operation cycles.

Setting

Setting procedure

1

Zero-point adjustment

3

Supplementary setting

4

Pressure value setting

2

Initial setting

 :

 :

 :

 :

Change with UP key

3rd digit

2nd digit

1st digit

Unit

Output mode

Display

 : kgf/cm

2

bar

psi

mmHg

inHg

Positive and compound 

pressure types

Vacuum

pressure type

 : kPa or

MPa

 : Hysteresis

mode

 : Window

comparator
mode

 : Forced output

mode

 : Automatic

sensitivity
setting mode

 :

 :

Digital
display

Analog
bar 
display

DOWN

DOWN

DOWN

UP

UP

: 256 ms

: 512 ms

: 1,024 ms

: 2 ms

: 16 ms

: 128 ms

: 512 ms

: 1 MPa

: 1,000 kPa

DOWN

DOWN

DOWN

DOWN

NO / NC selection

Display cycle 
selection

Pressure range 
setting (Note)

Response time 
selection

UP

UP

UP

Change with UP key

: NO 

: NC 

 Normally 
 open

(

)

 Normally 
 closed

(

)

Note: Displayable only for positive pressure type DP4-52(P).

DP

4

–101.3kPa

DOWN

MODE

UP

Press      key 

MODE

Press      key 

MODE

Press      key 

MODE

Press      key 

MODE

Sensing mode

Set Value 3 (P-3) setting mode (Note)

• 

Use the UP key and DOWN key

  to check Set Value 3 (P-3).

Set Value 2 (P-2) setting mode

• 

Use the UP key and DOWN key 

  to change Set Value 2 (P-2).

Set Value 1 (P-1) setting mode

• 

Use the UP key and DOWN key 

  to change Set Value 1 (P-1).

• 

Indicates sensing pressure.

Note: Set Value 3 is only displayed when automatic sensitivity setting mode

has been set. Furthermore, if Set Value 3 is between Set Value 1 and
Set Value 2, the UP key and DOWN key can be used to correct it.

Содержание DP4 Series

Страница 1: ...mm 60 mm 2 362 in 60 mm 2 362 in Snap fit connector is used for cable connection The cable has a snap fit connector for easy mounting and removal The connector can be easily assembled by yourself Fur...

Страница 2: ...nd the ejector is not detected as an abnormal pressure 0 Pressure Set value Output Output Time 2 ms 16 ms 128 ms 512 ms 4 steps change over Response time At 2 ms At 128 ms Mountable from four differen...

Страница 3: ...3 C5 DIN rail mounting bracket MS DP 2 Sensor mounting bracket MS DP 3 MS DP 4 Label space MS DP 5 Panel fixing screw Accessory Horizontal multiple panel mounting bracket MS DP 5 m The above illustrat...

Страница 4: ...ent temperature range 0 to 50 C 32 to 122 F within 5 F S of detected pressure at 25 C 77 F M5 female thread Front case ABS LCD display PET Rear case PBT M5 threaded part Brass nickel plated Connector...

Страница 5: ...agram Pin position Symbols D Reverse supply polarity protection diode ZD Surge absorption zener diode Tr PNP output transistor 1 3 2 ZD D 100 mA max Tr Terminal No Color code of connector attached cab...

Страница 6: ...series is a CE conformity product complying with EMC Directive The harmonized standard with regard to immunity that applies to this product is EN 61000 6 2 Note and the following condition must be me...

Страница 7: ...each time the key is pressed MODE MODE If key protect has been set make sure to release key protect before operating the keys Please refer to Key protect function on p 787 for the procedure Set Value...

Страница 8: ...than forced output mode the mode will change to pressure value setting mode After releasing the mode select key press the key again continuously until is displayed 4 sec or more Make the setting for S...

Страница 9: ...Further tighten both the right and the left screw gradually and equally so that the panel mounting bracket does not tilt 13 mm 0 512 in spanner M3 length 15 mm 0 591 in panel fixing screw Accessory Pa...

Страница 10: ...2 362 37 1 457 17 0 669 0 5 0 0 020 0 0 5 0 0 020 0 37 1 457 0 5 0 0 020 0 X 0 5 0 0 020 0 X when n unit is installed X 20 n 1 17 mm 0 669 in Note The panel thickness should be 1 to 6 mm 0 039 to 0 23...

Страница 11: ...559 Material Cold rolled carbon steel SPCC nickel plated Note Use with the panel mounting bracket MS DP 1 included with the sensor Material Cold rolled carbon steel SPCC nickel plated Note Use with th...

Страница 12: ...ke sure that the tightening torque is 1N m or less If excessive tightening torque is applied the commercial fitting may break b I O CIRCUIT DIAGRAM Pin position Pin position NPN output type Horizontal...

Страница 13: ...types Positive pressure and compound pressure types Corrective action Switch off the power supply and check the load Applied pressure at the pressure port should be brought to atmos pheric pressure a...

Страница 14: ...g mode Zero point adjustment Sensing mode UP key DOWN key Release the keys Setting procedure Sensing mode Initial setting mode Setting item selection UP key MODE key UP key Setting condition selection...