Thank you very much for using SUNX products. Please read this
Instruction Manual carefully and thoroughly for the correct and optimum
use of this product. Kindly keep this manual in a convenient place for quick
reference.
WARNING
٨
٨
٨
٨
Never use this product as a sensing device for personnel protection.
In case of using sensing devices for personnel protection, use products
which meet laws and standards, such as OSHA, ANSI or IEC etc., for
personnel protection applicable in each region or country.
DP-100
series is designed for use with non-corrosive gas. It cannot be
used for liquid or corrosive gas.
Japanese Measurement Laws prohibit the use of this product in Japan.
NAMES OF EACH PART
1
INSTRUCTION MANUAL
High-performance Digital Display
Pressure Sensor
MJE-DP100 No.0004-94V
DP-100
Series
For use outside Japan
Standard type
High-function type
PNP output type
Standard type
NPN output type
When using the analog voltage output, take care to the input impedance of
the connected device.
Furthermore, note that if the cable is extended, the cable resistance will
cause the voltage to drop.
I/O CIRCUIT DIAGRAMS
5
High-function type
Main
circuit
(Black) Comparative output 1
Users' circuit
Internal circuit
+
_
12 to 24V DC
±10%
(Blue) 0V
(White)
Analog voltage output
or external input
1k
ǡ
100mA max.
Load
Users' circuit
Internal circuit
+
_
12 to 24V DC
±10%
(Black)
Comparative output 1
Main
circuit
(White) Comparative output 2
(Blue) 0V
100mA max.
100mA max.
Load
Load
(Brown) +V
Color code of cable with connector
Main
circuit
Users' circuit
Internal circuit
+
_
12 to 24V DC
±10%
(White)
Analog voltage output
or external input
(Black) Comparative output 1
(Blue) 0V
100mA max.
5V
1k
ǡ
Load
(Brown) +V
Color code of cable with connector
Main
circuit
Users' circuit
Internal circuit
+
_
12 to 24V DC
±10%
(Black) Comparative output 1
(White) Comparative output 2
(Blue) 0V
100mA max.
100mA max.
Load
Load
(Brown) +V
Color code of cable with connector
(Brown) +V
Color code of cable with connector
Note: Do not pull by holding the cable without pressing the release lever, as this can
cause cable break or connector break.
Ԙ
ԙ
Ԛ
ԛ
㧝
<Connection connector pin arrangement>
Connector pin No.
Terminal name
+V
Ԙ
Comparative output 1
ԙ
Standard type: Comparative output 2
High-function type: Analog voltage output or external input
Ԛ
0V
ԛ
Connection method
Disconnection method
٨
Insert the cable with connector
CN-14A-C
غ
into this product's connection connector
section as shown in the right figure.
٨
Pressing the release lever of the cable
with connector, pull out the connector.
WIRING
4
<Recommended product>
Contact: SPHD-001T-P0.5
Housing: PAP-04V-S
[JST Mfg. Co., Ltd.]
Cable with connector
CN-14A-C
غ
Release lever
٨
When connecting a commercial coupler to the pressure port, attach a
12mm spanner (14mm for
DP-100-E
type) to the pressure port's hexagon
section to fix the port, and then tighten with a tightening torque of 9.8N
䊶
m
or less (M5 female: 1N
䊶
m or less). The commercial coupler or pressure
port section will be damaged if the tightening torque is excessive.
Wrap sealing tape around the coupler when connecting to prevent leaks.
PIPING
2
12mm spanner
MOUNTING
3
٨
The sensor mounting bracket (
MS-DP1-1
) is available as an option.
When mounting the sensor onto the sensor mounting bracket, etc., the
tightening torque should be 0.5N
䊶
m or less.
٨
٨
٨
The panel mounting bracket
MS-DP1-2
(optional) and
MS-DP1-4
(op-
tional), as well as the front cover
MS-DP1-3
(optional) and
DPX-04
(op-
tional) are also available.
The type of the front cover is different depending on the applied mount-
ing bracket. Use
MS-DP1-3
for
MS-DP1-2
, and
DPX-04
for
MS-DP1-4
.
For mounting of the panel mounting bracket, refer to the Instruction
Manual enclosed with
MS-DP1-2
or
MS-DP1-4
.
Sensor mounting bracket
MS-DP1-1
(Optional)
M3 (length 6mm) screws
with washers
(Accessory with
MS-DP1-1
)
Connection
connector
DP-100
type: R
1
㧛
8
+ M5 female screw
DP-100-E
type: G
1
㧛
8
+ M5 female screw
DP-100-M
type: M5 female screw
DP-100-N
type: NPT
1
㧛
8
+ M5 female screw
Pressure port
㧝
DP-100
Setting value
DOWN key
Setting value UP key
Standard type:
Lights up when compa-
rative output 2 is ON
High-function type:
Lights up when analog
voltage output is set
Output 2 / analog
voltage output oper-
ation indicator
Lights up when compa-
rative output 1 is ON
Output 1 operation
indicator
Mode selection key
Main display
Unit display
(Note)
Sub display
Note: If set the pressure unit other than 'MPa' or 'kPa', attach the unit switching label