SMG Series Analog Gateway User Manual (Version 1.5.3)
Page 35
Flash Time
Sets the time for generating a flash signal on the analog trunk. Range of value:
32~1000, calculated by ms, with the default value of 100.
Delay after Dial
Sets the delay to send the CalleeID to PBX after you pick up and dial. Range of
value: 200~2000, calculated by ms, with the default value of 1000.
Two Stages Dialing
Mode
Sets whether it is necessary to perform the two-stages dialing operation to call the
remote end via an FXO port. By default this feature is disabled.
Maximum Wait
Answer Time
The maximum time to wait the answer of the remote side for an outgoing call from
FXO port. This item is valid only when Polarity Reversal is enabled. It is calculated
by s, with the default value of 25.
Communication
without Network
Automatically routes a call to the FXO port in case of network failure or call timeout.
After configuration, click
Save
to save your settings into the gateway or click
Reset
to restore the
configurations. If a dialog box pops up after you save your settings asking you to restart the
service, do it immediately to apply the changes. Refer to
for detailed instructions.
3.5.3 Tone Detector
Figure 3-31 Tone Parameters Setting Interface
See Figure 3-31 for the Tone Parameters setting interface. By default, there are three pieces of
tone parameters on the gateway. Click
Add New
to add tone parameters manually, see Figure