Mid POWER
Digital Radio
© Sunwave MP_PS_User Manual |
6
of
46
Contact us today:
www.sunwave.com
[email protected]
This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
Note:
Only authorized person can enter the area where the antenna is installed. And the person is fully aware of the potential for
exposure and can exercise control over his or her exposure by leaving the area or by some other appropriate means. Awareness of
the potential for RF exposure in a workplace or similar environment can be provided through specific training as part of a RF safety
program
NOTE:
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two
conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that
may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est
autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit
accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Site Considerations
1.
The system delay should be taken into consideration when there are neighboring BTS sites overlapping in coverage. Normal use
of the system will not damage the base station; however, with the increase of RU during network coverage for indoor
distribution, the uplink output noise level may affect the sensitivity of the base station, which should be considered during
engineering design. Pick an ideal easy-to-reach location for installation convenience.
2.
Pick an ideal easy-to-reach location for installation convenience.
3.
Verify that there is a minimum of a 50cm radius of space around CrossFire equipment for the convenience of maintenance and
on-site inspection.
4.
Install CrossFire close to the service area for monitor and debugging.
Environmental Considerations
Humidity and temperature can adversely effort the reliability of the CrossFire system. Therefore, it is highly recommended to install
the equipment in locations with stable humidity, temperature and ventilating.
The equipment has to operate at humidity level and temperature range as follow:
Maximum humidity: 85%
AU Operating Temperature range: -10°C to +50°C
MP-PS Operating Temperature range: -40°C to +50°C
Storage Temperature range: -40°C to +70°C