Here is some specification for cable design power supply unit (PSU):
Pn = 78W
Power consumption of N2RU
Pw = 22W
If N2 consumes 95W then 5W is dissipated
in the wire (Pw)
Pin = Vin*Iin = 100W
Pin = 100W max for class 2 installation
Rw = Pw/Iw2 = 6.8992
Rw = resistance of the wire
Vin = 56V
Voltage of N2 PSU
Rw = Rd*D
D = distance of the wire (total length of
return cable)
Rd = resistance per meter of the wire
Iin = Pin/Vin = 1.786
Iin = Max injected current to not exceed
100W
Cable type
Voltage Drop
D=Rw/Rd
Max Fiber Distance
ohms/meter
2x distance between PSU and
N2RU (there and back)
Distance between PSU and N2RU
12 AWG
0.00557
1239
619
14 AWG
0.00928
743
372
16 AWG
0.0147
469
235
N2RU Configuration
Power
Max Distance @ AWG
12
14
16
2T2R - B25, B66
78W
619
32
235
2T2R - B25, B66, B7
88W
338
203
128
2T2R - B5, B25, B66, B7
95W
169
101
64
4T4R - B25, B66
98W
56
34
21
Power connector is stripped and tinned as below.