Q u i c k s t a r t G u i d e
part #82-0124-00 Rev. A
SunTech Medical, Ltd.
2/F of Building A, Jinxiongda Technology Park
Guanlan, Bao’an District Shenzhen, 518110, PRC
Tel: +86-755-2958 8810
+86-755-29588986 (Sales)
+86-755-29588665 (Service)
Fax: +86-755-2958 8829
www.CN.SunTechMed.com
SunTech Medical, Inc.
507 Airport Boulevard, Suite 117
Morrisville, NC 27560-8200 USA
Tel: + 1.919.654.2300
1.800.421.8626
Fax: + 1.919.654.2301
www.SunTechMed.com
SunTech Medical, Ltd.
Oakfield Estate
Eynsham, Oxfordshire
England
Tel: + 44 (0) 1865.884.234
Fax: + 44 (0) 1865.884.235
www.SunTechMed.com
Thank you for choosing this
Tango
M2 blood
pressure monitor.
For over twenty-five years, SunTech Medical
®
has
been the preeminent supplier of leading edge
technology and innovative products to obtain
blood pressure measurements when manual
readings are unreliable or simply not possible.
Today, we remain focused on the continual
advancement of clinical grade blood pressure
technology.
Tango
M2 is the latest in our line of
Tango
Stress
Test Blood Pressure Monitors, designed specifically
to work with your stress system.
Welcome to
Tango
M2!
Power On LED
STAT* - Start or stop STAT mode
UP - Scroll through menus & lists
SELECT - Choose Main Menu
screen & Select menu options
DOWN - Scroll through menus
and lists
DKA
TM
/OSC - Choose
auscultatory DKA
TM
mode or
oscillometric OSC mode (see the
DKA vs OSC mode section of this
guide for more info)
START/STOP - Start or stop a
measrement.
The Measurement View displays the current or most recent
patient measurements as numeric readings.
A green “running man” icon indicates that the monitor is set
to take BP readings in auscultatory (exercise) DKA™ MODE.
M e a s u r e m e n t V i e w
F r o n t P a n e l
Mean Arterial
Pressure*
Cuff Pressure
Blood Pressure
Reading
Waveform Indicator
& Display
SpO
2
Interval Indicator
& Timer
Heart Rate
Double
Product
Blood Pressure
Blood Pressure & Heart Rate
for the Highlighted Reading
SpO
2
Interval Indicator
& Timer
Heart Rate or
Double Product
R e a r P a n e l C o n f i g u r a t i o n
SpO
2
Internal ECG
Patient Cable
(Microphone)
Patient Cable
(Pneumatic)
Power On
USB-B
USB-A
RS-232
BNC External
ECG
Headphone
DC Power
Connection
The Graph View displays a summary of the most recent BP
measurements, in addition to numeric display of other readings.
G r a p h V i e w
An orange “running man” icon with a slashed circle indicates
that the monitor is set to take BP readings in oscillometric
(non-exercise) OSC MODE. The patient must remain still.
* Not available in all countries see User Manual for details.
* Press the STAT button to take repeated
blood pressure measurements for time
sensitive or emergency situations
(optional)
(optional)