Doc. Title
Author
Page of Pages
ST310U OPERATION MANUAL
JH KIM
51 of 66
Concerning
Doc. No.
Rev.
Date
Features and How to set parameters
1.08
2017/7/13
Suntech International Ltd.
Confidential Document
Field
Mark
Value
Meaning
CMD_ID
“SetOdometer=”
meter
Setting odometer.
<Example>
[command] ST300CMD;100850000;02;SetOdometer=999999999
[response] ST300CMD;Res;100850000;010;SetOdometer=999999999
7-4. Initializing Message Number
This command is used if you want to initialize sequence number of the message.
Field
Mark
Value
Meaning
CMD_ID
“InitMsgNo”
Set message number to 0.
<Example>
[command] ST300CMD;100850000;02;InitMsgNo
[response] ST300CMD;Res;100850000;010;InitMsgNo
7-4. Setting Hour-Meter
This command is used if you want to set the travelled time period.
Field
Mark
Value
Meaning
CMD_ID
“SetHMeter=”
minute
What to set the travelled time period.
<Example>
[command] ST300CMD;100850000;02;SetHMeter=999999
[response] ST300CMD;Res;100850000;010;SetHmeter=999999
Max value is
‘999999’
7-5. Initialize Circular Geo-fence
● Definition
: Request all of geo-fence parameters.
Field
Definitions
Unit Remark
CMD_ID
“InitCircleGeo”
Clear circular geo-fences.
<example>
[command] ST300CMD;600850000;02;InitCircleGeo
[response] ST300CMD;Res;600850000;262;InitCircleGeo
7-6. Requesting Circular Geo-fence
This command is used if the device is required to report to the server with all of the geo-fence parameters that are
pre-set.
Field
Mark
Value
Meaning
CMD_ID
“ReqCircleGeo”
Report the enabled circular geo-fences