Features and How to set parameters
1.00
15 Jan 2019
Suntech International Ltd.
Confidential Document
0 = None
1 = Falling Edge
2 = Rising Edge
3 = Both Edge
INPUT2_CHAT
0 ~ 9999
2bytes int Input 1 chattering time
Default = 3 sec (unit : 100 ms)
If 0, input 2 is not checked.
END OF LINE
\r\n
String
[Command]
$CMD_CHANGE_PARAM;0;0;0;0;0;0;0;0;0;0;0;0;0;0;0;0;0
5-1-5. Reset
Field
Value
Format
Description
CMD
$CMD_RESET
String
Command
END OF LINE
\r\n
String
[Command]
$CMD_RESET
5-1-6. Disconnected Check
Field
Value
Format
Description
CMD
$CMD_DISCON_CHECK
String
Command
END OF LINE
\r\n
String
[Command]
$CMD_DISCON_CHECK
[Response]
$ACK_DISCON_CHECK;ST25T (Refer to Section
5-2-3
)
5-1-7. Uart Fuel Sensor Param Request
Field
Value
Format
Description
CMD
$REQ_FUEL_PARAM
String
Command
END OF LINE
\r\n
String
[Command]
$REQ_FUEL_PARAM
[Response]
$RES_FUEL_PARAM;ST25T;0;0;0;0;0;0;0;0;0;0;0;0 (Refer to Section
5-2-9
)