11
Customized mounting method
Note: The installation methods below are based on the internal evaluation results in Suntech
Mounting
method*
Mechanical load
Installation location
Module type
Four clamps short
end mounting with
beams parallel with
long frame
Test load:
positive 5400Pa
negative 2400Pa
Safety factor: 1.5
A0 = 1/4 short frame length±50mm
B60/W Series
C54/U Series (30mm & 35mm)
Four clamps short
end mounting with
beams parallel with
long frame
Test load:
positive 2400Pa
negative 1600Pa
Safety factor: 1.5
A0 = 1/4 short frame length±50mm
B72/V Series
Four clamps short
end mounting with
beams parallel with
long frame
Test load:
positive 2400Pa
negative 800Pa
Safety factor: 1.5
A0 = 1/4 short frame length±50mm
C72/V Series
Four clamps short
end mounting with
beams underneath
the short frame
Test load:
positive 2400Pa
negative 2400Pa
Safety factor: 1.5
A0 = 1/4 short frame length±50mm
C54/U Series (30mm)