5.12.  Battery Discharge Page

To configure inverter’s shutdown settings, click on the BATTERY icon and then on ‘Shut Down’.

What this page displays:

 

ƒ

Inverter shutdown voltage set as either a voltage or %.

 

ƒ

Inverter low battery warning set as either a voltage or %. 

 

ƒ

Restart voltage set as either a voltage or %.

What you can do from this page:

 

ƒ

Adjust battery shut down (voltage or %)

 

ƒ

Adjust low battery warning (voltage or %)

 

ƒ

Adjust restart (voltage or %)

Activating Shutdown causes the inverter to enter standby-mode. It does not com-
pletely shut down the inverter. Total shutdown occurs at voltages below 19V.

The voltage displayed on the Sunsynk Parity Inverter will vary depending on whether the inverter 
is charging or discharging the batteries.

Содержание SUNSYNK-8K-SG01LP1

Страница 1: ...SG01LP1 SUNSYNK 8K SG03LP1 INSTALLER MANUAL v 11 03 30 22 Global Tech China Ltd 3 Floor Wai Yip Industrial Building 171 Wai Yip Street Kwun Tong Kowloon Hong Kong Tel 852 2884 4318 Fax 8522884 4816 ww...

Страница 2: ...ll be displayed on the inverter screen the LED indica tor fault will light up SUNSYNK 8K SG01LP1 SUNSYNK 8K SG01LP3 Australia Main Dealer HORTON SOLAR CONSULTING Pty Ltd 166a King William Road HYDE PA...

Страница 3: ...d AC Surge Protector 22 4 10 Installing the CT Coil 23 4 11 Earth Connection MANDATORY 25 4 12 Meter Connection 26 4 12 1 System Connection for the CHNT Meter EU 26 4 12 2 System Connection for the Ea...

Страница 4: ...age 50 5 13 Setting Up a Lithium Battery 52 5 14 Program Charge Discharge Times 57 5 15 Grid Supply Page 60 5 16 Connecting the DRM s 61 5 17 Advanced Settings for Paralleling Inverters 62 5 18 Solar...

Страница 5: ...mpairment that would affect their ability to follow this manual install maintain or repair this device Any untrained personnel who might get near this device while it is in operation MUST be informed...

Страница 6: ...k of electrical shock The unit is not explosion proof so it should not be installed in an explosive atmosphere Never touch electrical components immediately after the power supply has been turned off...

Страница 7: ...ines 220V single phase pure sinewave inverter Self consumption and feed in to the grid Auto restart while AC is recovering Auto earth bond feature Via a relay CONFIGURABLE Fully programmable controlle...

Страница 8: ...cators 7 CAN Port 13 Grid 2 LCD Display 8 Battery input connectors 14 Generator input 3 Function Buttons 9 Function Port 15 Load 4 DC Switch 10 Meter_CON port 16 WiFi Interface 5 Power on off button 1...

Страница 9: ...2 1 Product Size Page 9 Hybrid Inverter Installer Manual Inverter Size...

Страница 10: ...ntegrator for other possible system architectures depending on your requirements This inverter can power all kinds of appliances in home or once environment including mo tor type appliances such as re...

Страница 11: ...ty Interactive AC Output Voltage L N PE 220 230Va c AC Output Frequency 50 60Hz AC Output Rated Current 36 4Aa c Max AC Output Current 40Aa c max Max AC Output Power 8800W AC Output Rated Power 8800VA...

Страница 12: ...ION 4 1 Parts List Check the equipment before installation Please make sure nothing is damaged in the package You should have received the items in the following package Page 12 Hybrid Inverter Instal...

Страница 13: ...ct the equipment such as sulphuric gas chlorine gas acid or alkali These can cause the copper pipes and brazed joints to corrode and fail to conduct electricity reliably Areas that can cause combustib...

Страница 14: ...r unit on the wall where the height from the floors is higher than 1600mm For proper heat dissipation allow a clearance of approximately 500mm to the side 500mm above nd below the unit and 1000mm to t...

Страница 15: ...Choose the recommend drill head as shown in below pic to drill 4 holes on the wall 52 60mm deep 1 Use a proper hammer to fit the expansion bolt into the holes 2 Carry the inverter and holding it make...

Страница 16: ...Page 16 Hybrid Inverter Installer Manual 4 5 Function Port Definition...

Страница 17: ...the battery terminals 2 Use a suitable screwdriver to unscrew the bolts and t the battery connectors in then fas ten the bolt by the screwdriver make sure the bolts are lightened with torque of 5 2 N...

Страница 18: ...losing the DC Breaker disconnection device ensure the inverter unit is wired correctly A reverse polarity connection on the battery will damage the inverter 4 6 1 Recommended DC Battery Protection Pag...

Страница 19: ...ery Temperature Sensor Connection Without a remote temperature sensor lead acid batteries may undercharge or overcharge de pending on the ambient temperature of the installation environment This may r...

Страница 20: ...Page 20 Hybrid Inverter Installer Manual...

Страница 21: ...rrect terminals and ensure the wires are securely connected Model Wire Size Cable mm2 Torque value max 8kW 10AWG 8 1 2N m All wiring and cable sizes must comply with your particular country s wiring r...

Страница 22: ...Page 22 Hybrid Inverter Installer Manual 4 9 1 Recommended AC Surge Protector...

Страница 23: ...ower to the grid This feature is also known as Zero Export 1 Fit the coil sensor around the live cable on the main fuse feeding the building and run the cable back to the inverter This cable can be ex...

Страница 24: ...r Manual If the CT coil is fitted in the wrong way then this variable will have negative instead of positive val ues when the power is flowing into the house inverter Also the inverter export limiting...

Страница 25: ...n cause faults with an RCD before the inverter Since the inverter is a true hybrid then the bond must only be made when the inverter is oper ating in Islanding Mode To accommodate this Sunsynk provide...

Страница 26: ...4 12 Meter Connection 4 12 1 System Connection for the CHNT Meter EU 4 12 2 System Connection for the Eastron Meter EU Page 26 Hybrid Inverter Installer Manual...

Страница 27: ...Page 27 Hybrid Inverter Installer Manual 4 12 3 System Connection for the CHNT Meter US 4 12 4 System Connection for the Eastron Meter US...

Страница 28: ...Page 28 Hybrid Inverter Installer Manual 4 13 Wiring System for Inverter...

Страница 29: ...Page 29 Hybrid Inverter Installer Manual...

Страница 30: ...ion When selecting the PV modules you should consider the following parameters 1 Open Circuit Voltage Voc of PV modules does not exceed the maximum PV array Voc 2 Open Circuit Voltage Voc of PV module...

Страница 31: ...Page 31 Hybrid Inverter Installer Manual 4 14 3 PV Protection 4 15 Typical Application Diagram of Diesel Generator...

Страница 32: ...4 16 Single Phase 230Vac Parallel Connection Diagram Page 32 Hybrid Inverter Installer Manual 03 02 01...

Страница 33: ...Page 33 Hybrid Inverter Installer Manual 4 17 Split Phase 120 240Vac Parallel Connection Diagram 03 02 01...

Страница 34: ...03 02 01 Page 34 Hybrid Inverter Installer Manual...

Страница 35: ...4 18 Three Phase 230 400Vac Parallel Connection 03 02 01 Page 35 Hybrid Inverter Installer Manual...

Страница 36: ...Page 36 Hybrid Inverter Installer Manual 4 19 Three Phase 120 208Vac Parallel Connection 4 19 1 Connected to the Grid 03 02 01...

Страница 37: ...Page 37 Hybrid Inverter Installer Manual 4 19 2 Connected to a Generator 03 02 01...

Страница 38: ...Page 38 Hybrid Inverter Installer Manual 4 20 Three Phase 120 208Vac PCs Parallel Connection 02 01...

Страница 39: ...LED solid light Grid connection normal Normal Green LED solid light Inverter functioning normally Alarm Red LED solid light Fault Function Key Description Esc To exit the previous mode Up Increase th...

Страница 40: ...0 0 kWh 0 0 kWh 0 0 kWh 0 0 kWh 85 BATTERY IN OUT MPPT GRID SOLAR TURBINE AC load Battery Grid 1 Customer name 2 Access settings menu page 3 Access solar history 4 Access system status page 5 Access...

Страница 41: ...positive If the sign of the grid and HM home powers are not the same when the PV is disconnected and the inverter is only taking energy from the grid and using the CT connected to Limit 2 then please...

Страница 42: ...ure bellow 1 The PV modules charge the batteries 2 When the batteries reach a specific level programmable the battery power is fed into the inverter 3 The inverter can then supply power to the grid ex...

Страница 43: ...m mode press the SYSTEM MODE icon Access the advanced settings such as Paralleling and Wind Turbine press the ADVANCE icon Access the auxiliary load smart load settings press the AUX LOAD icon Access...

Страница 44: ...LCD backlight to auto dim 0 0 kWh 0 0 kWh 0 0 kWh 0 0 kWh 0 0 kWh 0 0 kWh 85 BATTERY IN OUT MPPT GRID SOLAR TURBINE AC load Battery Grid How to change the name Change the letters in each box by mov i...

Страница 45: ...annot be reset Before performing a successful Factory Reset and locking the systems the user must enter a password to allow the setting to take place The password for Factory Reset is 9999 and for loc...

Страница 46: ...ttery manufacturer documentation Note This is a global max discharge current for both grid tied and backup modes of operation and if the cur rent exceeds this value inverter will shut down with an ove...

Страница 47: ...he battery Float V for an AGM battery is 55 20V Absorption V is for an AGM battery is 57 60V Equalization V for an AGM battery is 58 80V Equalizing charge overcharge to remove sulphate crystals that b...

Страница 48: ...e Grid side or to the Gen connection When connect ed to the Grid Input the inverter will consider the power coming from the generator as Grid Supply Users should make sure this power goes to the LOAD...

Страница 49: ...Page 49 Hybrid Inverter Installer Manual...

Страница 50: ...a voltage or Restart voltage set as either a voltage or What you can do from this page Adjust battery shut down voltage or Adjust low battery warning voltage or Adjust restart voltage or Activating S...

Страница 51: ...voltage is needed This period of the charging process is called absorption This occurs when the charging of a battery has reached reached 80 of its capacity The remaining charge equals 20 approxi mat...

Страница 52: ...the Lithium option is selected under Batt Type The type of communion protocol Approved batteries What you can do from this page Set up you Lithium ion battery After installing a lithium battery check...

Страница 53: ...pproved by Sunsynk With some types of lithium battery the BMS cannot be controlled by the Sunsynk inverter In this case treat the battery as a lead acid type and set the charging and discharging proto...

Страница 54: ...oda H4850M RS485 7 VISION Group V LFP51 2V100Ah 5KW CAN 13 VLFP51 2V200Ah 5KW CAN 13 Alpha Ess M4856 P CAN 0 SMILE BAT CAN 0 GSL ENER GY GSL051100A B GBP2 CAN 0 GSL051200A B GBP2 CAN 0 GSL051280A B GB...

Страница 55: ...00 RS485 16 Deye SUNB 5 0 C01 48 PC CAN 0 SUNB 5 0 E01 48 PC CAN 0 SUNB 5 0 G01 48 PC CAN 0 AOBOET Uhome LFP 5000 CAN 0 Uhome LFP 2400 CAN 0 Wattsonic Li LV battery series CAN 14 KODAK FL5 2 CAN 0 Fox...

Страница 56: ...facturer are followed If you are using lead acid batteries then follow the equation of C x 0 25 which means that the maximum charge or discharge you can apply to a battery is a quarter of the AH ratin...

Страница 57: ...hold loads Solar Export Set the power limits to supply only the loads connected to the LOAD port Priority to Load Only What you can do from this page Set a real time to start and stop charging or disc...

Страница 58: ...side of the inverter 4 Zero Export Power is the amount of power flowing from the Grid to the Inverter Set this value to 20 100W to instruct the inverter to always take the prescribed amount of pow er...

Страница 59: ...Setup Home Page If the Use Timer function is activated then the inverter will use the battery power according to your settings when the Grid is present If this function is not set the batteries WILL O...

Страница 60: ...Grid type normally 230V three phase What you can do from this page Set the Minimum Grid Input Voltage Grid Vol Low Set the Maximum Grid Frequency Grid Hz High Set the Minimum Grid Frequency Grid Hz L...

Страница 61: ...rter Installer Manual 5 16 Connecting the DRM s This can be selected under advance settings This can be selected under advance settings 1 DRM 1 5 2 DRM 2 6 3 DRM 3 7 4 RDRM 4 8 5 Ref 0 6 D Ground 7 Ne...

Страница 62: ...hich the inverter will be paralleled Set the Modbus SN for paralleling The Sunsynk parity inverter can be wired standalone or where more power is required it can be connected in parallel either single...

Страница 63: ...rs to the latest and the exact same firmware version IMPORTANT All inverters in a parallel system must have their own isolating load breaker before it goes to the parallel breaker to ensure while prog...

Страница 64: ...quences of not setting one inverter in a parallel mode It can damage the inverter Q4 What are the consequences of having more than one Master Inverter or having no inverter set as Master It can damage...

Страница 65: ...rly and total solar power produced Access this page by clicking on the Solar Turbine icon on the Home Page 5 19 Grid Power This page shows the Daily Monthly Yearly and total grid power export or consu...

Страница 66: ...w shows the maximum current depending on the voltage of the wind turbine DO NOT use a wind turbine that exceeds 400V Use a self breaking wind turbine Once the batteries are fully charged and the inver...

Страница 67: ...unt the output Most wind turbines are three phase PM type Therefore either a wind turbine controller or a direct connection to the MPPT via a simple protection circuit will be required 5 21 Advanced S...

Страница 68: ...4kW Zero Export Tick this box to stop exporting power produced by the Aux Load Gen Peak Shaving Tick this box to use peak power shaving 5 22 Advanced Settings for Peak Shaving To configure Peak Power...

Страница 69: ...nverter 3 On grid Power Generation Date 4 The problem description including the fault code and indicator status displayed on the LCD with as much detail as possible 5 Owner s contact information Error...

Страница 70: ...les are correctly connected F42 AC line low voltage Grid voltage fault 1 Check if the voltage is in the range of standard voltage in specification this can be adjusted via the grid set up page 2 Check...

Страница 71: ...OverCurr_Failure F46 AC_UV_UnderVolt_Fault F15 AC_OverCurr_Failure F47 AC_OverFreq_Fault F16 GFCI_Failure F48 AC_UnderFreq_Fault F17 Tz_COM_OC_Fault F49 AC_U_GridCurr_DcHigh_Fault F18 Tz_Ac_OverCurr_F...

Страница 72: ...ncerning safety and electromagnetic compatibility Before leaving the factory all inverters undergo rigorous testing to ensure the inverter can operate reliably as presented in Chapter 3 Technical Spec...

Страница 73: ...tallation engineer must have completed the Earth Bond RCD and earth leakage tests checked that the solar panel Voc voltage does not exceed 480V and checked the battery voltage Power ON Sequence 1 Swit...

Страница 74: ...harge is within the C rating of the battery Too high will damage the battery Check the battery BMS is communicat ing with the inverter This is the heart of the system this controller everything Ensure...

Страница 75: ...ce a year for dusty environments this may need to be carried out weekly all the cooling fans air ducts are cleaned and dust free Check if there are no fault codes and Lithium battery communication is...

Страница 76: ...S NZS3000 for the cable from the switchboard to the IES If an RCD is installed the engineer must 1 Disconnect all live conductors including both active and neutral conductors and 2 Be of the type spec...

Страница 77: ...nnection for the Data Logger please refer to the App User instructions The Data Logger should be connected to the bottom of the inverter via the connection socket marked WIFI For more information trai...

Страница 78: ...g 171 Wai Yip Street Kwun Tong Kowloon Hong Kong Tel HK 852 2884 4318 Fax 852 2884 4816 Tel UK 44 151 528 9945 Tel SA 27 1108 39837 sales globaltech china com Audio Training manuals on Apple Pod Cast...

Отзывы: