Commissioning

1.

Open the cover 

1,

 remove the filter sponges 

7

 and wash them.

2.

Wash the filter mat 

8.

 And place it back into its exact position.

3.

Place the filter at least 2 metres away from the pond’s edge, on a solid underground, if a UV
lamp is in use. The filter must stand horizontally, to prevent any overflow happening.

4.

The outlet hose of the water cycle needs to be placed into the pond and the hose for the pol -
luted water to runaway from should be placed into a sewage drain or into a flower bed with a
slope for the water to run off.

5.

Saw the stepped hose adapter 

20

 to the required diameter.

6.

Then place the hose onto the stepped hose adapter 

20

 and secure it with a hose clasp 

7.

Place a gasket 

19

 on the thread of the stepped hose adapter 

18.

 Then push the thread of the

stepped hose adapter 

18

 through the water outlet and place another gasket 

19 

onto the thread

and screw the stepped hose adapter 

18

 onto the thread. 

8.

Connect the other end of the hose with the pump.

9.

For the normal filter operation, leave the sealing cover 

17

 closed with a gasket 

15.

 If you wish

to install a 2 inch hose permanently, remove the sealing cover and install the hose.

10.

Install the top cover.

11.

Connect the pump to electricity. The filter will start working then.

 Note

:

A bio filter is a biological filter system and needs, if newly installed, some weeks until it reaches its full
biological efficiency.

Cleaning and Maintenance
Attention! Before carrying out cleaning or maintenance work always disconnect the device!

The device should be cleaned only if required – see the amount of pollution via the water level indic-
ator 

2.

 Chemical cleaning agents must not be used because the bacteria in the filter sponge can be

destroyed. As soon as the float of the dirt indicator is visible, disconnect the device and open the head
cover. Remove the filter sponges from the frame holder 

5.

 Press the filter sponges carefully together a

several times against their frame 

6

/

9.

 If necessary, rinse the filter sponges with clean tap water. Open

the cover of the dirt outlet till the water has completely drained off.

The device may not when it reaches temperatures of under 8°C or above 40°C! In this case, empty the
device and carry out an effective cleaning. Remove all filter materials in order to dry them. In winter
keep the filter materials in a dry place, where according parts will not rust. Cover the filter housing so
that no rain water can reach it. Empty all hoses, pipes and connections, if possible.

© by WilTec Wildanger Technik GmbH 

Item 50107, 50108, 50114 

Page 5 

http://www.WilTec.de
http://www.aoyue.eu

 

11 2020

-1

http://www.teichtip.de

Содержание CBF-350

Страница 1: ...low the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can diff...

Страница 2: ...s can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH K nigsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pick u...

Страница 3: ...emperature of the pumped liquid should not exceed 35 C during constant op eration The filter is solely to be used for the filtration of garden pond water The filter is not suitable for the filtration...

Страница 4: ...itres per hour This means that an example pond with 100 000 litres volume needs to be filtered once entirely per 10 hours Thus in 24 hours the pond water needs to be filtered 2 4 times by running thro...

Страница 5: ...mp to electricity The filter will start working then Note A bio filter is a biological filter system and needs if newly installed some weeks until it reaches its full biological efficiency Cleaning an...

Страница 6: ...Explosion view and parts list by WilTec Wildanger Technik GmbH Item 50107 50108 50114 Page 6 http www WilTec de http www aoyue eu 11 2020 1 http www teichtip de...

Страница 7: ...arse sponges 18 Oxygen feed 9 Sponge frames 19 Inlet O ring 10 Outlet 20 Stepped hose adapter Important notice The reprint or reproduction even of excerpts and any commercial use even in part of this...

Отзывы: