Controller unit

The controller consists of hook, panel, touch buttons and fixed foot.

Switch function
After the power is switched on, touch “START-STOP”, control the pump switch.

Attention:

 please cut off the power if you do no use the pump for a long time.

Adjust the gear level

Touch “DOWN” or “UP” to adjust pump gear. Consult the detailed performance data below:

Model

Power supply

Gear level

Power

 (W)

Flow rate

 (

h

)

Max. lift-

ing head

(m)

50982

(CET-8000)

220–240 V,

50 Hz

SP01

18

3500

1.6

SP02

23

4000

1.9

SP03

28

4600

2.3

SP04

35

5000

2.7

SP05

42

5400

0.1

SP06

51

5800

3.5

SP07

60

6200

3.9

SP08

66

6700

4.5

SP09

73

7200

4.8

SP10

80

8000

5.4

Feeding function

Long press “UP” until the buzzer sounds twice; delay start is activated. You have 10 min to
feed the fish. Operation is the same if you want to cancel this delay start.

© by WilTec Wildanger Technik GmbH 

Item 50982, 51192

Page 5 

http://www.WilTec.de
http://www.aoyue.eu

 

03 2021

-1

http://www.teichtip.de

Содержание 50982

Страница 1: ...llow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can dif...

Страница 2: ...ages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH K nigsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pic...

Страница 3: ...ransport any liquids other than water Attention The pump will automatically stop working if overloaded or running without water The controller is not water proof put it in a dry and well ventilated pl...

Страница 4: ...ectrical circuit with the data on the model plate these data must correspond 3 Connect the pipeline if needed Attention The piping system must not contain bubbles Hose connection diagram is as follows...

Страница 5: ...supply Gear level Power W Flow rate h Max lift ing head m 50982 CET 8000 220 240 V 50 Hz SP01 18 3500 1 6 SP02 23 4000 1 9 SP03 28 4600 2 3 SP04 35 5000 2 7 SP05 42 5400 0 1 SP06 51 5800 3 5 SP07 60 6...

Страница 6: ...n the pump will power off until re connect the power Meanwhile the alarm buzzer will sound The pump will cut off power automatically and immediately if the impeller is blocked and the alarm buzzer wil...

Страница 7: ...er in the pump should be discharged immediately in order to prevent a freezing damage Troubleshooting Problem Cause Solution Pump does not run No power supply Connect the power Burning machine Change...

Страница 8: ...e 9 Motor with cable 3 Outlet 10 Rear cover 4 Seal circle 11 Handle 5 Impeller cover 12 Rubber foot 6 Rotor set 13 Gear box with cable 7 O Ring by WilTec Wildanger Technik GmbH Item 50982 51192 Page 8...

Страница 9: ...out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment By contributing to the correc...

Отзывы: