SunSun 50312 Скачать руководство пользователя страница 4

 

© by WilTec Wildanger Technik GmbH  

Item 50312

–50317 

Page 4 

 

http://www.WilTec.de

 

http://www.aoyue.eu 

 

09 2021

-1

 

http://www.teichtip.de

 

 

Resistance 
 

 

The maximum temperature of the pumped liquid should not 35 

 in continuous oper-

ation. 

 

The  transport  of  aggressive  fluids  (acids,  bases,  etc.)  as  well  as  of abrasive  substances  (for 
example sand) must be avoided. 

 
 

Electrical connection 
 

 

The electrical connection is made to an earthed socket 230 V ~ 50 Hz. Fuse min. 6 A. 

 

The motor is protected from overcharge and blockage with the help of the built-in thermal motor 
protection. When overheated, the pump motor is automatically switched off by the thermal pro-
tection; after cooling down, the pump automatically re-starts. 

 
 

Mains connection 

 
The pond pump that you have purchased is already equipped with a protection plug. The pump is meant 
to be connected to a 220/230 V~50 Hz safety socket. Make sure that the socket is sufficiently protected 
(min. 6 A) and fully functional. Plug in the plug, the pump is operational. 
 
 

Installation 

 

1.  Make sure that the existing mains voltage and frequency match the specifications on the name-

plate. 

2.  Do  not  place  the  pump  directly  into the  pond  mud.  Place  it  on  a  stone  to  avoid  that  mud  be 

sucked in. 

3.  Check the pump head (maximum depth). The corresponding value is given on the nameplate, 

too. 

4.  The pump is installed the following way: either in a stationary position with a fixed pipeline or in 

a stationary position with a flexible pipeline. 

5.  Place the cable in a safe manner in order to exclude any danger of it being damaged. 
6.  Modify the water fountain shape by changing the position of the adjusting screw of the fountain 

head. 

7.  The flow rate can be adjusted with the help of the 3-way valve. 
8.  Connect the pump to the power supply. 
9.  The pump works until it is disconnected again. 

 
 

Initial operation 

 
After thoroughly reading the instructions for installation and use, you can operate the pump; obey the 
following hints: 
 

 

Check if the pressure line is properly attached. 

 

Check if the electric source has 230 V~50 Hz. 

 

Check if the socket is in a good condition. 

 

Make sure that neither humidity nor water may get into contact with the mains connection. 

 

Place the pump beneath the surface of the water. 

 

Avoid any running dry of the pump. 

 

Never operate the pump without a filter basket; a filter basket protects the pump against any 
coarse dirt that would obstruct the pump. 

 

 

Содержание 50312

Страница 1: ...tion similar may vary depending on model Please read and follow the operating instructions and safety information prior to initial operation Technical changes reserved Illustrations functional steps a...

Страница 2: ...m https www wiltec de contacts The most recent version of this manual in several languages can be found in our online shop https www wiltec de docsearch Our postal address is WilTec Wildanger Technik...

Страница 3: ...ice if the safety appliances are damaged or worn out Never override safety regulations Only use the device accordingly to the intended purpose stated in this manual You are responsible for the safety...

Страница 4: ...s on the name plate 2 Do not place the pump directly into the pond mud Place it on a stone to avoid that mud be sucked in 3 Check the pump head maximum depth The corresponding value is given on the na...

Страница 5: ...nd parts list Name 1 Fountain top piece 1 2 Fountain top piece 2 3 Connection tube 4 O ring 5 Connection tube large 6 Insert nut 7 Gasket 8 Outlet 9 Outlet nut 10 T piece regulator 11 Flow rate regula...

Страница 6: ...Connections Weight Size CTP 2803 50312 230 50 10 3000 2 19 25 1 33 1 2 7 172 113 126 CTP 3803 50313 20 3600 2 8 2 7 172 121 632 CTP 5003 50314 30 5000 3 3 3 188 131 149 CTP 6003 50315 40 6000 4 2 3 18...

Страница 7: ...tor housing by 90 Fig 4 to remove it 6 Remove the rotor to clean it Fig 5 7 To clean the individual parts use a soft brush or a sponge and clean them under running water 8 Check the correct seat of th...

Страница 8: ...countries of the European Union and other European countries with a separate waste collection system for these devices The symbol on the packaging or the product itself indi cates that this product mu...