Step 13

 Press 

the 

SET 

button again to move onto the 

SIXTH PERIOD     

. This is the final    

 

 

period. This would be when you would want to turn off your heating at night. 

  Press the     or    arrow to set the time you want the heating to switch off.

Step 14

 Press 

the 

SET 

button again to set the setback temperature. Anything below 16°C and    

 

 

the underfloor heating will not come on. Use the     or    arrow to set the temperature.

Step 15

 

Saturday & Sunday (6 & 7) will have to be programmed separately. Repeat 

Steps 3-14

  

 

 

to program Saturday & Sunday.

Step 9

 Press 

the 

SET 

button again to move onto the 

FOURTH PERIOD       

. This would be  

 

 

when you would want to turn off your heating in the afternoon. Press the     or    arrow  

 

 

to set the time you want the heating to switch off.

Step 10

 Press 

the 

SET 

button again to set the setback temperature. Anything below 16°C and    

 

 

the underfloor heating will not come on. Use the     or     arrow to set the temperature.

Step 11

 

Press the 

SET 

button again to move onto the 

FIFTH PERIOD       

. This would be when  

 

 

you would want to turn on your heating on in the evening. Press the     or    arrow to set  

 

 

the time you want the heating to switch on.

Step 12

 

Press the 

SET 

button again to set the target temperature. An adequate temperature    

 

 

would be anywhere between 24-28°C. Use the     or     arrow to set the temperature.

To access the advanced settings simply 

PRESS

 and 

HOLD 

the      &     arrow. You will be in advanced 

settings when you see CL in the top right hand corner and a 0 underneath. To cycle through the 
advanced settings press 

SET

. Press the     or    arrows to alter the settings. Press 

OK

 to exit

Advanced Settings

Brackets indicates 

the factory default 

setting

Description

CL (0)

Allows you to alter the display temperature by +/- 4°C

BL (1)

Allows you to turn the backlight on or off, 1 being ON and 2 being OFF

AH (35 

°

C)

This option will let you set the maximum temperature you would like to set the 
floor (F) or air sensor to (R/RF) to. Maximum for floor (F) is 20-60°C air (R/
RF) is 20-35°C

FL (5 

°

C)

This option will let you set the minimum temperature you would like to set 
the floor (F) or air sensor to (R/RF) to. Minimum for floor (F) and air (R/RF) is 
5-20°C

FH (40 

°

C)

This option lets you set the floor sensor temperature limitation 20-60°C

HE (FA)

Allows you to set Fast Heating (FH) or Slow Heating (SH)

PS (3)

Allow you to turn off programming (0), program 5 days (Mon-Fri) as a block 
and Saturday and Sunday individually (3) or program 7 days individually (7)

CS (6)

Allows you to set 4 programmed events per day (4) or 6 events (6)

Ld (H)

Allows you to set the output load

3