Press the forward arrow button at the bottom of the
screen to advance to the next weld head setup step.
You can always end the setup process by pressing the
Close Button.
TIMING
The fourth step in setting up the weld head is
to set the desired Squeeze Time and Hold Time. These
optional delay times can set up to 2000 ms.
Squeeze Time
Once the weld head reaches the weld point, it will wait
the allotted time before initiating the weld discharge.
This extra time can be useful to verify correct position
-
ing.
To set the Squeeze Time, press the Squeeze Time box.
A pop-up window will appear. Enter the desired time in
milliseconds by using the slider bar or by entering the
number using the number pad. Press the Enter Button
to close the box.
Hold Time
Once the weld discharge is complete, the servo will
maintain position for the allotted time before returning
to hover point. This can help give the weld spot time to
cool before removing pressure if necessary.
To set the Hold Time, press the Hold Time box. A
pop-up window will appear. Enter the desired time in
milliseconds by using the slider bar or by entering the
number using the number pad. Press the Enter Button
to close the box.
Once the desired Squeeze Time and Hold Time has
been entered, choose the right arrow button at the
bottom of the screen to continue. To end the setup
process, press the Close Button.
Figure 18.1. The fourth step in setting up the weld
head is to set the desired Squeeze Time and Hold
Time in the Timing Screen.
Содержание PicoDC
Страница 1: ...Direct Current Resistance Welder Users Guide 20210615 PART 1230 Pic...
Страница 4: ...Users Guide Pic...
Страница 41: ...Questions Call or Text 1 801 658 0015 37 The Micro Welder Experts...
Страница 42: ...38 Questions Call or Text 1 801 658 0015 Users Guide Pic...
Страница 43: ...Questions Call or Text 1 801 658 0015 39 The Micro Welder Experts...