The display will now show the archive data from the previous 30 days. The up/down hotkeys can be
used to scroll through the archive.
Each day in the archive will show the following data:
•
Yield: the total energy input to the system from the solar array (kilowatt hours). Note that this
is not necessarily the total energy generated by the solar array; if the batteries are fully
charged, any excess power from the solar array will not be included in that day’s yield.
•
PV (Pmax): the highest power generated by the solar array (watts).
•
PV (Vmax): the highest voltage generated by the solar array (volts).
•
Battery (Vmin): the lowest battery voltage (volts).
•
Battery (Vmax): the highest battery voltage (volts).
•
Battery (Imax): the highest battery current (amps).
•
Charge time (Bulk): the total time spent charging the batteries from a depleted state (hours
and minutes).
•
Charge time (Abs): the total time spent charging from a moderately depleted state (hours and
minutes).
•
Charge time (Float): the total time spent top-up charging the battery to maintain charge at
maximum (hours and minutes).
•
Last error: any errors detected by the Battery Protect.