SunStar STARGLO SG10-L5B Скачать руководство пользователя страница 13

Form #43219020
June 08

12

following diagram. Attach the side panels as shown. Attach the end panels so that the end flanges of the end panels overlap
the side panels. Attach the side panels and end panels together with the screws provided in the kit. Attach the remaining
screws as shown in Detail A. This is to ensure that the Parabolic Reflector Extension is securely attached to the reflector. The
clearances to combustibles (shown on the clearance label that is secured to the reflector on the control end of the heater and
in Section 5 of these instructions) must be closely observed.

Please order the Parabolic Reflector Extension Kit using the Part

Numbers below:

Model No.

Parabolic Reflector

Extension Kit Number

SG3, SG4

#43822010

SG6, SG8

#43822020

SG10, SG12

#43822030

SG13, SG14, SG15

#43822040

14)

OPTIONAL PROTECTIVE REVERB SCREEN

The optional protective Reverb Screen acts as a safety net in the
unlikely event that the ceramic tile assembly is broken by an outside
force. In addition, it increases the overall emissivity of the radiating
surface with a blackbody radiation effect. It is recommended in
high-traffic areas as well as where improved radiant output is
desired.

Please order the Protective Reverb Screen using the Part

Numbers listed to the right:

15)

REPLACING PARTS

At all times when parts are being replaced, ensure that both the gas and electrical supplies are disconnected. Various parts
are available from the factory for replacement by a licensed service person. Refer to the exploded parts guide in Section 16
for all replacement parts.

16)

INSTALLATION DATA

Date of
Installation:

Number of
Heaters in System:

Heater Serial Number:

Heater Model:

SG

N = Natural Gas

L = Propane Gas

17)

REPLACEMENT PARTS GUIDE

ITEM#

PART #

DESCRIPTION

ITEM#

PART #

DESCRIPTION

1

30333040 Valve VR8205A-2081 @ 10” W.C. – Propane Gas

17

43908010

Frame Assembly

(1 Burner Unit)

2

30333050 Valve VR8205A-2123 @ 6” W.C. – Natural Gas

18

43908020 Frame Assembly

(2 Burner Unit)

3

30279000 Transformer AT120B1051

19

43908030 Frame Assembly

(3 Burner Unit)

4

30632030 Spark Module, Fenwal #35605-950-0150

20

43908040 Frame Assembly

(4 Burner Unit)

Model No.

Reverb Screen

Kit Number

SG3, SG4

#43876010

SG6, SG8

#43876020

SG10, SG12

#43876030

SG13, SG14, SG15

#43876040

Содержание STARGLO SG10-L5B

Страница 1: ...ent this manual to the owner when you leave the job site WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operation and maintenance instructions thoroughly before installing or servicing this equipment IMPORTANT SAVE THIS MANUAL FOR FUTURE REFERENCE SUNSTAR HEATING PRODUCTS INC Post Office Box 36271 28236 306...

Страница 2: ...radiant ceramic heater for use in locations where flammable gases or vapors are not generally present as defined by OSHA acceptable limits and is intended for the heating of nonresidential spaces SAFETY REQUIREMENTS The heater area must be kept clear and free from combustible materials gasoline and other flammable vapors and liquids This heater is designed for use with one type of gas LPG or Natur...

Страница 3: ... to combustible materials vehicles parked below lights overhead doors storage areas with stacked materials sprinkler heads gas and electrical lines and any other possible obstructions or hazards Consideration also must be given to service accessibility The heater when installed in aircraft hangars and public garages must be installed in accordance with ANSI NFPA 409 latest edition Standard for Air...

Страница 4: ...e at lower temperatures are protected to prevent degradation Clearances to combustibles are posted on the reflector near the control end of the heater In locations used for storage of combustible materials where they may be stacked below the heater NFPA 54 requires that the installer must post signs that will specify the maximum permissible stacking height to maintain the required clearances from ...

Страница 5: ...58 lbs 17 SG15 N5B 155 000 4 38 n a 58 lbs 18 SG3 L5B 32 000 1 n a 52 30 lbs 12 SG6 L5B 65 000 2 n a 52 35 lbs 13 SG10 L5B 100 000 3 n a 52 48 lbs 15 SG13 L5B 140 000 4 n a 52 58 lbs 17 MODEL SUFFIX Gas Type Ignition System GAS PIPE CONNECTION N Natural L Propane 5 Direct Spark 115 Volt 0 40 Amp 60 Hz 1 2 NPT Female One Orifice Per Burner MOUNT HEATERS AS HIGH AS POSSIBLE Minimums are shown as a g...

Страница 6: ...C or 1 2 P S I If the line pressure is more than the maximum supply pressure then use a line regulator as indicated in the following illustration or a line regulator which corresponds to the supply pressure 6 If a second stage regulator is used and gas seeps through it the redundant combination gas valve is designed to lock out Pressure build up in the supply lines prior to the heater must be rele...

Страница 7: ...RESSURE TABLE SUPPLY PRESSURE HEATER MODEL GAS TYPE MANIFOLD PRESSURE Minimum Maximum SG 3 4 6 8 10 12 14 15 Natural 6 W C 7 W C 14 W C SG 3 6 10 13 Propane 10 W C 11 W C 14 W C Minimum permissible gas supply pressure for purpose of input adjustment 8 ELECTRICAL CONNECTIONS 1 All electric wiring shall conform to the latest edition of the National Electrical code ANSI NFPA No 70 or the code legally...

Страница 8: ...eight and temperature difference is as follows SG3 0 49 s f SG10 1 48 s f SG4 0 57 s f SG12 1 72 s f SG6 0 98 s f SG13 SG14 1 97 s f SG8 0 98 s f SG15 2 30 s f The General Ventilation Rules outlined in ASHRAE GUIDE AND DATA BOOK should be observed when locating vents Exhaust vents must be located at the highest point above and in the vicinity of the heaters and the inlet vents must be located belo...

Страница 9: ...itter shows signs of collecting any foreign material on its surface or in the ports or when anything obstructs the venturi or the screen Maximum heating efficiency and clean combustion will be maintained by keeping the emitter and burner clean To clean the heater follow these instructions 1 Turn off all electrical and gas supply to the heater 2 Clean the reflector 3 Remove the main burner orifice ...

Страница 10: ...ers The thermostat sensing bulb is incorrectly placed The thermostat is out of calibration Conduct heat loss and add heaters or other source of heat as necessary Reposition as necessary for proper operation NOTE The sensing bulb should be shielded from direct radiation to prevent short cycling of the heater Recalibrate if possible or replace Flames flaring up outside of emitter surface The gas pre...

Страница 11: ...Form 43219020 June 08 10 C TROUBLESHOOTING CHART Continued ...

Страница 12: ... PARABOLIC REFLECTOR EXTENSION ASSEMBLY The heater is completely factory assembled and requires no field assembly If the optional parabolic reflector extension is utilized locate and identify the end panels and side panels as shown in the ...

Страница 13: ...all emissivity of the radiating surface with a blackbody radiation effect It is recommended in high traffic areas as well as where improved radiant output is desired Please order the Protective Reverb Screen using the Part Numbers listed to the right 15 REPLACING PARTS At all times when parts are being replaced ensure that both the gas and electrical supplies are disconnected Various parts are ava...

Страница 14: ...13 43847010 Reflector for SG3 SG4 29 42052010 Connection Wire Diagram Not Shown 14 43847020 Reflector for SG6 SG8 15 43847030 Reflector for SG10 SG12 16 43847040 Reflector for SG13 SG14 SG15 LIMITED WARRANTY SunStar Heating Products Inc the manufacturer warrants to the original owner of any SunStar infrared gas heater that said heater will be free from defects in material or workmanship under norm...

Страница 15: ...is warranty is found to be void unenforceable or unconscionable then the same is hereby severed and the remainder of this warranty is hereby saved and shall remain in force EXCLUSIVE REMEDY The sole and exclusive remedy under this warranty is the replacement of the defective parts or heaters ashereinabovespecified THEMANUFACTURERDOESHEREBYEXPRESSLYEXCLUDEANYANDALL LIABILITYFORINCIDENTALANDCONSEQUE...

Отзывы: