26
②
Set the distance between the needle holder
ⓐ
at the lowest of the needle bar and the upper thread holder
ⓑ
to 0.3mm. This is
the standard. The presser foot is lifted when pressing the pedal backward.
▶
▶
Adjustment order
a. Loosen the fixing nut
ⓒ
.
b. Adjust the distance by moving the presser bar lifting fixed plunger
ⓓ
back and forth.
c. After modifying the width, tighten the fixing nut
ⓒ
.
[ Figure 32 ]
ⓐ
ⓑ
ⓒ
ⓓ
0.3mm
(2) Thread release shaft adjustment
Without pressing the presser bar pedal, set the distance between the thread release pin
ⓐ
and the thread release shaft
ⓒ
to 0mm
when heads of six thread release pins
ⓐ
are at the center of the upper and lower plate of the thread adjusting device plate
ⓑ
.
▶
▶
Adjustment order
a. Loosen the clamp screw
ⓓ
in the presser bar lifting lever(large size).
b. Adjust the thread release shaft
ⓒ
by rotating with a driver.
Tip) The distance becomes narrow when rotating clockwise the thread release shaft, the distance becomes wide when rotating counterclockwise it.
6) PRESSER FOOT PRESSURE MODIFICATION
To make the presser foot pressure lower is better as far as the
sewing material is moved well and the stitch is formed.
Loosen the presser bar adjustment screw nut
ⓐ
and regulate the
presser bar pressure with rotating the presser bar adjustment
screw
ⓑ
then fix it by tightening the nut
ⓐ
.
When rotating the presser bar adjustment screw
ⓑ
clockwise,
the pressure is stronger. When rotating counterclockwise, the
tension is weaker. (Refer to the Figure 34)
[ Figure 34 ]
[ Figure 33 ]
ⓑ
ⓐ
Weak
Strong
[ Figure 31 ]
0mm
ⓐ
ⓑ
ⓒ
ⓑ
ⓐ
ⓓ