33
(2) Assembling order
After assembling in the reverse order of disassembling, adjust the left and right hook base.
[Adjusting the left/right hook base]
When replacing with a wider or narrower gauge than the
needle width in use, the hook edge and needle distance may
not fit correctly. In this case, loosen the screws
①
,
②
,
③
,
④
as can be seen in the picture, and replace the feed dog or
adjust the distance between the hook edge and the needle.
Fasten after making the adjustments.
[Caution]
Turn off the power switch.
1. Remove the right and left slide plates.
3. Disassemble the left and right needle holders
(KM-790 series)
2. Remove the two needles
3. Disassemble the needle holder
(
※
turn it towards the arrowed direction
for removal: KM-750 series)
4. Lift the presser bar lifter to raise the presser foot
5. Remove the presser foot
6. Remove the needle plate
7. Disassemble the feed dog
8. Lay down the sewing machine.
18) Replacing gauge set for needle width
(1) Disassembling order