Form SRH-IOM-1

500011

Residential Garage Heater

Installation, Operation, & Maintenance

Instruction Manual

(Mount a copy of these instructions adjacent to the heater)

MODEL IDENTIFICATION

Record the information from the product identification label here for future reference.

Heater Model No.: _________________________  Heater Serial No.: ________________________

Rating: __________ BTUH   Type of Gas: Nat ___   LP/Propane ___    Date Installed ____________

FOR YOUR SAFETY

IF YOU SMELL GAS:
1. Extinguish any open FLAME.
2. Do NOT try to light any appliance.
3. OPEN windows.
4. Do NOT touch electrical switches; do
    NOT use any telephone in the house.

5. CALL your gas supplier immediately
    from a NEIGHTBOR’S home.  Follow the
    gas supplier’s instructions.
6. IF you can’t reach your gas supplier,
    CALL the FIRE DEPARTMENT.

FOR YOUR SAFETY

Do not store or use GASOLINE or other FLAMMABLE VAPORS or LIQUIDS in the vicinity of
this or any other appliance.

This unit is not to be installed in indoor living/sleeping areas.

!! WARNING !!

THESE INSTRUCTIONS must be carefully read and completely understood BEFORE
attempting to install , operate, or perform maintenance service on this GAS-FIRED
APPLIANCE.  Installation and Service MUST be performed by a QUALIFIED service agency,
installer, contractor, or gas supplier.  Failure to comply with the manufacturer’s instructions can
result in unsafe operation, property damage, personal injury, and/or death.  A gas-fired
appliance can expose you to substances in fuel or from fuel combustion which have been
determined by the State of California to cause cancer, birth defects, or other reproductive
harm.  Contact factory for further information.  Keep these instructions for future reference.

EXPLANATION OF HAZARD INTENSITY LEVELS

DANGER

:  Failure to comply 

WILL

 result in severe personal injury, death, and/or property damage.

WARNING

:  Failure to comply could result in severe personal injury, death, and/or property damage.

CAUTION

:  Failure to comply could result in minor personal injury, and/or property damage.

This manual is to be left with the owner after installation of this unit.

OWNER:  Store this manual in a safe place to furnish your serviceman with the necessary

information for servicing.

QUESTIONS?  Call the SunSpan factory at 1-866-664-3824.

Monday – Friday   8 a.m. to 5 p.m.   Eastern Time

Copyright © 2005, SunSpan

Содержание SRHS-40-10AL

Страница 1: ...ly understood BEFORE attempting to install operate or perform maintenance service on this GAS FIRED APPLIANCE Installation and Service MUST be performed by a QUALIFIED service agency installer contractor or gas supplier Failure to comply with the manufacturer s instructions can result in unsafe operation property damage personal injury and or death A gas fired appliance can expose you to substance...

Страница 2: ...ttached This will cause damage to the controls within the burner requiring them to be replaced If heater is being operated in an atmosphere with a negative pressure or an atmosphere containing contaminants an outside combustion air supply is required Failure to provide outside combustion air may allow excessive heat to back up to the blower wheel and bearings severely shortening service life Corre...

Страница 3: ...ent identification 10 COMBUSTION CHAMBERS HEAT EXCHANGERS components and specifications 11 COMBUSTION AIR SUPPLY application construction dimensions and illustrations 12 EXHAUST VENTING application construction dimensions and illustrations 13 U TUBE INSTALLATION suspension and orientation of U tube heaters 14 U BEND REFLECTOR INSTALLATION exploded view and instructions 15 TUBE ASSEMBLY TIPS helpfu...

Страница 4: ...CSA International formerly A G A and CGA United States A G A Requirement No 7 89 Canada CSA 2 32a M99 GENERAL INSTALLATION GAS CODES Heater must be installed ONLY for use with type of gas appearing on its rating plate United States In the absence of local codes installation must comply with the National Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition Canada In the absence of local codes installat...

Страница 5: ... as possible to the valve train of a commercial or industrial type appliance ELECTRICAL All electric work particularly grounding must conform with all local requirements and United States National Electric Code ANSI NFPA 70 latest edition Canada Canadian Electric Code CSA C22 1 latest edition VENTING Refer to the following standards for proper location sizing and installation of vents as well as i...

Страница 6: ...r on the burner 3 According to section 9 18 2 3 of the National Fuel Gas Code In locations used for storage of combustible materials signs shall be posted to specify the maximum permissible stacking height to maintain required clearances from the heater to combustibles 4 CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES ON THE HEATER AND SHOULD STAY AWAY TO AVOID BU...

Страница 7: ...he space to be heated it is recommended the heater be hung as high as possible and along an uncluttered wall to give the heater s reflector the widest possible view Leave enough space around the burner box to permit future servicing Choose a location allowing easy installation of the vent piping system Each suspension point must be capable of supporting a minimum of 150 lbs 65 kg Allow for heater ...

Страница 8: ...X DUCT 18 IN 46cm LONG WITH 2 HOSE CLAMPS SUPPLY PIPING MUST NOT EXCEED AN EQUIVALENT OF 35 LINEAR FT 10 7m FOR 40 60 MBTUH 11 7 17 6kW NO MORE THAN TWO 90 ELBOWS MAY BE USED A 90 ELBOW IS EQUIVALENT TO 10 LINEAR FT 3m GAS CONNECTION DIAGRAM LOCAL CODES MAY REQUIRE AN ADDITIONAL SHUT OFF COCK BE INSTALLED IN THE GAS LINE AHEAD OF THE DRIP LEG NOTE WHEN GAS PRESSURE EXCEEDS 14 35cm W C A FIRST STAG...

Страница 9: ...IAL FLOW OF HOT GASES OPTIONAL COMMON VENTING THROUGH ROOF OR WALL BOTH HEATERS MUST BE CONTROLLED BY A SINGLE THERMOSTAT 4 x 4 x 5 Y COUPLER 10 x 10 x 13cm OPTIONAL ACCESSORY ADDITIONAL EXHAUST VENT PIPING 4 10 2cm I D SINGLE WALL 26 GA 044cm MINIMUM GALVANIZED SHEET METAL OR OTHER FACTORY APPROVED MATERIALS SEAM TO BE ON TOP NOT SUPPLIED MUST NOT EXCEED AN EQUIVALENT OF 35 LINEAR FT 10 7m FOR 40...

Страница 10: ...20AN SRHS 45 20AL SRHS 50 20AN SRHS 50 20AL SRHS 55 20AN SRHS 55 20AL SRHS 60 20AN SRHS 60 20AL MODEL NO U TUBE HEATERS SRHU 40 15AN SRHU 40 15AL SRHU 40 20AN SRHU 40 20AL SRHU 45 20AN SRHU 45 20AL SRHU 50 20AN SRHU 50 20AL SRHU 55 20AN SRHU 55 20AL SRHU 60 20AN SRHU 60 20AL BURNER EXHAUST END GQC9 GQH6 BURNER GQC9 EXHAUST END BURNER GQC1 GQH1 EXHAUST END BURNER GQC1 GQH1 EXHAUST END U BEND U BEND...

Страница 11: ...m aluminized titanium alloy steel tube 10 ft 3m aluminum reflector 2 hanger brackets 14 ga 21cm aluminized titanium alloy steel tube with turbulator 10 ft 3m aluminum reflector 2 hanger brackets HEAT EXCHANGER COMPONENTS GQH1 40 000 thru 60 000 BTUH 20 foot unit only 11 7 17 6kW 6 1m only GQH6 40 000 BTUH 15 foot unit only 11 7 kW 3 and 4 6m only 16ga 17cm aluminized steel tube with turbulator 10 ...

Страница 12: ... those under a negative pressure combustion air must be taken from outdoors Outdoor air supply may be accomplished by bringing air inside through piping from either the roof or wall as shown below The inlet air roof venting cap roof or inlet air box wall must be located at least 3 three feet 1m away from any vent termination and in a manner preventing blockage by snow Components used to bring in o...

Страница 13: ...all metal pipe to combustible materials throughout the entire length of exhaust vent piping Where a single wall metal pipe passes through a wall roof of combustible material a minimum 2 5 1cm clearance non combustible ventilated metal thimble not supplied MUST be installed in wall roof at the point of passage If thimble is not used all combustible material MUST be removed a minimum of 18 46cm in a...

Страница 14: ...e the combustion chamber as illustrated by the drawings below When radiant tubes are horizontal reflectors except at the U bend may be individually rotated from 0 to 45 degrees NOTE the U bend reflector cannot be rotated HORIZONTAL ANGLED BASIC SUSPENSION ARRANGEMENT U BEND REFLECTOR REQUIRED 0 DEGREES 1 45 DEGREES DO NOT EXCEED 7 5 IN 19cm ...

Страница 15: ...s Item no 6 over U bend Item no 2 2 Install Items no 4 5 and 6 onto the pipe hanger s stud 3 Place U bend reflector assembly Item no 1 over studs 4 Install Items no 4 5 and 6 over the stud on top 5 Position U bend with reflector assembly into combustion chamber and heat exchanger up to the colored indicators 6 Use 4 four 12 multi metal self drilling screws supplied with U bend to fasten U bend to ...

Страница 16: ...END EXHAUST END markings on the combustion and exhaust end tubes 2 Position a 2X4 in 5x10 cm block of wood on each of the far ends of both tubes One block of wood prevents damage to the connecting end that will be used to tap that tube into the other The other block of wood prevents damage to the other connecting end that is butted up to a nearby sturdy wall ALL WELD SEAMS MUST BE LINED UP TOGETHE...

Страница 17: ...ht and level with the weld seam on top before installing the screws Drive with a power tool the two 2 12 MULTI METAL Tek screws into the joint and position the four 4 hangers on the twenty 20 foot 6 1m section 5 Attach a temporary rope or chain to the two 2 outer brackets and hoist the twenty 20 foot 6 1m section into the air Align the weld seam on top level the section and install the chain on th...

Страница 18: ...ber and the burner Install tube reflector hangers Slip one end of the S hook through the last chain link and the other end through the tube reflector hanger IMPORTANT Crimp both ends of the S hook closed STEP 3 Identify all components in COMBUSTION CHAMBERS and HEAT EXCHANGERS sections of this manual Check the BASIC SYSTEM CONFIGURATIONS section of this manual for the general orientation of compon...

Страница 19: ...gh the two holes provided in the flared end with 2 two 12 MULTI METAL Tek screws supplied with the tube Place a reflector over the heat exchanger and into the suspended hanger bracket assemblies STEP 7 Slip the burner s tube into the burner coupler previously installed in Step 4 Once the burner is level straight and inserted against the center stop use 2 two 12 MULTI METAL Tek screws supplied with...

Страница 20: ...tric Code ANSI NFPA 70 or local code legally authorized Electrical power takeoff must be connected to a separately fused circuit with a disconnect or a circuit breaker and must be properly polarized and grounded to the heaters power cord Do not run wiring over the heaters or in direct view of radiant heat If any of the wiring supplied must be replaced use type 16 AWG 1 0mm 2 or equivalent with 2 6...

Страница 21: ...l IDC is turned on and begins a 15 second pre purge time period The pre purge period is followed by a 15 second trial for ignition during which a spark is developed at the igniter and the gas valve is opened to the first step of its two step operation Burner ignites and 5 seconds later the gas valve steps up to its operating position DC electrical current flows from sensing electrode through flame...

Страница 22: ...ater SEE CAUTION LAZY LOOP Use swing or swivel joint in addition to rigid piping if local codes prohibit use of a flexible connector Local codes may require additional shut off cock ahead of the drip leg Gas pressure at test point A inlet pressure to the burner s gas valve cannot be more than 14 inches of water column in WC 35 6cm WC 1 2 PSI confirmed by actual field test Heater on or off CAUTION ...

Страница 23: ...ction Depress the dial on the gas valve and make sure the gas valve is in the ON position Turn on the electrical and gas supply and set the thermostat above the ambient room temperature to call for heat Refer to the ELECTRICAL SUPPLY AND THERMOSTATIC CONTROL section for proper sequence of operation If the heater does not operate normally refer to the BURNER TROUBLESHOOTING section to diagnose and ...

Страница 24: ...ostat and wiring Find problem and correct it Is the power supply to heater 115 VAC Replace blower NO YES NO Is the power supply to the heater fused YES Replace fuse Energize the system YES Disconnect flex hose at each heater until gas is present Connect flex hose and leak test NO Have all gas lines been completely bled of air Is this a new installation YES NO Were heaters isolated during high pres...

Страница 25: ...n the on position Turn gas valve to the on position Is there 115 VAC coming from the IDC box Is there 115 VAC at the gas valve Replace gas valve Replace gas valve Replace the IDC box YES NO NO YES YES NO NO YES YES Does the burner stay lit until the thermostat is satisfied TROUBLESHOOT ENDS YES NO Is the outlet manifold gas pressure correct see serial plate Is the power supply grounded to a true e...

Страница 26: ...nd the inlet air collar are properly attached Check that the blower can come up to full speed Remove the cover by removing the 4 sheet metal screws on top of the cover Remove the ignitor by removing ONLY the end where the vinyl tubing is attached to the ignitor bracket the fitting to which the vinyl tubing was connected the ignition lead wire from the ignition detection control and the sheet metal...

Страница 27: ...ubber and fittings 18 Burner tube holding bracket with screws 8 Air flow switch 19 Wire harness assembly 9 Burner cover 20 Gas manifold fitting at valve 10 Inlet combustion air collar 21 Gas sub orifice 11 Air orifice plate 22 Gas main orifice located inside of burner tube WARNING Any substitutions of factory installed parts without prior written permission may result in unsafe operation property ...

Страница 28: ...___________________ ________________________________________________________ Phone __________________________________________________ SECOND Contact the Nearest Distributor Model No ______________________________________________ Unit Serial No ___________________________________________ Date of Installation ________________________________________ P O Box 80217 Rochester MI 48308 0217 Toll Free 1 ...

Отзывы: