41
ERROR CODES
The operation panel can display 2 error codes:
1. Temperature/ glass seal error code (a beep sounds
for 10 sec + LED lamps flash quickly for 10 sec). The
glass pane is not closed properly, is broken, removed
or the Sunshower has overheated. PLEASE NOTE: The
Sunshower is no longer waterproof if the glass pane
is missing! Switch off the Sunshower completely by
switching off the relevant ground fault circuit breaker in
the meter box and contact your supplier or Sunshower directly:
www.sunshower.nl.
2. Replacing UV lamps
At the start of the UV session 5 LED lamps flash
alternatively. This occurs after 600 hours of operation,
this means that the capacity of the lights has reduced
and it is recommended to replace these. You can
continue to make use of the Sunshower by pressing the
UV button once more. Also refer to the REPLACING
THE LAMPS chapter.
Other malfunctions
• Sunshower does not start properly with UV session
If the UV lamps are still warm from an UV (or IR) session, they cannot be
immediately restarted. It is therefore important that the Sunshower fully com-
pletes the cooling period following a session, also after an IR session. If this is
not the case, please wait for 15 minutes before you start another UV session.
• Sunshower drops out during UV session
The gas-discharge lamps are sensitive to dips in the mains voltage (longer than
10ms), where the Sunshower can drop out during an UV session. If this hap-
pens, press the Stop button and allow the UV lamps to cool. The session can
be resumed when the cooling period is over.
10 Sec
Содержание COMBI WHITE
Страница 1: ...1 SUNSHOWER COMBI WHITE HANDLEIDING MANUAL ANLEITUNG MODE D EMPLOI...
Страница 2: ...2...