10:3
ST PS
Sunrise Training and Education Programmes
CHAPTER TEN
PROGRAMMING
Programming
Parameter List
GENERAL SETTINGS
CONT.
MAX
MIN
REVERSE ALARM
ON
PULSED REVERSE ALARM
ON
DIAGNOSTIC ALARM
ON
BRAKE DISCONNECTED ALARM
OFF
BRAKE FAULT DETECT
ON
BRAKE LIGHT
OFF
FREEWHEEL SPEED LIMIT
100
FREEWHEEL TIME OUT (0.1Sec.)
2
FREEWHEEL ENABLE
ENABLE
MOTOR SETTINGS
CURRENT LIMIT MAX
45A
BOOST DRIVE CURRENT
45A
BOOST DRIVE TIME (Sec.)
0
CURRENT FOLDBACK THRESHOLD
30A
CURRENT FOLDBACK TIME (Sec.)
20
CURRENT FOLDBACK LEVEL %
90
MOTOR COOLING TIME (Sec.)
120
CURRENT FOLDBACK TEMP. ( C )
80
CURRENT LIMIT MIN
10A
MOTOR COMPENSATION (mΩ)
210
ANTI ROLLBACK LEVEL
12
PULL-AWAY DELAY (0.1 Sec)
30
SLOPE FACTOR
90
ANTI ROLLBACK VELOCITY
0
FACTORY SETTINGS
ACCELERATION (0.1 Sec)
100
1
DECELERATION (0.1 Sec)
100
1
FORWARD SPEED %
100
0
REVERSE SPEED %
100
0
THROTTLE SETTINGS
THROTTLE TYPE
1 (WIGWAG)
THROTTLE DEADBAND %
10
THROTTLE GAIN %
110
THROTTLE OPERATED AT POWER UP
2 (TRIP)
THROTTLE REFERENCE TEST
ON
ISO TEST RESISTOR
OFF